EBS
Ink Jet Systems
EBS-1500
Series Printers User's Manual
Paragraph 4 - Operating the Printer
20060920#3.1
67
The menu branches mentioned above can be protected with a user password. If
the user forgets the password, the protection can be released by
cancelling the
user password.
2)
An operation time limit assigned to a user by the manufacturer (or distributor
under a separate agreement). When the limit expires, the printer stops working
automatically. Then the printer stops responding to user commands. Only the
release protection command can be executed. The assigned time limit can be
prolonged by 50, 100 or 200 hours, or possibly the limit can be cancelled and the
unit released from any operational constraints.
In the main MENU select the
AUX. COMMANDS
item and then the
UNLOCK PROTECTION
item.
In order to get the protection released, contact the Manufacturer (distributor) by
telephone and describe what kind of protection is to be released.
After the
UNLOCK PROTECTION
command has been selected, a nine-digit code is
displayed in the operating window on the terminal. The code is used to calculate the
password.
Reveal the code to the Manufacturer representative but do not exit the command or
press any key (especially the printer switch-off key). You will be given a coded
password to release the protection. Type the coded password and press the
V
key. If you make a mistake or type in a wrong code, the device enables you to input
the code ten times before you will have to contact the manufacturer or your
distributor. After ten unsuccessful attempts the message
Switch the PRINTER off and on
is displayed and the protection remains enabled.
If the proper code is typed in, the printer confirms this fact by displaying the
**OK**
message and the user-indicated security feature is disabled.
NOTE:
If the user had to exit the command while waiting for a return code and has now
repeated the command
UNLOCK PROTECTION
, then the code obtained will be
invalid and will not help release the protection. Only a return code entered properly
soon after the original code, while the
UNLOCK PROTECTION
command is active,
will allow the protection to be released.
!