background image

Operating instructions

W3G300-BV25-82

Translation of the original operating instructions

3.2 Nominal data

Motor

M3G084-BF

Nominal voltage / VDC

26

Nominal voltage
range / VDC

16 .. 32

Method of obtaining
data

fa

Speed (rpm) / min

-1

3350

Power consumption / W

230

Current draw / A

9

Min. ambient
temperature / °C

-40

Max. ambient
temperature / °C

85

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Data according to Commission Regulation (EU) 327/
2011

Actual

Req. 2015

01 Overall efficiency η

es

/ %

44.4

30.6

02 Measurement category

A

03 Efficiency category

Static

04 Efficiency grade N

53.8

40

05 Variable speed drive

Yes

06 Year of manufacture

The year of manufacture is specified on the
product's rating label.

07 Manufacturer

ebm-papst Mulfingen GmbH & Co. KG
Amtsgericht (court of registration) Stuttgart ·
HRA 590344
D-74673 Mulfingen

08 Type

W3G300-BV25-82

09 Power consumption P

e

/ kW

0.32

09 Air flow q

v

/ m³/h

1795

09 Pressure increase total p

fs

/

Pa

260

10 Speed (rpm) n / min

-1

3345

11 Specific ratio

*

1.00

12 Recycling/disposal

Information on recycling and disposal is
provided in the operating instructions.

13 Maintenance

Information on installation, operation and
maintenance is provided in the operating
instructions.

14 Additional components

Components used to calculate the energy
efficiency that are not apparent from the
measurement category are detailed in the
CE declaration.

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Data obtained at optimum efficiency level. The efficiency values displayed for achieving

conformity with the Ecodesign Regulation EU 327/2011 has been reached with defined air

duct components (e.g. inlet rings). The dimensions must be requested from ebm-papst. If

other air conduction geometries are used on the installation side, the ebm-papst evaluation

loses its validity/the conformity must be confirmed again. The product does not fall within

the scope of Regulation (EU) 2019/1781 due to the exception specified in Article 2 (2a)

(motors completely integrated into a product).

3.4 Technical description

Weight

2.3 kg

Size

300 mm

Motor size

84

Blade material

PA plastic UL94 V0

Fan housing material

PA plastic UL94 V0

Number of blades

7

Airflow direction

V

Balancing grade
according to DIN ISO
21940-11

G 10

Direction of rotation

Clockwise, viewed toward rotor

Degree of protection

Motor IP24 KM, electronics IP6K9K
(mating connector installed)

Insulation class

"B"

Moisture (F) /
Environmental (H)
protection class

H3

Installation position

Any

Condensation
drainage holes

None, open rotor

Mode

S1

Motor bearing

Ball bearing; (sealed)

Technical features

- Lowering input
- Error output (high-side switch)
- INVLIN (inverse linear control input)
- Power limiter
- Load dump (58 V)
- Motor current limitation
- Soft start
- Control input 0-10 VDC / PWM
- Temperature derating
- Overvoltage detection
- Thermal overload protection for
electronics
- Line undervoltage detection
- Reverse polarity protection

Electrical hookup

Connector with cable; Standby current
less than 500 µA

with cable

Lateral

Protection class
assignment

III; Requires supply with safety extra-
low voltage SELV.
This component for installation may
have several local protection classes.
This information relates to this
component’s basic design.
The final protection class is based on
the component’s intended installation and
connection.

Conformity with
standards

EN 45545-2, HL3; EN 50155; EN
61373, Cat. 1B

Approval

EAC

;

Use the device in accordance with its degree of protection.

Item no. 53944-5-9970 · ENU · Change 265422 · Approved 2022-08-19 · Page 5 / 11

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for W3G300-BV25-82

Page 1: ...se used by suitably qualified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules The safety hazards associated with the device must be assessed again following installation in the final product The locally applicable industri...

Page 2: ...ropriate shielding measures have to be taken by the user NOTE Electrical or electromagnetic interference after installing the device in customer equipment Verify that the entire setup is EMC compliant 1 7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller Secure the device against accidental contact Before working on the syste...

Page 3: ...the device in the following ways is prohibited and could be hazardous Operating the device in an unbalanced state e g due to dirt deposits or ice formation Resonant operation operation with severe vibration This also includes vibration transmitted to the fan from the customer installation Operation in medical equipment with a life sustaining or life support function Conveying solids in the flow me...

Page 4: ...05 1 4x seal TE 828904 1 1 1 UB 1 2 GND 1 3 PWM LIN 1 4 not used 1 5 not used 1 6 Diagnostic output Accessory part Cable 460 mm with mating connector part no 02002 4 1021 not included in scope of delivery 6 pole mating connector TE 1 963212 1 4x receptacle TE 929939 1 2x receptacle TE 929937 1 2 Airflow direction V Item no 53944 5 9970 ENU Change 265422 Approved 2022 08 19 Page 4 11 ebm papst Mulf...

Page 5: ...ion geometries are used on the installation side the ebm papst evaluation loses its validity the conformity must be confirmed again The product does not fall within the scope of Regulation EU 2019 1781 due to the exception specified in Article 2 2a motors completely integrated into a product 3 4 Technical description Weight 2 3 kg Size 300 mm Motor size 84 Blade material PA plastic UL94 V0 Fan hou...

Page 6: ...ades of the impeller could be damaged Carefully set down the fan on a soft surface Make sure the blades are not subjected to load Following installation make sure the impeller moves easily and that the blades of the impeller are not deformed or bent and do not catch at any point NOTE Damage to the device from vibration Bearing damage shorter service life The fan must not be subjected to force or e...

Page 7: ... cables including the customer interface are subject to the specifications for internal wiring Ensure conformity with applicable standards and check the degree of protection in the final product after installing the ebm papst device Connect the cables to the mating connectors 4 3 2 Cable routing Water must be prevented from reaching the cable exit along the cable Fans installed lying flat Fig 1 Fa...

Page 8: ...age range 3 DIAG Diagnostic output Open collector Isource max 20 mA Fan OK low fan error high 4 INVLIN not used 5 0 10 V PWM Control input Ri 47 kΩ 0 10 V typ 1 V n 0 1 5 V n min 10 V n max PWM amplitude 10 V 1 50 kHz typ 5 n 0 15 n min 100 n max Item no 53944 5 9970 ENU Change 265422 Approved 2022 08 19 Page 8 11 ebm papst Mulfingen GmbH Co KG Bachmühle 2 D 74673 Mulfingen Phone 49 0 7938 81 0 Fa...

Page 9: ... not switch the motor e g in cyclic operation on and off via power supply Disconnect the device from the power supply 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm papst for repair or replacement WARNING Live terminals and connections even with device switched off Electric shock Wait five minutes after disconnecting the vol...

Page 10: ...vironmental protection and resource preservation are top priority corporate goals ebm papst operates an environmental management system which is certified in accordance with ISO 14001 and rigorously implemented around the world on the basis of German standards Right from the development stage ecological design technical safety and health protection are fixed criteria The following section contains...

Page 11: ...mploying the proper procedures for electronic scrap Please contact ebm papst for any other questions on disposal Item no 53944 5 9970 ENU Change 265422 Approved 2022 08 19 Page 11 11 ebm papst Mulfingen GmbH Co KG Bachmühle 2 D 74673 Mulfingen Phone 49 0 7938 81 0 Fax 49 0 7938 81 110 info1 de ebmpapst com www ebmpapst com ...

Reviews: