background image

3

Mounting and Operating Instructions Fire-Resistant Cabinet Type US-S ESF30

 40071860245 (B) February 2020 www.ceag.de

1  Important information

1  Important information

1.1 General

Mounting work must always be performed by qualified 

electricians (also refer to DIN VDE 0105 Part 1, the German 

Accident Prevention Regulations in BGV A3 issued by the 

Association of Commercial and Industrial Workers' Com-

pensation Insurance Carriers [Berufsgenossenschaft] or 

equivalent regulations and guidelines of the country where 

the equipment is installed and operated). Other persons 

are only authorised to perform the work described in these 

instructions when
•   they have received appropriate subject matter and techni-

cal instructions,

•   their tasks and activities have been precisely defined and 

understood,

•   the activities are carried out under the supervision of 

specialists and experts.

Please observe:

•   the accident prevention guidelines and workplace directive,

•   the instructions issued by the technical regulatory agency,

•   DIN4102 to assess fire safety and structural/technical 

aspects,

•   the technical specifications in our catalogue or datasheet,

•   the proper condition of the products.

•   Comply with the general building law and the building 

requirements.

•   Comply with the corresponding standards to evaluate fire 

protection and building aspects

•  Screw connections for the framework may only be made 

using approved, suitable screws/dowels.

•  The suitability of the screws/dowels must be checked for 

the specific framework.

If the cabinet has not yet been bolted to the building struc-

ture, the stability of the equipment is compromised when 

the door is open. 
The doors must be kept closed when the equipment is in 

operation.
Improper installation can compromise the safety functions.
Only approved and appropriate screws/dowels must be 

used as fasteners to the building structure. The suitability 

of screws/dowels must be determined specifically for each 

building.
The enclosures must not be painted or coated otherwise; 

stickers are prohibited. The enclosure body must not be 

damaged (drilling holes, screws). The locking systems must 

not be modified or replaced.
When working with these mounting and installation instruc-

tions, the following instructions highlighted with an attention 

symbol and a keyword must be specifically observed.

1.2 Key to symbols

Important technical safety information in these operating 

instructions is designated by symbols.

 NOTE:

Provides important tips and pointers on procedures, or for 

handling the described equipment or plant components.

 ATTENTION!

Calls attention to hazards that can cause damage to equip-

ment or plant components, or can result in environmental 

damage.

 WARNING!

Calls attention to hazards that can result in bodily injuries or 

cause serious damage to equipment or plant components, 

or can result in serious environmental damage.

 DANGER!

Calls attention to hazards that can cause life threatening 

injuries or serious damage that represents a direct danger 

for people or the environment.

 WARNING!

The figures in these mounting and installation instructions 

are partly for the purpose of illustrating the descriptions.
Any time
•  exact measurements or

•   accurately modified drawings to reflect local conditions 

are required, any drawings specifically prepared for the 

installation must be bindingly observed.

 WARNING!

Only perform work for which you have sufficient trade quali-

fications, and for which you have been briefed on the local 

operating conditions.
Whenever enhancements, modifications, maintenance, or 

work not described in this manual are required, these must 

be performed by specifically trained specialists and service 

personnel (either from CEAG as the manufacturer or sales 

and service companies authorised by CEAG)!

1.3 Information for the mounting and installa-

tion instructions

Please store these mounting and installation instructions in 

a safe place - they are an integral component of the supplied 

mains distribution cabinet. Safe and approved function can 

only be assured if this manual is adhered to.

1.4 Applicable documents

The mounting and installation instructions for the central 

battery systems ZB-S must be observed in addition to the 

mounting and installation instructions.

1.5  Liability, warranty, and transfer of cus-

tody declaration

•   In order to ensure optimum functionality of our products, 

the mounting instructions must be observed without 

exception.

•   CEAG's warranty covers the supplied products.

•   Modifications or changes of the design are only author-

Summary of Contents for US-S ESF30 13-P

Page 1: ...ng Instructions US S ESF30 Mounting and Operating Instructions Fire Resistant Cabinet Type US S ESF30 Target group qualified electricians according to DIN VDE 0105 Part 1 Target group part 2 Electrica...

Page 2: ...3 8 4 4 2 Dimensioned drawings US S ESF30 SOU3 8 4 5 US S ESF30 SOU2 9 4 5 1 Components US S ESF30 SOU2 9 4 5 2 Dimensioned drawings US S ESF30 SOU2 9 4 6 US S ESF30 SOU1 9 4 6 1 Components US S ESF30...

Page 3: ...with these mounting and installation instruc tions the following instructions highlighted with an attention symbol and a keyword must be specifically observed 1 2 Key to symbols Important technical s...

Page 4: ...rn or disposal agreement was concluded dis mantled components must be recycled after having been properly disassembled 2 Safety At the time of its development and production the device was manufacture...

Page 5: ...t only be operated if it is in an exemplary and operationally safe condition The equipment must be checked every time before it is put into operation The operating instructions as set out in the manua...

Page 6: ...tic control of external temperature 4 Web module 5 DLS module 6 Thermostatic control temperature exceeded 7 Control module CU CG S 8 DC module 9 Circuit switch overs SKU CG S 1 2 4 3 5 8 7 6 9 4 1 US...

Page 7: ...of internal temperature 3 Thermostatic control of external temperature 4 Web module 5 DLS module 6 Thermostatic control temperature exceeded 7 Control module CU CG S 8 DC module 9 Circuit switch over...

Page 8: ...3 1 Components US S ESF30 SOU5 4 4 US S ESF30 SOU3 4 4 1 Components US S ESF30 SOU3 230 396 1135 4 3 2 Dimensioned drawings US S ESF30 SOU5 230 396 1135 230 396 1135 396 230 835 4 4 2 Dimensioned draw...

Page 9: ...4 5 1 Components US S ESF30 SOU2 396 230 685 4 5 2 Dimensioned drawings US S ESF30 SOU2 396 230 685 396 230 685 1 Enclosure 2 Circuit modules SOU CG S 2 x 4 A 1 2 4 6 US S ESF30 SOU1 4 6 1 Components...

Page 10: ...sure is not immediately used or installed it needs to be stored in an appropriate location Ensure that spray water cannot form or penetrate do not store outdoors Fire protection enclosures have an int...

Page 11: ...building supervisory or European technical approval or European assessment shall be observed The choice of suitable wall plugs for masonry must be made depending on the type of blocks solid or perfora...

Page 12: ...oors properly close when locking theenclosure 6 9 Special features US S ESF30 28 P and 13 P The door swing can be changed locally on the right side by default Door can be unhinged to reduce weight for...

Page 13: ...uting in the distribution cabinet Pre drill the point where the cable is to be inserted accor ding to the cable diameter Observe internal insulation mounting plates and fan Insert existing cables thro...

Page 14: ...a qua lified electrician 1 Disconnect the fan unit from the supply voltage taking care about VDE 0100 230 V mains connection before beginning to dismantle Determine freedom from tension WARNING 230 V...

Page 15: ...8 Ventilation diagram ATTENTION The black compriband is part of the ventilation system and ensures among other things that only the fresh supply air comes from below at the lower rear side This band m...

Page 16: ...Battery life 2 years Protection IP32 Operating temperature 0 55 C Humidity 93 Before starting up the batterie of the smoke detector has to be inserted and the function has to be guaranteed ATTENTION W...

Page 17: ...Connection plan 11 Connection plan ATTENTION Danger caused by electrical voltage WARNING 230V AC Dangerous Voltage May cause death heavy body injuries and property damage Disconnect all poles of the d...

Page 18: ...securely sealed 9 Setup and installation US S ESF30 SOU5 SOU3 SOU2 SOU1 9 1 Wall mounted installation Only the dowels or anchor screws described in the General construction code approval must be used...

Page 19: ...19 Mounting and Operating Instructions Fire Resistant CabinetType US S ESF30 40071860245 B February 2020 www ceag de Notes Notes...

Page 20: ...s to find the right solution for every application Our stakeholders therefore expect more than just innovative products Companies turn to Eaton because they know that individual support and the succes...

Reviews: