Sonix Ms12 Technical Manual

SONIX MS12 TECHNICAL MANUAL  

TM371 / A  June 2022  www.eaton.com

6 .4  Message recording / loading

The unit will record audio signals from devices such as 

mobile phones, computers etc. providing it will output 

via a standard 3.5mm jack. It is recommended that the 

audio file to be recorded onto the unit is generated in 

mono.

The audio source for the message to be recorded should 

be ready on the playback device. When the message 

slot red indicator changes from fast flashing, (erasing), to 

solid, (start of recording), playback of the source should 

be started. Recordings that over run the maximum 

record time will still be valid up to the maximum time 

allowed:

The message loading process may need to be repeated 

several times at different audio output levels in order to 

achieve the best clarity. The output level and clarity of 

the original recording will significantly affect the unit’s 

recording of the message.

Message slots 1-11 allows up to 60 seconds of recording 

length, while slot 12 can store a message up to 5 

minutes long.

 

ote: 

N

It is recommended the line input is disabled in configuration after 

recording all messages as this will prevent accidental deletion / over-

writing of messages when using the front panel, see SAS manual for 

more details.

Once a message slot has been selected for record (see 

section 6.3.3) the record process begins:

Figure 10 - Record process flow

Once the associated message slot Red indicator goes 

solid the unit is recording. To finish the recording process 

a single press of the front panel button informs the unit 

that no more audio is to be expected.

Each stage of the recording process is indicated on the 

front panel indicators for the selected message slot, see 

section 6.2.2.4 for more details.

Summary of Contents for SONIX Ms12

Page 1: ...SONIXTM Ms12 Message Store Unit SonixTM Ms12 Technical Manual...

Page 2: ...FOR A PARTICULAR PURPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF...

Page 3: ...feedback 2Mx Sonix 2Mx Central controller Amp 350 d Sonix 350 W Power Amplifier with 100 V line output Eol1 Sonix Remote End of Line unit Eol8 Sonix Amplifier to 100 V line interface unit 8 channel S...

Page 4: ...key line outputs 11 5 3 Line In 11 5 4 Message Initiate 12 5 5 Power connections 12 5 6 General fault output connections 12 6 UNIT OPERATION 13 6 1 Data and audio communications 13 6 1 1 PA GA mounted...

Page 5: ...ity 23 8 CUSTOMISATION 23 9 MAINTENANCE 23 List of Figures FIGURE 1 FRONT PANEL LAYOUT 10 FIGURE 2 REAR PANEL LAYOUT 10 FIGURE 3 ISOLATED AUDIO AND KEYLINE OUTPUTS 11 FIGURE 4 MESSAGE INITIATE CONNECT...

Page 6: ...MESSAGE STATUS INDICATOR DESCRIPTION 14 TABLE 10 PLAYBACK MESSAGE GREEN STATUS INDICATOR DESCRIPTION 14 TABLE 11 PLAYBACK MESSAGE RED STATUS INDICATOR DESCRIPTION 14 TABLE 12 FRONT PANEL PLAYBACK GREE...

Page 7: ...7 Sonix Ms12 Technical Manual SONIX MS12 TECHNICAL MANUAL TM371 A June 2022 www eaton com...

Page 8: ...e goods during transit Please ensure that once unpacked checked and installed that all packaging is disposed recycled in a responsible manner 2 3 ESD Electro Static Discharge The Sonix PA GA system is...

Page 9: ...to the needs of system installation The unit allows for duplicated connections to A side and B side systems while allowing synchronised audio to be broadcast over both systems The unit occupies a stan...

Page 10: ...OWERSUPPLY OPERATIONAL 7 6 5 4 3 2 1 I O Bus A I O Bus B A1 A2 SCN K1 K2 A SIDE O P 48V DC I P Fault O P N C Com COM N C COM N C COM N C COM N C COM N C COM N C COM N C COM N C COM N C COM N C COM N C...

Page 11: ...e system for redundancy Bus Name Colour Connected to Data type IO Bus Blue Io Ms12 PBx units Transmit Unit control status data Active system Audio Receives System control and status data Table 3 IO Bu...

Page 12: ...side Figure 5 Power connections Maximum cable section supported are Solid 1 5 mm2 Stranded 0 5 mm2 including sleeved ferrule Stranded 1 5 mm2 including non sleeved ferrule 5 6 General fault output co...

Page 13: ...of either one of a pair of RJ45 cable becoming disconnected the data audio has a redundant path ensuring the Ms12 will continue to operate without any loss of functionality A flashing IO fault is log...

Page 14: ...n be accessed to check message content using the front panel Table 13 Playback message red status indicator description 6 2 2 4 Front panel record These indications are only displayed by the unit whil...

Page 15: ...Local Reset Solid green Allows the user to carry out a fault reset on the unit Table 19 Switch indicator description 6 3 Front panel operation From the front of the Ms12 a selection button on the rig...

Page 16: ...ont panel button allow the selected message to be cycled The selected message will play once before returning to quiescent Playback Message Select no message Timeout Button Pressed Message Select Time...

Page 17: ...s For more detailed information and instructions please see section 6 4 6 3 3 1 Message slot selection To a record a new message the user needs to identify the message slot to use This is achieved usi...

Page 18: ...in order to achieve the best clarity The output level and clarity of the original recording will significantly affect the unit s recording of the message Message slots 1 11 allows up to 60 seconds of...

Page 19: ...while the input is active De activating an input after the message has started will cause it to play to the end before stopping ote N Initiating and holding active a rear panel initiate will cause the...

Page 20: ...nitiation 6 7 Message Playback Once a message has been initiated for playback the unit enters the playback process This process differs depending on whether the unit is connected with CAT6A cables as...

Page 21: ...sage slot can be individually configured to auto elevate to Emergency Speech If a message is elevated to Emergency Speech broadcast its priority is raised above any active Alarms on the PA GA system a...

Page 22: ...ated from each other J9 and J10 on the PCB are two jumper links to connect the shield from each CAT6A connector to either Earth or to the respective 0V rail ote N J9 and J10 should be left connected t...

Page 23: ...ve if the custom special functionality or operation of the Sonix system and or Ms12 is required 9 Maintenance The Sonix Ms12 unit itself does not require any specific maintenance but the following gen...

Page 24: ...aton and SONIX are registered trademarks All other trademarks are property of their respective owners Changes to the products to the information contained in this document and to prices are reserved s...

Reviews: