background image

Operating instructions

G1G126-AB13-13

Translation of the original operating instructions

You can control the blower either via the 0-10 VDC input or the
PWM input. Attention: The inputs cannot be used simultaneously.

3.2 Nominal data

Motor

M1G055-AI

Nominal voltage / VDC

24

Nominal voltage
range / VDC

20 .. 28

Method of obtaining
data

fa

Speed (rpm) / min

-1

4100

Power consumption / W

44

Min. ambient
temperature / °C

-25

Max. ambient
temperature / °C

70

Min. temp. of flow
medium / °C

-25

Max. temp. of flow
medium / °C

80

ml = Max. load · me = Max. efficiency · fa = Free air

cs = Customer specification · ce = Customer equipment

Subject to change

3.3 Technical description

Weight

1.15 kg

Size

126 mm

Motor size

55

Rotor surface

Thick-film passivated

Impeller material

PA plastic

Housing material

Die-cast aluminum

Direction of rotation

Clockwise, viewed toward rotor

Degree of protection

IP22

Insulation class

"B"

Moisture (F) /
Environmental (H)
protection class

H0 - dry environment

Installation position

Any

Condensation
drainage holes

None

Cooling hole/opening

On rotor side

Mode

S1

Premixing

Not suitable for premixing.

Motor bearing

Ball bearing

Technical features

- Tach output
- Motor current limitation
- PWM control input

Electrical hookup

Plug

Motor protection

Reverse polarity and locked-rotor
protection

Comment

Complete unit must be tested for required
approvals.

With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
cycles. If you have special questions, consult ebm-papst for
support.

;

Use the device in accordance with its degree of protection.

Information on surface quality

The surfaces of the products conform to the generally applicable industrial
standard. The surface quality may change during the production period.
This has no effect on strength, dimensional stability and dimensional
accuracy.
The color pigments in the paints used perceptibly react to UV light over
the course of time. This does not however in any way affect the
technical properties of the products. The product is to be protected against
UV radiation to prevent the formation of patches and fading. Changes in
color are not a reason for complaint and are not covered by the warranty.

3.4 Mounting data

;

Secure the screws against unintentional loosening (e.g. use self-
locking screws).

For screw clearance, see Chapter 3.1 Product drawing

Strength class of
screws

8.8

Any further mounting data required can be taken from the product
drawing or Section Chapter 4.1 Mechanical connection.

3.5 Transport and storage conditions

Max. permitted
ambient temp. for
motor (transport/
storage)

+80 °C

Min. permitted
ambient temp. for
motor (transport/
storage)

-40 °C

Item no. 50402-5-9970 · ENU · Change 202174 · Approved 2018-12-27 · Page 5 / 9

ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · [email protected] · www.ebmpapst.com

Summary of Contents for G1G126-AB13-13

Page 1: ...lified trained and authorized technical staff Only authorized specialists are permitted to install the device to carry out a test run and to perform work on the electrical installation 1 3 Basic safety rules 1 1 3 Basic safety rules The safety hazards associated with the device must be assessed again following installation in the final product The locally applicable industrial safety regulations a...

Page 2: ...s Escaping gas can also cause explosions Never open the blower WARNING Rotating device Long hair and dangling items of clothing jewelry and the like can become entangled and be pulled into the device Injuries can result Do not wear any loose fitting or dangling clothing or jewelry while working on rotating parts Protect long hair with a cap WARNING Ejected parts Missing protective devices may allo...

Page 3: ...ant operation operation with severe vibration This also includes vibration transmitted to the fan from the customer installation Conveying a medium that contains abrasive particles Conveying a highly corrosive medium Conveying a medium with high dust content e g suctioning off sawdust Operating the gas blower in an environment that contains flammable gases or dust or combustible solids or fluids C...

Page 4: ...ing side parts sealed with NBR edge cord pentane resistant 2 Edge connection 2 1 2 2 PWM input 2 3 free 2 4 Speed monitoring 2 5 3 Pressure tap sealed drilled open if required Item no 50402 5 9970 ENU Change 202174 Approved 2018 12 27 Page 4 9 ebm papst Mulfingen GmbH Co KG Bachmühle 2 D 74673 Mulfingen Phone 49 0 7938 81 0 Fax 49 0 7938 81 110 info1 de ebmpapst com www ebmpapst com ...

Page 5: ...regard to cyclic speed loads note that the rotating parts of the device are designed for a maximum of one million load cycles If you have special questions consult ebm papst for support Use the device in accordance with its degree of protection Information on surface quality The surfaces of the products conform to the generally applicable industrial standard The surface quality may change during t...

Page 6: ...age to the device If the device slips during installation serious damage can result Ensure that the device is securely positioned at its place of installation until all fastening screws have been tightened The fan must not be strained on fastening 4 2 Electrical connection CAUTION Voltage The device is a built in component and has no disconnecting switch Only connect the device to circuits that ca...

Page 7: ...ating instructions 4 4 Connection diagram Drawing preliminary Item no 50402 5 9970 ENU Change 202174 Approved 2018 12 27 Page 7 9 ebm papst Mulfingen GmbH Co KG Bachmühle 2 D 74673 Mulfingen Phone 49 0 7938 81 0 Fax 49 0 7938 81 110 info1 de ebmpapst com www ebmpapst com ...

Page 8: ...not switch the motor e g in cyclic operation on and off via power supply Switching off the device for maintenance Switch off the device via the control input Do not switch the motor e g in cyclic operation on and off via power supply Disconnect the device from the power supply 5 MAINTENANCE MALFUNCTIONS POSSIBLE CAUSES AND REMEDIES Do not perform any repairs on your device Send the device to ebm p...

Page 9: ...ve the applicable country specific legal regulations with regard to the disposal of products or waste occurring in the various phases of the life cycle The corresponding disposal standards are also to be heeded 5 3 2 Disassembly Disassembly of the product must be performed or supervised by qualified personnel with the appropriate technical knowledge The product is to be disassembled into suitable ...