Chengdu Ebyte Electronic Technology Co., Ltd.
Copyright ©2012–2019
,
Chengdu Ebyte Electronic Technology Co., Ltd.
20
9. Configuration instructions on computer
9.1 Configuration considerations
(1) after the data transmission station is powered on, there is a self-test time of 3 seconds. During the self-test time,
the status light appears blue and flashes rapidly. At this time, use the configuration software to search for the device and
connect the device to the computer, and the device will enter the configuration mode (the status light appears blue and
flashes once in 1 second). Parameters can be modified by configuration software.
Note: how to establish a connection and enter configuration mode for configuration? Please see 2. Quick start
(2) If no connection is established within the 3 second self-test time, the radio will enter the working mode after the
self-test time, the digital radio status light will show different colors according to different working modes, and the
configuration software cannot search at this time. device. If you need to reconfigure, you can only reconnect the power,
so that the device enters the configuration mode in the self-test state.
9.2 Factory default parameters
model
Frequency
Address
Channel
Air Rate
Baud Rate
Serial
Format
Transmit
Power
E90-DTU
(400SL22P)
433.125MHz
0x0000
0x23
2.4kbps
9600
8N1
1W
9.3 Configuration software and parameter description
The following figure shows the display interface of the host computer with E90-DTU configuration.
No.
Name
Description
1
Information Bar
Display basic information of the
connected station
2
Connection area
Used to select a serial port to establish
a connection and switch between
Chinese and English
3
Function switching bar
Used to switch between 3 main
configuration functions
4
Configure the ribbon
Used to read and configure parameters
5
Status Bar
Display status information