background image

Operating instructions

S4D500-BD03-02

Translation of the original operating instructions

3.2 Nominal data

Motor

M4D110-GF

Phase

3~

3~

3~

3~

Nominal voltage in VAC

400

400

400

400

Connection

Δ

Y

Δ

Y

Frequency in Hz

50

50

60

60

Type of data definition

ml

ml

ml

ml

Valid for approval /
standard

CE

CE

CE

CE

Speed in min

-1

1325

1035

1470

990

Power input in W

820

550

1110

590

Current draw in A

1.59

0.95

1.93

1.1

Max. back pressure in Pa

160

100

135

60

Max. ambient
temperature in °C

80

80

50

50

Phase

3~

3~

Nominal voltage in VAC

480

480

Connection

Δ

Y

Frequency in Hz

60

60

Type of data definition

ml

ml

Valid for approval /
standard

CE

CE

Speed in min

-1

1570

1170

Power input in W

1220

770

Current draw in A

1.86

1.13

Max. back pressure in Pa

150

84

Max. ambient
temperature in °C

50

50

ml = max. load · me = max. efficiency · fa = running at free air

cs = customer specs · cu = customer unit

Subject to alterations

3.3 Data acc. to ErP Directive

Installation category

A

Efficiency category

Static

Variable speed drive integrated

No

Specific ratio

*

1,00

*

Specific ratio = 1 + p

fs

/ 100 000 Pa

Actual

Request
2013

Request
2015

Overall efficiency η

es

31,3

29

33

Efficiency grade N

38,3

36

40

Power input P

e

in kW

0,77

Air flow q

v

in m³/h

6045

Pressure increase total p

sf

in Pa

144

Speed n in min

-1

1335

Data established at point of optimum efficiency

3.4 Technical description

Mass

17 kg

Size

500 mm

Surface of rotor

Cast in aluminium

Material of terminal box

ABS Plastic, black

Material of blades

Aluminium sheet insert, sprayed with PP
plastic

Material of guard grille

Steel, phosphated and coated in black
plastic

Number of blades

5

Blade angle

Direction of air flow

"A"

Direction of rotation

Clockwise, seen on rotor

Type of protection

IP 54

Insulation class

"F"

Humidity class

F3-1

Mounting position

Shaft horizontal or rotor on bottom; rotor
on top on request

Condensate discharge
holes

Rotor-side

Operation mode

S1

Motor bearing

Ball bearing

Leakage current

<= 3.5 mA

Electrical leads

Via terminal box

Motor protection

Thermal overload protector (TOP)
brought out

Cable exit

Axial

Protection class

I (if protective earth is connected by
customer)

Product conforming
to standard

EN 61800-5-1; CE

Approval

VDE

For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.

3.5 Mounting data

;

Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).

Strength class for
mounting screws

8.8

You can obtain additional mounting data from the product drawing if
necessary.

3.6 Transport and storage conditions

;

Use the device in accordance with its protection type.

Max. permissible
ambient motor temp.
(transp./ storage)

+ 80 °C

Min. permissible
ambient motor temp.
(transp./storage)

- 40 °C

Item no.: 10739-5-9970 · Revision: 68161 · Print-out: 2012-04-13 · Y. Uhlmann (VM-TDO) · Page 5 / 10

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for S4D500-BD03-02

Page 1: ...t personnel are permitted to transport unpack assemble operate or maintain the device or to use it in any other manner 1 3 Basic safety rules 1 1 3 Basic safety rules Any safety hazards stemming from the device must be re evaluated once it is installed in the end device Observe the following when working on the unit Do not make any modifications additions or conversions to the device without the a...

Page 2: ...s of clothing and jewellery could become entangled and pulled into the device You could be injured Do not wear any loose clothing or jewellery while working on rotating parts Protect long hair by wearing a cap 1 7 Emission WARNING Depending on the installation and operating conditions a sound pressure level greater than 70 dB A may arise Danger of noise induced hearing loss Take appropriate techni...

Page 3: ...ance e g caused by dirt deposits or icing Operation in medical equipment with a life sustaining or lifesaving function Operation with external vibrations Moving solids content in flow medium Painting the device Connections e g screws coming loose during operation Opening the terminal box during operation Moving air that contains abrasive particles Moving highly corrosive air e g salt spray mist Ex...

Page 4: ...ction of air flow A 2 Tightening torque 0 8 0 3 Nm 3 Illustration without terminal box cover 4 Cable diameter min 6 mm max 12 mm tightening torque 2 0 15 Nm Item no 10739 5 9970 Revision 68161 Print out 2012 04 13 Y Uhlmann VM TDO Page 4 10 ebm papst Mulfingen GmbH Co KG Bachmühle 2 D 74673 Mulfingen Phone 49 7938 81 0 Fax 49 7938 81 110 info1 de ebmpapst com www ebmpapst com ...

Page 5: ...aterial of terminal box ABS Plastic black Material of blades Aluminium sheet insert sprayed with PP plastic Material of guard grille Steel phosphated and coated in black plastic Number of blades 5 Blade angle 0 Direction of air flow A Direction of rotation Clockwise seen on rotor Type of protection IP 54 Insulation class F Humidity class F3 1 Mounting position Shaft horizontal or rotor on bottom r...

Page 6: ...side and can damage the device Make sure that the cable end is connected in a dry environment Connect the device only to circuits that can be switched off using an all pole disconnecting switch 4 2 1 Prerequisites Check whether the data on the type plate agree with the connection data Before connecting the device ensure that the supply voltage matches the operating voltage of the device Only use c...

Page 7: ...installed lying flat cable routed as a water trap Fans installed in upright position When routing the cable ensure that the screwed cable glands are arranged at the bottom The cables must always be routed downwards Ill 3 Cable routing for fans installed upright 4 3 4 Motor protection CAUTION Electrical voltage The device is a built in component and features no electrically isolating switch Connect...

Page 8: ... Y Star connection L1 U1 black L2 V1 blue L3 W1 brown W2 yellow U2 green V2 white TOP 2 x grey PE green yellow Item no 10739 5 9970 Revision 68161 Print out 2012 04 13 Y Uhlmann VM TDO Page 8 10 ebm papst Mulfingen GmbH Co KG Bachmühle 2 D 74673 Mulfingen Phone 49 7938 81 0 Fax 49 7938 81 110 info1 de ebmpapst com www ebmpapst com ...

Page 9: ...nges or repairs may be carried out by ebm papst only The terminal box does not have to be opened for maintenance Do not perform any repairs on your device Return the device to ebm papst for repair or replacement WARNING Terminals and connections have voltage even with a unit that is shut off Electric shock Wait five minutes after disconnecting the voltage at all poles before opening the device CAU...

Page 10: ...on At least every 6 months Replacement of the device Mounting the connection lines Visual inspection At least every 6 months Fasten Mounting of protective earth connection Visual inspection At least every 6 months Fasten Check the insulation of the wires for damage Visual inspection At least every 6 months Replace wires Tightness of screwed cable gland Visual inspection At least every 6 months Ret...

Reviews: