EBARA COMPACT Operating And Maintenance Manual Download Page 4

4

EN

OPERATING AND MAINTENANCE MANUAL PART 2

THE USER SHOULD KEEP THIS DOCUMENT

1. INTRODUCTION

This instruction manual is split into two booklets: PART 1, con-

taining general information regarding our whole product range; 

and PART 2, containing information specific to the motor-driven 

pump you have purchased. The two publications are comple-

mentary to each other, so make sure you have both.

Comply with the instructions contained in them to get the most 

out of your motor-driven pump and assure its proper operation. 

If you need further information, get in touch with your nearest 

authorized dealer.

If information in the two parts contradict each other, take PART 

2 containing the product’s specific information as valid.

NO PART OF THESE ILLUSTRATIONS AND/OR TEXT MAY BE RE-

PRODUCED FOR ANY REASON. 

The following symbols have been used in the compilation of this 

instruction booklet:

WARNING

Risk of damaging the pump or system

Risk of causing injury or damaging property

Electrical hazard

2. CONTENTS

1.  INTRODUCTION  

page 4

2.  CONTENTS  

page 4

3.  MOTOR-DRIVEN PUMP DATA AND DESCRIPTION 

page 4

4.  SPECIFICATIONS 

page 4

5.  PREPARING FOR USE 

page 5

6.  STARTING 

page 5

7.  DIAGRAMS AND DRAWINGS 

page 36

3. MOTOR-DRIVEN PUMP DATA AND DESCRIPTION

3.1. MOTOR-DRIVEN PUMP DATA

Description

MULTISTAGE MOTOR-DRIVEN PUMPS

Model:

COMPACT, MATRIX

Horizontal Shaft

CVM, MULTIGO, HVM, 

MULTIGO IN-LINE

Vertical Shaft

3.2. OPERATING CONDITIONS FOR WHICH PUMPS ARE DE-

SIGNED

These motor-driven pumps (MULTIGO - MULTIGO IN-LINE partly 

built in stainless steel and all-stainless steel MATRIX) assure 

long life and consistent performance if used according to the 

instructions given in chap. 4.

COMPACT / CVM /  MATRIX / HVM
They can be used to increase pressure in general, for domestic 

water boosting (given their silent running, they can even be in-

stalled inside the home), small-scale garden watering, vehicle 

washing and handling of clean water.
Being built in AISI 304 stainless steel, the MATRIX pumps can 

be used even for moderately aggressive water-based solutions. 

For special applications or any applications not contemplated in 

table 4, contact our sales network.

MULTIGO / MULTIGO IN-LINE
Pressure boosting in domestic, community, hospital water sup-

ply systems etc., wherever silent running is called for. Handling 

of liquids reliably and quietly in places subject to flooding and 

wherever systems are subjected to water jets.

3.3. OPERATING CONDITIONS FOR WHICH PUMPS ARE NOT 

DESIGNED

Pumps cannot be used to handle dirty water, water containing 

acids or bases and corrosive liquids in general, water with tem-

peratures higher than those mentioned in chap. 4, saltwater, 

flammable liquids and hazardous liquids in general. It is not suit

-

able for use in swimming pools while people are in the water.

The motor-driven pumps must never be made to work without 

liquid.

4. SPECIFICATIONS

4.1. PUMP SPECIFICATIONS

U/M Matrix 3 Matrix 5 Matrix 10 Matrix 18

Max. temperature of 

liquid pumped 

°C

-15÷110

Max. working 

pressure

MPa

1

Delivery diameter

*

G1

G1

G1

1

4

G1

1

2

Suction diameter

G1

G1

1

4

G1

1

2

G2

U/M

HVM 3

HVM 5

HVM 10

Temperature of liquid 

pumped 

°C

-10÷90

Max. working 

pressure 

MPa

1

Delivery diameter

*

G 1

G 1

1

4

G 1

1

2

Suction diameter

U/M

COMPACT

CVM

MULTIGO - 

MULTIGO IN-LINE

Max. temperature of 

liquid pumped 

°C

40

Max. working 

pressure

MPa

1.1

Delivery diameter

*

G 1

G 1

1

4

Suction diameter

G1 (COMPACT A)

G 1

1

4

 (COMPACT B)

* = threading according to ISO 228

4.2. MOTOR SPECIFICATIONS

COMPACT - CVM 

- MATRIX - HVM

MULTIGO - 

MULTIGO IN-LINE

TYPE

TEFC

Cooled by fluid 

pumped.

Dry-submersible

Insulation class

F

Type of duty

Continuous S1

Overload protection

THERMAL CUTOUT

(single-phase only)

Ratings

See Motor-driven pump’s nameplate

4.3. INFORMATION ON AIRBORNE NOISE

The sound pressure level is below 70 dB* for COMPACT – CVM 

– MULTIGO – MULTIGO IN-LINE pumps.

Summary of Contents for COMPACT

Page 1: ...LINE K ytt ja huolto ohjeosa 2 K NN S ALKUPER ISEST OHJEET 16 ELEKTRISCHE OPPERVLAKTEPOMP COMPACT CVM MATRIX HVM MULTIGO MULTIGO IN LINE Instructiehandleiding voor gebruik en onderhoud VERTALINGVANDE...

Page 2: ...one di giardini lavaggio di veicoli e movimentazione di acqua pulita Le pompe MATRIX essendo costruite in acciaio inossidabile AISI 304 possono essere impiegate anche per soluzioni ac quose moderatame...

Page 3: ...mpa sopra al bocchettone di aspirazione cap 7 FIG 1 b con l ausilio di un imbuto con prolunga flessibile riempire d acqua la pompa fino alla tracimazione c riavvitare il tappo esagonale fino a bloccar...

Page 4: ...even be in stalled inside the home small scale garden watering vehicle washing and handling of clean water Being built in AISI 304 stainless steel the MATRIX pumps can be used even for moderately agg...

Page 5: ...l cap 1 located on the top of the pump casing above the suction port chap 7 FIG 1 b with the aid of a funnel fill the pump with water to overflowing c screw the hexagonal cap back on until it is locke...

Page 6: ...es l arrosage des jardins le lavage des v hicules et l acheminement de l eau propre Les pompes MATRIX tant fabriqu es en acier inoxydable AISI 304 peuvent galement tre utilis es pour des solutions aqu...

Page 7: ...ouchon hexagonal 1 qui se trouve en haut du corps de la pompe sur la bouche d aspiration chap 7 FIG 1 b Remplir la pompe d eau jusqu ce qu elle d borde avec un entonnoir c revisser le bouchon hexagona...

Page 8: ...enbew sserungsanlagen Fahrzeugwaschanlagen und zum Pumpen von sauberem Wasser eingesetzt werden Da die Pumpen MATRIX aus rostfreiem Stahl AISI 304 herge stellt sind k nnen sie auch f r m ig aggressive...

Page 9: ...am Pum penk rper ber dem Ansaugstutzen ab Kap 7 Abb 1 b f llen Sie mit einem Trichter Wasser bis zum berlaufen in die Pumpe ein c ziehen Sie den Sechskantstopfen wieder fest um das Ein dringen von Luf...

Page 10: ...de agua limpia Las bombas MATRIX est n construidas en acero inoxidable AISI 304 y por tanto pueden ser empleadas incluso para solu ciones acuosas moderadamente agresivas Para aplicaciones especiales o...

Page 11: ...te superior del cuerpo de la bomba sobre la abertura de aspiraci n cap 7 FIG 1 b con la ayuda de un embudo llenar de agua la bomba hasta el desbordamiento c apretar el tap n hexagonal hasta bloquearlo...

Page 12: ...ATRIX kan anv ndas ven f r vattenl sningar som r m ttligt aggressiva eftersom de tillverkats av rostfritt st l AISI 304 F r specifika till mpningar som inte finns i tabellen 4 kontakta v ra terf rs lj...

Page 13: ...7 Fig 1 b fyll p vatten i pumpen med hj lp av en tratt upp till m rkt niv c skruva tillbaka den sexkantiga tappen helt och h llet f r att f rhindra att luft tr nger in d s tt ig ng pumpen p maximalt...

Page 14: ...i en bolig mindre vandingsopgaver i haver vask af k ret jer og befordring af rent vand MATRIX pumperne der er udf rt i rustfrit st l AISI 304 kan ogs anvendes til moderat aggressive vandopl sninger T...

Page 15: ...nbragt p pumpekor pussets overside over udsugningsmundingen kap 7 FIG 1 b f yld ved hj lp af en tragt pumpen helt op med vand c Skru det sekskantede d ksel p og stram til s det blo keres for at hindre...

Page 16: ...pin ter ksest valmistettuja MATRIX pumppuja voidaan k ytt my s koh talaisen sy vytt vien vesiliuosten pumppaamiseen Ota yhteys myyntiverkostoomme jos haluat k ytt pumppua johonkin erityiseen tai taulu...

Page 17: ...pes n yl osassa imuaukon yl puolella ole va 6 kulmainen tulppa 1 kohta 7 KUVA 1 b T yt pumppu t ytt laitteen avulla vedell piripintaan c Ruuvaa 6 kulmainen tulppa takaisin paikalleen kunnes se sulkeu...

Page 18: ...stalleerd worden kleinschalige irrigatie van tuinen het wassen van voertuigen en verplaatsing van schoon water Aangezien de MATRIX pompen in roestvrij staal AISI 304 vervaardigd zijn kunnen ze ook wor...

Page 19: ...COMPACT a De zeskantige stop 1 losdraaien die zich bovenop het pomphuis boven de zuigklep hfdst 7 FIG 1 bevindt b met behulp van een trechter de pomp met water vullen totdat deze overloopt c de zeska...

Page 20: ...o silenciosas podem ser instaladas mesmo no interior da habita o pequena ir riga o de jardins lavagem de ve culos e movimenta o de gua limpa As bombas Matrix pois que s o constru das em a o inoxid ve...

Page 21: ...RFEITAMENTE FECHADA PARA ELECTROBOMBA COMPACT CVM MATRIX HVM COMPACT a Desenroscar a tampa hexagonal 1 colocada no topo do corpo da bomba sobre a boqueladura de aspira o cap 7 FIG 1 b com aux lio de u...

Page 22: ...LTIGO MULTIGO IN LINE 3 3 4 4 4 1 Matrix 3 Matrix 5 Matrix 10 Matrix 18 C 15 110 MPa 1 G1 G1 G11 4 G11 2 G1 G11 4 G11 2 G2 HVM 3 HVM 5 HVM 10 C 10 90 MPa 1 G 1 G 11 4 G 11 2 COMPACT CVM MULTIGO MULTIG...

Page 23: ...80 70 70 70 70 2 2 80 70 70 70 70 2 2M 90 70 70 3 90 70 73 70 73 4 90 71 74 74 1 2 5 dB 5 5 1 MULTIGO MULTIGO IN LINE MULTIGO MULTIGO IN LINE 7 2 1 a G 1 1 4 b c 5 2 COMPACT CVM MATRIX HVM 1 6 6 1 CO...

Page 24: ...vody erpadla MATRIX d ky tomu e jsou vyroben z oceli AISI 304 mohou b t pou it i pro m rn agresivn vodn roztoky Pro zvl tn aplikace nebo pro aplikace kter nejsou uveden v tabulce 4 kontaktujte na i pr...

Page 25: ...rdlem kap 7 OBR 1 b pomoc n levky napl te t leso erpadla vodou a do jeho p epln n c op t za roubujte estihrannou z tku a na doraz aby bylo zamezeno pr niku vzduchu d spus te erpadlo v chodu s maxim ln...

Page 26: ...nie istej vody erpadl MATRIX v aka tomu e s vyroben z ocele AISI 304 m u by pou it aj pre mierne agres vne vodn roztoky Pre zvl tne aplik cie alebo pre aplik cie ktor nie s uveden v tabu ke 4 kontaktu...

Page 27: ...i telesa erpadla nad sac m hrdlom kap 7 OBR 1 b pomocou lievika napl te erpadlo vodou a do jeho preplnenia c zaskrutkujte es hrann z tku a na doraz aby sa zabr nilo vstupu vzduchu d spus te chod erpad...

Page 28: ...grod w mycia pojazd w i przepompowywania czystej wody Pompy MATRIX kt re wykonane s ze stali nierdzewnej AISI 304 mog by stosowane r wnie dla roztwor w wodnych umiarkowanie r cych W sprawie zastosowa...

Page 29: ...U ELEKTROPOMP KOMPAKTOWYCH CVM MATRIX HVM COMPACT a Odkr ci nakr tk sze ciok tn 1 znajduj c si wierzcho ku korpusu pompy nad otworem zasysania rozdz 7 RYS 1 b Za pomoc lejka nape ni pomp wod a do prze...

Page 30: ...CT CVM MATRIX HVM MATRIX AISI 304 4 MULTIGO MULTIGO IN LINE 3 3 4 4 4 1 Matrix 3 Matrix 5 Matrix 10 Matrix 18 C 15 110 1 G1 G1 G11 4 G11 2 G1 G11 4 G11 2 G2 HVM 3 HVM 5 HVM 10 C 10 90 1 G 1 G 11 4 G 1...

Page 31: ...70 1 5 80 70 70 70 70 2 2 80 70 70 70 70 2 2M 90 70 70 3 90 70 73 70 73 4 90 71 74 74 1 2 5 5 5 1 MULTIGO MULTIGO IN LINE BH MAH E MULTIGO MULTIGO IN LINE 1 7 2 a G 11 4 b c 5 2 COMPACT CVM MATRIX HV...

Page 32: ...ecede agresif sulu sol syonlar i in de kullan labilirler zel veya 4 tabloda belirtilmeyen uygulamalar i in sat a m za dan n MULTIGO MULTIGO IN LINE lemede sessizli inin gerekli oldu u t m domestik ve...

Page 33: ...ta ma seviyesine kadar su ile doldurunuz c Hava s zmas n nlemek i in alt gen t pay bloke olana kadar s k t r n z d Pompay birka dakika maksimum kapasitede al t r n z CVM a Besleme a z n n kar yan ndak...

Page 34: ...34...

Page 35: ...35...

Page 36: ...UND ZEICHNUNGEN 7 ESQUEMAS Y PLANOS 7 SCHEMAN OCH RITNINGAR 7 DIAGRAMMER OG TEGNINGER 7 KAAVIOT JA KUVAT 7 SCHEMA S EN TEKENINGEN 7 ESQUEMAS E DESENHOS 7 7 SCH MATA A V KRESY 7 SCH MY A V KRESY 7 SCHE...

Page 37: ......

Page 38: ......

Page 39: ......

Page 40: ...el 48 22 3909920 Fax 48 22 3909929 e mail mktgpl ebaraeurope com EBARA Pumps Europe S p A GERMANY Elisabeth Selbert Stra e 2 63110 Rodgau Germany Tel 49 0 6106 66099 0 Fax 49 0 6106 66099 45 e mail mk...