In the configuration of the host computer, the radio address, frequency channel, network ID, and key are all
displayed in decimal mode. The range of each parameter is:
Network address: 0
~
65535
Frequency channel: 0
~
83
Network ID: 0
~
255
Key: 0
~
65535
When using the host computer to configure the relay mode, the user needs to pay special attention. Since the
parameters in the host computer are in decimal display mode, the radio address and network ID need to be
converted when filling in the radio station address and network ID. If the network ID input by the transmitting
terminal A is 02 and the network ID input by the receiving terminal B is 10, when the relay terminal R sets the radio
address, the hexadecimal value 0X020A is converted to the decimal value 522 as the relay terminal R. Radio
address. That is, the radio address value that needs to be filled in by the relay terminal R at this time is 522.
10 Program the Radio
Operating mode
M1
M0
注释
Configuration mode
The indicator light is on
The indicator light is off
Only use the configuration software to
program the radio in the current mode
1. Programming can only be carried out in a specific working mode (see the above table). If the programming fails,
please confirm whether the working mode of the radio is correct.
2. If you don't need complicated programming to open the E96-DTU (400SL30-485) configuration software, you can
modify the relevant parameters.