Eaton xComfort F94 Series Assembly Instructions Manual Download Page 8

8

 
 

Affixing date of CE mark: 2012 
 
Doc.Id.: F9401, F9402, F9404 

        Heinz Ursprunger          Friedrich Schröder 
     Director Product Line          Director Quality 
  & Marketing Management 

    & EHS 

Declaration of Conformity 

We,   EATON Industries (Austria) GmbH 
 

3943 Schrems, Eugenia 1 

 Austria 
 
declare that product (family) 
 

Eaton - MEM switch module, 

F9401, F9402, F9404 

 
(the declaration of conformity applies to all  
listed types within our actual product catalog) 
 
provided that it is installed, maintained and used in the 
application intended for, with respect to the relevant manufacturers 
instructions, i

nstallation standards and “good engineering practices”

 

 
complies with the provisions of Council directive(s): 

 

 

 

 EMC 

Directive 

2004/108/EC 

 

 

Radio and Telecommunications Terminal Equipment 99/05/EC 

 

 

 

based on compliance with European standard(s): 

 

EN301489-3 V1.6.1, EN300220-2 V2.4.1, EN50491-5-1/10, 
EN50491-5-2/10, EN60950-1/06 + A11/09 + A1/10 + A12/11 +A2/13, 
EN62479/10 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
01.12.2014 
 

 

 

Summary of Contents for xComfort F94 Series

Page 1: ...ule CP902xx Clip on plate Typical Application Scope of delivery Mounting Frame Decorative Plastic Metal Plate Style List No List Finish List No Finish Surface Mounting Frame F9400 CP902WH White CP902SS Stainless Steel CP902BM Black Matt CP902HP Highly Polished Copa Flush 2 Module C902 CP902GL Gold Metalic CP902SB Satin Bronze CP902SL Silver Metalic CP902PB Polished Brass CP902BL Blue Metalic CP902...

Page 2: ... 5 1a 3 6 7 1b 4 Click P9400 Surface Mounted on flat surface P9400 Flush Mounted on wall box P9400 Surface Flush mount with clip on cover Screw caps if required 4 x Click Flush mount Premera Frame e g P902 ...

Page 3: ... screwdriver to release module from surface plate Mounting screws Screw caps if fitted Remover screw cap discs if fitted along with mounting screws to release flush plate from wall box and allow access to battery at rear of module Note If Push button modules are either mounted on metal back boxes or used with metal clip on plates then the RF range may be restricted ...

Page 4: ...lashes twice for confirmation 4 Press the configuration pushbutton with a screwdriver for less than 0 5 sec actuator leaves teach in mode Assign a room thermostat to an actuator 1 Press the configuration pushbutton with a screwdriver for less than 0 5 sec actuator enters teach in mode the LED in the actuator is on 2 Turn the control knob to 3 The LED in the actuator flashes twice for confirmation ...

Page 5: ...2 Press the selected remote push button until the LED has flashed 5 times 3 Press the configuration pushbutton with a screwdriver for less than 0 5 sec actuator leaves teach in mode Unlink an assigned room thermostat 1 Press the configuration pushbutton with a screwdriver for less than 0 5 sec actuator enters teach in mode the LED in the actuator is on 2 Turn the control knob on the room thermosta...

Page 6: ...onfiguration pushbutton with a Screwdriver for longer than 2 sec actuator enters the manual mode for 10 sec the LED flashes fast 2 Press the configuration pushbutton with a screwdriver for less than 0 5 sec Shutter moves up 3 Press the configuration pushbutton with a screwdriver for less than 0 5 sec Shutter moves down 4 After 10 sec the actuator leaves automatically the manual mode 4 Reset actuat...

Page 7: ...w sent to the router and from there forwarded to the actuator The LED in the actuator flashes twice for confirmation 5 Finally press the configuration pushbutton with a screwdriver for less than 0 5 sec actuator leaves teach in mode 6 Configure two routers CROU 00 01 in Basic Mode 1 If the range of a single router is not sufficient a second one can be added to extend RF range further 2 Assign a pu...

Page 8: ...s to all listed types within our actual product catalog provided that it is installed maintained and used in the application intended for with respect to the relevant manufacturers instructions installation standards and good engineering practices complies with the provisions of Council directive s EMC Directive 2004 108 EC Radio and Telecommunications Terminal Equipment 99 05 EC based on complian...

Reviews: