background image

Wiring Preparation

Attachment screw

Cover

G

Center body post gasket

G

Cover gasket

Power input
R1:

Ramp adjustment. Turn clockwise 

to increase ramp time.

R3:

Deadband   compensation 
 adjustment. 
Turn clockwise to reduce deadband 
compensation current

R2:

Gain adjustment. Turn clockwise to 
decrease gain.

Body

G

Mounting gasket

Cable grommet

Grommet cinch nut

LED

Command signal input

0V

Electronic module

G

 All seals must be fitted correctly at plug 

installation to provide protection to IP65
(IEC 529)

WARNING

Ensure cable clamp nut is adequately
tightened to secure the cable.

Do not connect or disconnect the
plug while power is on.

Do not mount or dismount the plug
when power is on.

3 x 0,5–1,0 mm

2

(20AWG-18AWG)

O

5 – 10

(0.197–0.394 dia.)

Use single cable
with round outer
jacket such as:
Alpha #1952/3
Belden #8770

Stretch cable
grommet
over outer
jacket

5 (0.2)

Figure 6. Power plug exploded view

Vickers, Incorporated
A TRINOVA Company
5445 Corporate Drive
Troy, MI 48007–0302
Phone: (313) 641–4500
Fax:

(313) 641–4948

630 Rel 5/93