ZUM
GB
11
www.eberg.eu
WARNING:
1.
Before removing the plug from the socket and turning off the appliance, allow it to cool down for
30-60 seconds to protect internal parts.
2.
Remote control Install lithium battery, battery model No. CR2025
1.
Before inserting the plug into an electrical outlet, make sure that the electrical supply in your area
matches that on the rating label of the unit.
2.
When plugged in, turn on the Main power switch at the back of the unit.
3.
When in standby mode, only press on the control panel. It will respond to your touch, and the LED
display will show the room temperature. Press to access the rest of the control panel:
(a) Low Power: 1200W (Press to switch it, one light on)
(b) High Power: 2000W (Press to switch it, two lights on together )
(c) TIMER: Press this button repeatedly to set a period after which the heater will turn itself off (From 0
hour - 8 hours)
(d) + , - : adjust room temperature. Temperature setting from 10-49°C. Press “ ” to increase the
desired temperature and “ “ to decrease the desired temperature. When the room temperature is 4°C
lower than the settled temperature of unit, it’s high power working, 2°C lower, it’s low power working, if
room temperature reach the setting temperature, the heating will stop. Fan is permanently on till room
temperature is 2°C lower than the setting temperature (the unit automatically returns to lower power
heating), if room temperature is 4 °C lower than the setting temperature (higher power heating), it’s
automatically turned on.
(e) Swing: Press to activate swing. Press it again to cancel.
(f) Press
to turn off the heater, the unit will keep working for 30-60 seconds to cool down with air, then
it will turn off. This functionality allows to extend the lifespan of the appliance.
4. DEVICE INSTALLATION
5. OVERHEAT PROTECTION
This heater is protected with an overheat protection that switches off the appliance automatically in case
of overheat, e.g. due to the total or partial obstruction of the grids. In this case, unplug the appliance,
wait about 30 minutes for it to cool and remove the object which is obstructing the grids. Then switch it
back on as described above. The appliance should operate normally. Should the problem persist, please
contact the nearest customer service.
NOTE:
To assist in maintaining the internal components, after pressing the OFF button the fan will
continue to blow room air for a period of 30-60 seconds before shutting down to standby