EBS
Ink Jet Systems
EBS-1500
Series Printers User's Manual
Paragraph 4 - Operating the Printer
20060920#3.1
43
In this mode the
Spc.Md.max
,
Spc.Md.cnt
and
Pal.countr
parameters are not available and
their values cannot be set.
EXAMPLE 1:
Creating a standard pallet counter.
Assumptions
: Packages moving on a factory conveyor are stored on a pallet in single
layers, with 4*5=20 packages in each layer. Packages are placed on the pallet in
A
and
B
order and directions, as shown in the illustration. The pallets are put one onto the other in
4 layers (
C
) on every shelving in the store. The packages need to be labelled in such
a way that the pallet number and consecutive package number are printed on each pallet.
When the printing is interrupted and then resumed, the consecutive number is printed.
After 4 pallets (80 packages) have been labelled, the counter should be reset (i.e. set to
its minimum setting) and the counting resumed.
The text file to be printed contains a special register, that is a
universal counter
and the
text
000/000
typed via the keypad. Set the counter parameters to the following
settings:
Print beg.
=
CONTINUE
,
Mode
=
Standard
,
Beg.value1
=1,
Min.value1
=1,
Max.value1
=4,
Cnt.delta1
=1,
Beg.value2
=1,
Min.value2
=1,
Max.value2
=20,
Cnt.delta2
=1,
Cnt.value2
=1,
0 suppress
=
NO
The following numbers are printed with the above settings:
001/001, 001/002, ... , 001/020, 002/001, 002/002, ... , 002/020, 003/001, ...... , 004/019,
004/020, 001/001, etc.
NOTE
: If the numbering of packages has been disturbed for some reason during the
printing, the printing can be stopped, the
Print beg.
parameter can be reset to
BEG.VALUE
, both counters can be reset to their initial settings (
Beg.value1
and
Beg.value2
) and the printing can be resumed.
000/ 000
000/ 000
000/ 000
001/ 001
000/ 000
000/ 000
000/ 000
001/ 005
000/ 000
000/ 000
000/ 000
001/ 009
000/ 000
000/ 000
000/ 000
001/ 013
000/ 020
000/ 019
000/ 018
001/ 017
000/ 000
000/ 000
000/ 000
002/ 001
000/ 000
000/ 000
000/ 000
002/ 005
000/ 000
000/ 000
000/ 000
002/ 009
000/ 000
000/ 000
000/ 000
002/ 013
000/ 020
000/ 019
000/ 018
002/ 017
000/ 000
000/ 000
000/ 000
003/ 001
000/ 000
000/ 000
000/ 000
003/ 005
000/ 000
000/ 000
000/ 000
003/ 009
000/ 000
000/ 000
000/ 000
003/ 013
000/ 020
000/ 019
000/ 018
003/ 017
000/ 000
000/ 000
000/ 000
004/ 001
000/ 000
000/ 000
000/ 000
004/ 005
000/ 000
000/ 000
000/ 000
004/ 009
000/ 000
000/ 000
000/ 000
004/ 013
000/ 020
000/ 019
000/ 018
004/ 017
Order A, B and direction in which
packages are stored on pallets
A
B
C
1
2
3
4
1
st
pallet
2
nd
pallet
3
rd
pallet
4
th
pallet
1 2 3
4
5
Direction in
which pallets
are placed
000/ 000
000/ 000
000/ 000
001/ 001
000/ 000
000/ 000
000/ 000
001/ 005
000/ 000
000/ 000
000/ 000
001/ 009
000/ 000
000/ 000
000/ 000
001/ 013
000/ 020
000/ 019
000/ 018
001/ 017
1
st
pallet 2
nd
shelving
1
st
shelving
Fig. 4.4.1.10.1.
The operation of the universal counter used in Example 1
2)
Universal counter with the parameter
Mode
=
Special
.
Additional parameters of the universal counter are available in this mode. They are
Spc.Md.max
,
Spc.Md.cnt
and
Pal.countr
– see the table above. With them the
numbering of products can be automated so that the subsequent packing and storing