background image

Eaton

®

 93PM Remote Monitoring Device

Installation and Operation Manual

Summary of Contents for RMD

Page 1: ...Eaton 93PM Remote Monitoring Device Installation and Operation Manual...

Page 2: ...dure d installation Veuillez consulter enti rement ces instructions avant de faire fonctionner l quipement et conserver ce manuel afin de pouvoir vous y reporter ult rieurement Eaton is registered tra...

Page 3: ...1 i Table of Contents INTRODUCTION 1 INSTALLATION 3 Network Card Installation 3 Network Card Configuration 3 RMD Installation 4 OPERATION 6 RMD Components 6 Display Screen Sections 6 Powering the RMD...

Page 4: ...1 Eaton 93PM Remote Monitoring Device 1 Figure 2 RMD Dimensions 1 Figure 3 RMD Wall Mounting Bracket 2 Figure 4 Location of RMD Components 5 Figure 5 Display Screen Sections 7 Figure 6 Communication...

Page 5: ...o 300 feet from the UPS It will display the general state of the UPS and key metrics like battery charge and available runtime when on battery It is not a full remote display and it does not offer any...

Page 6: ...Introduction 2 Eaton 93PM Remote Monitoring Device RMD Installation and Operation Manual P 164000516 Rev 1 Figure 3 RMD Wall Mounting Bracket Locking Latch Bottom Support Rail Charger Connector Access...

Page 7: ...ivate Class C network To set up the PXGMS card 1 Download the powerxpert inf file to provide USB driver support for the Linux USB Ethernet RNDIS Gadget on Windows 7 or XP from the Eaton website at htt...

Page 8: ...at the bracket is being mounted on to secure the bracket to the wall 2 Mount the RMD in the bracket by placing the bottom edge of the RMD into the bracket bottom rail support and then snapping the top...

Page 9: ...ng Device RMD Installation and Operation Manual P 164000516 Rev 1 5 Figure 4 Location of RMD Components 4 3 Display Screen Power Pushbutton Micro USB Audible Alarm Speaker Buzzer Ethernet 10 100 RJ45...

Page 10: ...e display screen sections l Input This icon shows the state of the incoming power It is green if the power is available and good If it turns yellow the voltage or frequency of the electrical power is...

Page 11: ...let the battery charge for 30 minuets To turn the RMD off press and hold the power pushbutton on the front of the RMD for approximately 11 seconds If a white screen is displayed on the RMD after the...

Page 12: ...connection If this indicator is not illuminated it indicates a valid 10 Mb connection as long as the corresponding ACT is blinking green If the Activity LED on the RMD is not blinking green check that...

Page 13: ...l and all status indicators will be illuminated green as shown in Figure 7 Figure 7 Normal Screen On Battery Screen When the UPS is on battery the status indicators will be displayed as shown in Figur...

Page 14: ...ault condition occurs the status indicators and information area will be displayed as shown in Figure 10 and indicates the UPS has an active alarm and requires immediate attention If this occurs check...

Page 15: ...llation and Operation Manual for the UPS Minislot location and wiring access information Visit www eaton com powerquality or contact an Eaton service representative for information on how to obtain co...

Page 16: ...12 Eaton 93PM Remote Monitoring Device RMD Installation and Operation Manual P 164000516 Rev 1 This page intentionally left blank...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...P 164000516 1 P 164000516 1...

Reviews: