4. TECHNICAL PARAMETERS AND DIMENSIONS
5. INSTALLATION, CONNECTION AND COMMISSIONING
Warning! Before starting work, disconnect the power supply (all poles) and make sure that
unauthorized restarting will not be possible. Installation and electrical connections must be made
by authorized electricians, in accordance with the instructions and applicable regulations, PN and EN
standards, health and safety regulations as well as Technical Conditions. During work, use certified
protective gloves and insulated tools.
The following conditions and instructions in chapter 3 must be respected.
5.1. ASSEMBLY
•
The fan should be mounted at a height not lower than 2.3 m from the floor level or choose a different
place for the installation of the fan, taking into account the safety zones in the bathroom in relation
to the IP class of the device, in accordance with the current regulations.
•
The fan must not be installed in an explosion hazard zone or in a place where it is exposed to water
splashes or high temperature.
•
Take care that no condensate (water) flows to the device.
•
It is not allowed to install the fan in a room with solid or liquid fuel fireplaces or with gas devices
taking the air for combustion from the room and with gravity exhaust gas discharge.
•
Never connect the fan to chimney and flue gas pipes!
•
Only certified materials and assembly accessories should be used, which must be supplied on your
own.
•
Do not remove or change the information signs attached to the device.
5.1.1. INSTALLATION
1. The fan should be mounted in the previously prepared hole at the end of the ventilation duct or the
inlet to the chimney. The area around the opening must be flat and stable. Make sure that there are no
installations at the assembly site.
2. Remove the front panel of the fan and insert the device into the hole to mark the mounting points and
the cable passage. Then, drill the mounting holes.
3. Pass the power cable through the cable entry and, making sure that there are no foreign objects remain
inside the duct, fix the fan casing in a way that allows for later disassembly.
4. Install the front panel, turning it.
Model
V/Hz
P
n
[W]
V
max
[m
3
/h]
A
[mm]
B
[mm]
ØC
[mm]
D
[mm]
E
[mm]
ENSO 100
HYGRO
220-240/50
8
75
160
140
97
100
38