CPX200NWB ALARM CONTROL UNIT – INSTALLER MANUAL
31 / 118
Examples:
a)
change of a single parameter – assigning 1, 2, 3 zones to the first partition:
b)
change of a single parameter – assigning 1, 10, 11 zones to the second partition:
(long press)
(long press)
c)
change of time for leaving both partitions into 60 seconds:
d)
change of many parameters at the time for partition 2 using complex function –
zones 2, 4, 5 and output 1 to belong to partition 2, time for leaving the one to be
45 seconds, alarm time in partition 2 to be 120s and signalling of time for entering
and leaving was quiet:
… …
4.3.9.
Wireless zones configuration
4.3.9.1.
Wireless sensors configuration
Wireless zones can be configured using complex service functions, after activation of which,
all the parameters related to the relevant zone can be given subsequently or in a form of
series of service functions that configure one zone-related parameter. Codes of zone
configuration functions are defined as per the following pattern:
<XX> <Y>
Where:
XX –
determines the number of wireless zone from
01
to
16
; entering number
00
will
change the parameters for all zones in the system,
Y –
number of parameter related to a given zone:
Note:
In case of complex function (programming many
parameters at the time) after the parameter is entered and confirmed
with
,
the parameter is saved in the configuration memory and
the system waits for entering another parameter, and so on, until all
parameters of the complex service function are entered. Press
to
cancel changes entered in currently configured parameter only and
exit service function – previously entered parameters, confirmed with
,
will not be cancelled.