19
EBARA
PUMPS AMERICAS CORPORATION
www.pumpsebara.com
(t) 803.327.5005 (f) 803.327.5097
rev. 01/21
EBARA Submersible Sewage Pumps
Operating, Installation, and Maintenance
DL3FU / DL3MFU / DL3KFU / DL3KMFU / DDL3FU / DV3FU/ DML3FU
INSTRUCTION MANUAL
P.18
PM32U
(Head)
Total head
(H1 + H2) m
Shaft output
(Amperage)
Total head
Rated output
(Rated amperage)
(Capacity)
Solid line : Normal
Broken line : Reversed
Fig. 12 Pump performance of Normal Rotation VS reverse rotation
L1
L2
L3
L2
L1
L3
Motor
Motor
L3
L1
L2
L3
L2
L1
Fig. 13 Change two of Connections for proper rotation and Normal Pump Performance
(2) If the pressure gauge or compound pressure gauge is not installed on the discharge
pipe, if checks of the rotating direction of the pump in the water as described above
cannot be performed, proceed as follows.
Lay the pump on the ground. Turn switch on and off instantaneously
and check visually
the rotation direction through the discharge bore of the pump. The rotating direction of
the pump should be clockwise when viewed from top of motor.
CAUTION:
SINCE THE STARTING TORQUE ON LARGE PUMPS CAN BE POWERFUL,
THE PUMP MUST BE PROPERLY SUPPORTED.
DANGER:
DURING CHECKING THE DIRECTION OF ROTATION, DO NOT TOUCH
ROTATING PARTS OF THE PUMP. KEEP HANDS, FEET, LIMBS, HAIR AND TOOLS AWAY
FROM ROTATING PARTS TO PREVENT SERIOUS ACCIDENTS.
!
!