ENGLISH
INTERNAL COMPONENT
QS1
Supply line insulating switch with door locking handle which may be padlocked.
TC1
Safety transformer for the auxiliary circuits.
KM1, KM2,
KM3
Contactors for motor power supply.
XLL1
Motor reactance (present only in models FFP AVS)
KL1
Terminal and relay board connected to the control panel with quick-fit connectors, to control the correct voltage
to the motor and the relief of the current board absorbed.
In the board there are two micro switches (SW1) that are used to control the silencing of the FFSA buzzer (if
present):
- with
SW1-1 → ON
e
SW1-2 → OFF
:
silencing of the buzzer by the panel (SB4 button).
SW1 FFP
SW1 FFSA
- with
SW1-1 → OFF
e
SW1-2 → ON
:
silencing of the buzzer by remote controle (FFSA).
SW1 FFP
SW1 FFSA
KL2
2x16 LCD display board to monitor all system operating conditions, with 4 keys for programming, a key for test
LEDs and one for the switch off of the buzzer
In the back of the board there are two micro switches (SW1), to select:
- with
SW1-1 → ON
, the
TEST WEEK
.
- with
SW1-2 → ON
, the
STOP DELAYED
(REF. UNI 10779).
FUSES
FU1
Fuse protection against short circuits of electric pump power line.
PANEL MOD.
POWER KW
FUSE TYPE
SIZE
FFP 4 T
1.5
10.3x38
4 A aM
FFP 4 T
2.2
10.3x38
6 A aM
FFP 4 T
3
10.3x38
10 A aM
FFP 4 T
4
10.3x38
12 A aM
FFP 7,5 T
5.5
10.3x38
16 A aM
FFP 7,5 T
7.5
10.3x38
20 A aM
FFP 11 TSD
11
14x51
25 A aM
FFP 15 TSD
15
14x51
40 A aM
FFP 18,5 TSD
18.5
14x51
50 A aM
FFP 25 TSD
22 - 25
NH 00
63 A aM
FFP 37 TSD
30
NH 00
80 A aM
FFP 37 TSD
37
NH 00
100 A aM
FFP 55 TSD
45
NH 1
125 A aM
FFP 55 TSD
55
NH 1
160 A aM
FFP 75 TSD
75
NH 1
200 A aM
FFP 11 AVS
11
14x51
25 A aM
FFP 18,5 AVS
15
14x51
40 A aM
FFP 18,5 AVS
18.5
14x51
50 A aM
FFP 25 AVS
22 - 25
NH 00
63 A aM
FFP 37 AVS
30
NH 00
80 A aM
FFP 37 AVS
37
NH 00
100 A aM
FFP 55 AVS
45
NH 1
125 A aM
FFP 55 AVS
55
NH 1
160 A aM
FFP 75 AVS
75
NH 1
200 A aM
The intervention, removes the power from the motor, activate the DL3 signaling, appears in the KL2 display
board and activate the acoustic remote panel. Remove power before performing maintenance.
40
2
1
ON
SWITCH 1
TEST WEEK
SWITCH2
MOD.10779
ON
OFF
OFF
ON