background image

Chengdu Ebyte Electronic Technology Co., Ltd.

E90-DTU(400SL22P)User Manual

Copyright ©2012–2019

Chengdu Ebyte Electronic Technology Co., Ltd.

2

1. Introduction

1.1 Brief introduction

E90-DTU (400SL22P) is a true high-quality industrial-grade wireless digital radio. The power supply supports

3-level protection, RS485 and RS232 support 4-level protection, and the RF port supports 4-level ESD protection. It can
be used in industrial applications where the electromagnetic environment is more complicated. The radio adopts LORA
spread spectrum technology, and its powerful anti-interference ability makes wireless communication more stable and
reliable in the industrial field.

It has multiple transmission modes, working in the (410.125 ~ 493.125MHz) frequency band (default 433.125MHz),

the radio provides transparent RS232/RS485 interface, supports 8 ~ 28V voltage input. LoRa direct-sequence spread
spectrum technology will bring longer communication distances, and has the advantages of concentrated power density
and strong anti-interference ability. The module has a software FEC forward error correction algorithm, which has high
coding efficiency and strong error correction capability. In the case of sudden interference, it can actively correct the
interfered data packets, greatly improving reliability and transmission distance. In the absence of FEC, such packets can
only be discarded. The radio has data encryption function, and the data transmitted by the radio in the air has randomness.
The data interception is meaningless through strict encryption and decryption algorithms; the packet length setting is
supported, and different real-time and data packets are supported.

As a communication medium, wireless digital radio has the same scope as optical fiber, microwave and bright line:

it provides real-time and reliable data transmission of monitoring signals in private networks under certain special
conditions, with low cost and installation and maintenance. Convenient, strong diffraction ability, flexible network
structure and long coverage. It is suitable for multi-point and location dispersion, complex geographical environment, etc.
It can be connected with PLC, RTU, rain gauge, liquid level meter and other data terminals.

1.1.1 Certificate

E90-DTU is certified with CMIIT ID:2017FP5780 by SRRC.

E90-DTU is certified with “Certificate of conformity on explosive application protection”

ID:

201711000975.

E90-DTU is certified with

“Electrostatic surge test report” by National Institute of Measurement and Testing

Technology

ID

CNEx18.1461.

E90-DTU is certified with “Certificate of Design Patent”

Patent Number

ZL 2016 3 0501980.3.

E90-DTUis certified with “Utility model patent certificate”

Patent Number

ZL 2016 2 1410691.3.

E90-DTU is certified with “CE” , ID

CCISE180514601V.

E90-DTU is certified with “FCC”, ID

2ALPH-E90-DTU.

E90-DTU is certified with “RoHS”

ID

DTI201807025245.

Summary of Contents for 400SL22P

Page 1: ...Chengdu Ebyte Electronic Technology Co Ltd E90 DTU 400SL22P User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd E90 DTU 400SL22P ...

Page 2: ...IFO and sub packing method 14 6 Function Description 15 6 1 Fixed Transmission Hexadecimal 15 6 2 Broadcast Transmission Hexadecimal 15 6 3 Broadcast Address 16 6 4 Monitor Address 16 7 Operating mode 16 7 1 Normal mode Mode 0 16 7 2 WOR sending mode Mode 1 16 7 3 WOR receiving mode Mode 2 17 8 Relay networking mode 18 9 Configuration instructions on computer 20 9 1 Configuration considerations 20...

Page 3: ...sence of FEC such packets can only be discarded The radio has data encryption function and the data transmitted by the radio in the air has randomness The data interception is meaningless through strict encryption and decryption algorithms the packet length setting is supported and different real time and data packets are supported As a communication medium wireless digital radio has the same scop...

Page 4: ...ess rate of the module in harsh environments is greatly improved Remotely configure or read wireless module parameters by sending command packets wirelessly Support communication key function to effectively prevent data from being intercepted Multi level relay networking can be realized which effectively extends communication distance for ultra long distance communication With temperature compensa...

Page 5: ...h power DTUs should be more than 1 meter otherwise it may cause damage 1 First install the antenna for the digital radio station and then use USB to RS 232 or USB to RS 485 to connect the computer to the digital radio station The computer opens the host computer software selects and opens the serial port and clicks to search for the device at this time the host computer The status bar shows Establ...

Page 6: ...ser Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 5 2 Then plug in the radio power and the device will automatically connect with the host computer the status bar of the host computer will display The configuration connection is successful ...

Page 7: ...tablished you can use the host computer to configure the parameters of the radio or remotely configure other module radios Please read the parameters before configuration After selecting the parameters that need to be set and clicking the write parameter button the parameters can be written into the radio and it will take effect after exiting the configuration mode ...

Page 8: ...Chengdu Ebyte Electronic Technology Co Ltd E90 DTU 400SL22P User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 7 ...

Page 9: ...adio will exit the connection and work according to the set working mode and parameters no need to restart the radio 4 Communication test start two serial port debugging assistants select the serial port baud rate and verification method that are consistent with the radio parameters and then realize the serial port transparent transmission note the parameters of the two radios need to be set the s...

Page 10: ...Chengdu Ebyte Electronic Technology Co Ltd E90 DTU 400SL22P User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 9 ...

Page 11: ...Chengdu Ebyte Electronic Technology Co Ltd E90 DTU 400SL22P User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 10 3 Dimensions 3 1 Parts description ...

Page 12: ...power input negative Power reference ground 5 DC IN Crimping power input positive Power input 6 DC IN stand DC socket 5 5 2 1mm Power input 7 PWR LED Power Indicator Red lit when the power is on 8 TX RX LED Data sending and receiving indicator Green blinking when sending data Blue blinking when receiving data 9 MODE LED Status Indicator Cyan light on transparent transmission mode Blue light on WOR...

Page 13: ...ly from both are optional It can also be powered by VCC terminal and GND terminal just choose any one of the power supply modes 8 28V DC power supply it is recommended to use 12V or 24V DC power supply for E90 DTU 4 2 RS232 The E90 DTU can be connected to the device via RS 232 using the standard DB 9 interface 4 3 RS485 E90 DTU can use 485_A terminal and 485_B terminal to connect RS 485 A terminal...

Page 14: ...ion 5 1 Model specification Model No Frequency TX power Distance Features Recommended application Hz dBm km E90 DTU 400SL22P 433 125M 22 5 LoRa anti interference Suitable for transmission of fast speed in complex environment with data interference over a long distance Note Test condition in clear and open air without shelters 12V 2A power supply 5dBi gain sucker antenna over 2 meters height from t...

Page 15: ...ir data rate Model Default Levels Air data rate bps bps bps E90 DTU 400SL22P 2 4k 8 0 3 1 2 2 4 4 8 9 6 19 2 38 4 62 5k Note The higher the air data rate the faster the transmission rate the transmission distance is also closer when the rate meets the requirements the lower air data rate the better quality 5 6 Current Model No Tx current mA Stand by current mA 12V 24V 12V 24V E90 DTU 400SL22P 88 4...

Page 16: ...ctronic Technology Co Ltd 15 6 Function Description 6 1 Fixed Transmission Hexadecimal During fixed point transmission the module recognizes the first three bytes of the serial data received as Address high address low channel and use it as a wireless transmission target 6 2 Broadcast Transmission Hexadecimal ...

Page 17: ...general mode mode 0 the factory default setting is the general mode Mode 0 Categories Notes Mode 0 Normal Mode Serial port open wireless open transparent transmission factory default mode support special command air configuration Mode 1 Wor sending mode WOR sender Mode 2 WOR receiving mode WOR receiver Note if there is no need for low power consumption there is no need to care about the wor receiv...

Page 18: ...yte Electronic Technology Co Ltd 17 7 3 WOR receiving mode Mode 2 Type Software configuration module working in mode 2 Transmitting Wireless transmission off Receiving Sleep at ordinary times Periodically wake up to check whether there is data If there is data receive it and enter sleep after processing ...

Page 19: ...work rules 1 Forwarding rules The relay can forward data in both directions between two NETIDs 2 In relay mode ADDH ADDL is no longer used as the module address and is forwarded and matched as NETID 3 In the relay mode please do not send more than the set single packet sub byte As shown in the figure Primary relay Node 1 has a NETID of 08 Node 2 has a NETID of 33 ADDH ADDL of relay 1 is 08 and 33 ...

Page 20: ... computer is a decimal display mode the module address and network ID need to be converted when filling in For example if the network ID entered by the transmitting end A is 02 and the network ID entered by the receiving end B is 10 when the relay end R sets the module address it will convert the hexadecimal value 0X020A to a decimal value 522 as the relay end R to fill Module address That is the ...

Page 21: ...enter the working mode after the self test time the digital radio status light will show different colors according to different working modes and the configuration software cannot search at this time device If you need to reconfigure you can only reconnect the power so that the device enters the configuration mode in the self test state 9 2 Factory default parameters model Frequency Address Chann...

Page 22: ...rs 2 Remote configuration See Figure 2 below It is used to remotely configure or read the parameters of other radio stations or E22 modules The configured radio stations or modules are required to be in transparent transmission mode and enabled by wireless configuration Consistent with own station Immediately after configuration 3 RSSI real time monitoring Note During remote configuration if the a...

Page 23: ...Chengdu Ebyte Electronic Technology Co Ltd E90 DTU 400SL22P User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 22 Local configuration ...

Page 24: ...Chengdu Ebyte Electronic Technology Co Ltd E90 DTU 400SL22P User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 23 Remote configuration ...

Page 25: ...Chengdu Ebyte Electronic Technology Co Ltd E90 DTU 400SL22P User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 24 RSSI real time monitoring ...

Page 26: ...selection Transparent mode default Sending The user can input data through the serial port and the module will start transmitting these data wirelessly Receiving After receiving the wireless data the module will output these data through the serial port TXD pin WOR send mode Sending The wake up code will be automatically added for a certain period of time before transmitting Receiving Receive func...

Page 27: ...g data 8 Relay enable Off default turn on After the relay function is enabled if the target address is not the module itself the module will start a forwarding To prevent data from being transmitted back it is recommended to use it in conjunction with fixed point mode that is the destination address and the source address are different 9 Module address Input range 0 65535 default 0 Address of the ...

Page 28: ...ngth turn on The data sent by the user is less than the length of the sub packet and the serial port output of the receiving end appears as an uninterrupted continuous output The data sent by the user is longer than the packet length and the serial port on the receiving end will be packetized and output Input range 0 83 default 23 0 3 Kbps 1 2 Kbps 19 transfer method 2 4 Kbps default Sending The u...

Page 29: ... 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 28 0 65535 default 0 none Used for encryption to avoid interception of wireless data in the air by similar modules The module will use these two bytes as a calculation factor to transform and encrypt the airborne wireless signal ...

Page 30: ...td 29 10 Programming the modem 10 1 Connection diagram 1 Configuration can only be performed within 3 seconds after power on If it fails please confirm whether it has entered configuration mode 2 If no complicated programming is needed to open the E90 DTU SL digital radio configuration software you can modify the relevant parameters ...

Page 31: ...Chengdu Ebyte Electronic Technology Co Ltd E90 DTU 400SL22P User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 30 11 Connection diagram in test and practical application ...

Page 32: ...ing transmission long distance anti inference E90 DTU 900SL 30 RS232 RS485 868 915M 1 10 LoRa wireless configuration networking transmission long distance anti inference E90 DTU 170L3 0 RS232 RS485 170M 1 8 LoRa super strong penetration diffraction E90 DTU 433L3 0 RS232 RS485 433M 1 8 LoRa long distance anti interference E90 DTU 433L3 7 RS232 RS485 433M 5 20 LoRa 20km ultra long distance anti inte...

Page 33: ...home Internet of things transformation power load monitoring distribution network automation hydrological and hydrological forecasting water pipe network monitoring urban street lamps Monitoring air defense alarm control railway signal monitoring centralized control of railway water supply oil supply pipe network monitoring GPS system remote meter reading electronic crane automatic reporting seism...

Page 34: ...ield or dusty environment Do not let the data transceiver continuously be in full load transmission state otherwise the transmitter may be burned out The ground wire of the data transceiver should be well connected with that of the external equipment such as PC PLC etc and of the power supply Otherwise it is easy to burn the communication interface do not plug or unplug the serial port when electr...

Page 35: ...ued by 1 0 Initial version 1 1 2019 12 12 Format revision Ren About us Technical support support cdebyte com Documents and RF Setting download link www ebyte com Thank you for using Ebyte products Please contact us with any questions or suggestions info cdebyte com Official hotline 028 61399028 Web www ebyte com Address Innovation Center B333 D347 4 XI XIN Road Chengdu Sichuan China ...

Reviews: