Eaton 9390 Uninterruptible Power System

Scalable architecture meets your current and 
future load requirements

The 9390 supports up to 160 kVA to deliver power protection for small branch offices to large corporate 
data centers and communication networks. Up to six equivalent 9390 modules can be paralleled for 
additional capacity or redundancy, without having to utilize a central bypass cabinet. In all paralleling con-
figurations, each UPS module operates independently yet is completely synchronized with the others. 
Parallel UPS modules can provide N+1, N+2, or greater redundancy. 

Powerware Hot Sync 
technology: The 
culmination of power 
reliability

Eaton’s patented Powerware 
Hot Sync technology enables 
multiple UPSs to share the load 
equally, eliminating the transfer 
time when shifting the load 
from one module to the other. 
The load share control algo-
rithms maintain adjustments to 
variations in the output power 
requirements.

When two or more UPSs oper-
ate in parallel for capacity and 
redundancy, Hot Sync addresses 
the two primary concerns of 
load sharing and selective trip-

Powerware Hot Sync wireless paralleling technology for capacity or redundancy

This two-module system shown below can be configured as 160 kVA N+1 redundant (320 kVA capacity 
with 36-inch tie cabinet). The width of this configuration is a compact 164.6 inches.

Tie Cabinet

160 kVA UPS Modules

Battery

Battery

ping. To address these concerns 
for reliability – the degree of 
autonomy and the complexity 
of implementation – Hot Sync 
combines digital signal process-
ing and an advanced control 
algorithm to provide automatic 
load sharing and selective trip-
ping in a parallel system, as well 
as complete autonomy of the 
modules and a skillfully simple 
implementation. The  9390 
achieves optimum reliability 
and flexibility with the following 
design features:

•  Unlike other paralleling tech-

niques, there is no system-
level single point of failure

•  Hot Sync systems are capable 

of paralleling for both redun-
dancy and capacity

•  By using a peer configura-

tion as opposed to a master-
slave configuration, Hot Sync 
ensures that each module is 
operating independently

•  No added circuitry or com-

ponents are required to be 
switched in to operate in 
parallel

•  With thousands of successful 

systems installed globally, Hot 
Sync is a proven technology

•  The output of multiple UPSs 

remains in phase so that 
static transfer switches con-
nected between the separate 
distribution paths may change 
state seamlessly when nec-
essary

Each parallel unit operates with 
its own battery string – if any 
unit goes offline or is taken 
down for maintenance, the 
remaining units support the 
load fully with their battery 
capabilities. If any battery string 
fails, the remaining strings con-
tinue to support the load – thus 
eliminating a key potential single 
point of system failure.

Summary of Contents for Powerware 9390

Page 1: ...PowerChain Management solutions 20 160 kVA Eaton 9390 UPS...

Page 2: ...2 EATON CORPORATION Product Catalog Eaton 9390 20 160 KVA...

Page 3: ...e power system UPS is a double conversion UPS that resolves all utility power problems and supplies clean continuous uninterruptible power to connected equipment Whether you re selecting a UPS for a b...

Page 4: ...86 88 90 92 94 96 98 94 65 Load Eaton 9390 160 kVA Efficiency Curve Efficiency Operational savings Efficiency comparison Efficiency difference 2 3 4 1 year 5 years 1 year 5 years 1 year 5 years Savin...

Page 5: ...eading Lagging 1 0 75 0 50 0 25 0 0 25 0 50 0 75 1 kVAr kW PF 0 9 100 kW PF 1 PF 0 9 PF 0 8 Without derating 1 0 75 0 50 0 25 Many competitive UPSs cannot operate in this range without significant der...

Page 6: ...is configuration is a compact 164 6 inches Tie Cabinet 160 kVA UPS Modules Battery Battery ping To address these concerns for reliability the degree of autonomy and the complexity of implementation Ho...

Page 7: ...floor space requirements Advanced battery management optimizes battery performance and service life Eaton s ABM technology uses a unique three stage charg ing technique that significantly extends batt...

Page 8: ...itical alarm notification and monthly reports on UPS battery health 7x24 technical support access In addition to the warranty and first year of on site coverage Eaton offers a wide variety of support...

Page 9: ...titive advantage If your company is like most its power system was built over time As the organization s needs changed additional equip ment was likely retrofitted into the system with a circuit break...

Page 10: ...for your needs Medical imaging and equipment protection Having been tested and certified for use in medical imaging system applications by all major suppliers of X ray MRI and CT machines the 9390 me...

Page 11: ...ith a three year warranty other battery configurations are available with a one year warranty Serviceability Front access only design and top bottom cable entry provides installation flexibility and e...

Page 12: ...ith this optional cabinet Eaton offers a complete one stop shop for power protection and distribution solutions that is easy to design install custom ize and manage while deliver ing pay as you grow s...

Page 13: ...13 www eaton com powerquality 1 800 356 5794 Typical application of 9390 Integrated Distribution Cabinet distributing power to IT racks 480V input and 208 120V output with BIB...

Page 14: ...r from the UPS when using maintenance bypass to supply the load Features Line and match design Two three or four breaker maintenance bypass No internal transformers Smallest cabinet ships bolted to UP...

Page 15: ...for 42 pole panelboard IAC D with dead front removed Distribution breakers electronic adjustable with 250A sensors 100 250A with 100A sensors 40 100A IAC D Distribution Cabinet Two UPS parallel config...

Page 16: ...EMS The EMS pro vides state of the art monitoring and alarming provisions that allow you to monitor power con sumption and quality manage and plan power needs and react quickly to any potential proble...

Page 17: ...e out fan trays Input Output connections DC connections Bottom cable entry area Modular static switch assembly Redundant power supplies 160 kVA X Slot communication bays System control and interface b...

Page 18: ...es Space savings Ease of installation small footprint no floor load con cerns no burden on tem perature control systems no hazardous materials Reliability flywheel systems can be used in conjunction w...

Page 19: ...stribution Quantity 2 maximum Voltage 208 120V Main breaker 225A 65 kAIC Circuits 84 maximum Distribution in lieu of panelboards breakers Quantity 6 maximum Voltage 208 120V Size 250A 65 kAIC adjustab...

Page 20: ...SNMP X Card with an Environment Monitoring Probe Two commu nications bays standard Maximum of four communication bays with the communication expansion option The following connectivity options can be...