Wiring Preparation
Attachment screw
Cover
G
Center body post gasket
G
Cover gasket
Power input
R1:
Ramp adjustment. Turn clockwise
to increase ramp time.
R3:
Deadband compensation
adjustment.
Turn clockwise to reduce deadband
compensation current
R2:
Gain adjustment. Turn clockwise to
decrease gain.
Body
G
Mounting gasket
Cable grommet
Grommet cinch nut
LED
Command signal input
0V
Electronic module
G
All seals must be fitted correctly at plug
installation to provide protection to IP65
(IEC 529)
WARNING
Ensure cable clamp nut is adequately
tightened to secure the cable.
Do not connect or disconnect the
plug while power is on.
Do not mount or dismount the plug
when power is on.
3 x 0,5–1,0 mm
2
(20AWG-18AWG)
O
5 – 10
(0.197–0.394 dia.)
Use single cable
with round outer
jacket such as:
Alpha #1952/3
Belden #8770
Stretch cable
grommet
over outer
jacket
5 (0.2)
Figure 6. Power plug exploded view
Vickers, Incorporated
A TRINOVA Company
5445 Corporate Drive
Troy, MI 48007–0302
Phone: (313) 641–4500
Fax:
(313) 641–4948
630 Rel 5/93
Printed in U.S.A.