CPX200NWB ALARM CONTROL UNIT – INSTALLER MANUAL
32 / 118
0
– complex function, the initiation of which configures the parameters listed below
as another set of parameters:
1
– Delete a sensor. After selecting this option, you can confirm deleting by pressing
key, or you can cancel function by pressing
key.
2
– Add a sensor. After selecting this option, the sabotage button on the sensor has
to be pressed. Once the transmission with the sensor is established, its serial number
will be displayed on the keypad (hexadecimal value). If accepted, the sensor will be
saved.
3
– Type of a wireless sensor (read only):
o
0 – no sensor
o
1 – PIR-10 sensor
o
2 – MC-10 sensor
o
3 – GS-10 sensor
o
4 – SD-10 sensor
o
5 – PIR-11 sensor
Note: During the adding a new wireless detector (function 2), the front cover of the detector
should be removed. It is recommended to add wireless sensors individually. To prevent the
accidental transmissions from other detectors, only one detector cover should be removed
during the procedure of adding a new detector.
Example:
a)
delete a wireless sensor no. 10:
b)
add a wireless sensor no. 11:
4.3.9.2.
Signal strength of wireless detectors
The function allows to check signal strength of wireless detectrors.
LEDs 1 – 16 indicate line with wireless detectors.
Enter the line number and press
to confirm. LEDs 1 – 8 will display signal strength
from selected wireless detectors. No lighted LEDs indicates no signal.
1 LED – 12% signal strength
2 LEDs – 25% signal strength
3 LEDs – 37% signal strength
4 LEDs – 50% signal strength
5 LEDs – 62% signal strength
6 LEDs – 75% signal strength
7 LEDs – 88% signal strength