Tel 800 992 5013 / +1 508 234 6158
|
www.eaw.com
38
Line Array
Application Guide
KF810P Ground Stack with SB818P|F
• Place your SB818P|F on the ground.
• To attach additional SB818P|F, lift on top of SB818P|F beneath and use M8 x 22 bolts w/
flat and lock washers to secure front and rear rigging (See Resolution for ground-stack
limitations).
• To add KF810P, start by placing frame on top of SB818P|F array, and securing front and rear
rigging with M8 x 30 bolts w/flat and lock washers. “Z” hole needs to be orientated towards
the front of intended array.
• Place the first KF810P on top of frame, and secure front rigging with M8 x 22 bolts w/flat and
lock washers (See Resolution for ground-stack limitations).