EATON CORPORATION  

 

Eaton 9390 Uninterruptible Power System

Integrated 
Accessory 
Cabinets for 
customizable 
configurations

Eaton offers several configura-
tions of Integrated Accessory 
Cabinets (IAC) for use with the 
9390 UPS. Major functions of 
the IAC include: maintenance 
bypass, parallel tie capability and 
power distribution with combi-
nations up to (2) 42-pole panel-
boards and (6) sub-feed breakers 
per IAC.

The IAC is primarily available in 
two forms – either a 200 mm 
(8”) sidecar bolted to the UPS 
(maintenance bypass or tie) or 
a 570 mm (22.5”) free-standing 
cabinet (maintenance bypass, tie 
or distribution). The size of the 
IAC is primarily dependant on 
function and rating.

IAC-SB and IAC-B 
Maintenance bypass

Maintenance bypass configura-
tion (MBP) and maintenance 
isolation (MIS) breakers enable 
power to completely bypass the 
UPS power module. The module 
can then be serviced safely or 
replaced without interrupting 
power to critical systems. An 
optional bypass breaker (BIB) 
and rectifier input breaker (RIB) 
provide a single wiring point 
input to the UPS as well as a 
convenient method for removing 
power from the UPS when using 
maintenance bypass to supply 
the load.

Features

•  Line and match design

•  Two, three or four-breaker 

maintenance bypass

•  No internal transformers

•  Smallest cabinet ships bolted 

to UPS (IAC-SB)

•  Large cabinet can be remote-

ly located (IAC-B)

IAC-ST and IAC-T 
Tie Cabinet

•  Parallel UPS tie cabinet 

(redundant). See one-line 
diagram on next page.

•  Two-breaker tie with mainte-

nance bypass (IAC-T only)

• Two-breaker tie-with 

main output

• Two-breaker tie

• Wall-mounted maintenance 

bypass, tie and distribution 
panels are also available

IAC-B Maintenance 
bypass (160 kVA)

Rectifier input 
(not shown)

Bypass input

Bypass breaker

UPS output 
(isolation)

System load 
breaker (SLB)

UPS #2 output 
(MOB 2)

UPS #1 output 
(MOB 1)

IAC-T Parallel Tie Cabinet

8”

22.5”

160 kVA 208V

IAC-B

80 kVA 208 & 

480V

160 kVA 480V

IAC-SC

IAC-D Distribution 
Cabinet

•  Used to add (2) additional 

42-pole panelboards

Or

•  (1) 42-pole panelboards and 

up to (3) 250A distribution 
breakers

Or

•  Up to (6) 250A distribution 

breakers

•  Line and match or remote

•  Casters and leveling feet

•  Panelboards come with indi-

vidual 225A main breaker

•  Neutral rated for harmonic 

loads (200%)

•  Distribution breakers are 

Eaton JG electronic trip
-  Two electronic sensors 
  available 100A and 250A
-  100A settings 40-100A trip 
 (eight 

settings)

-  250A setting 100-250A trip 
 (eight 

settings)

Summary of Contents for Powerware 9390

Page 1: ...PowerChain Management solutions 20 160 kVA Eaton 9390 UPS...

Page 2: ...2 EATON CORPORATION Product Catalog Eaton 9390 20 160 KVA...

Page 3: ...e power system UPS is a double conversion UPS that resolves all utility power problems and supplies clean continuous uninterruptible power to connected equipment Whether you re selecting a UPS for a b...

Page 4: ...86 88 90 92 94 96 98 94 65 Load Eaton 9390 160 kVA Efficiency Curve Efficiency Operational savings Efficiency comparison Efficiency difference 2 3 4 1 year 5 years 1 year 5 years 1 year 5 years Savin...

Page 5: ...eading Lagging 1 0 75 0 50 0 25 0 0 25 0 50 0 75 1 kVAr kW PF 0 9 100 kW PF 1 PF 0 9 PF 0 8 Without derating 1 0 75 0 50 0 25 Many competitive UPSs cannot operate in this range without significant der...

Page 6: ...is configuration is a compact 164 6 inches Tie Cabinet 160 kVA UPS Modules Battery Battery ping To address these concerns for reliability the degree of autonomy and the complexity of implementation Ho...

Page 7: ...floor space requirements Advanced battery management optimizes battery performance and service life Eaton s ABM technology uses a unique three stage charg ing technique that significantly extends batt...

Page 8: ...itical alarm notification and monthly reports on UPS battery health 7x24 technical support access In addition to the warranty and first year of on site coverage Eaton offers a wide variety of support...

Page 9: ...titive advantage If your company is like most its power system was built over time As the organization s needs changed additional equip ment was likely retrofitted into the system with a circuit break...

Page 10: ...for your needs Medical imaging and equipment protection Having been tested and certified for use in medical imaging system applications by all major suppliers of X ray MRI and CT machines the 9390 me...

Page 11: ...ith a three year warranty other battery configurations are available with a one year warranty Serviceability Front access only design and top bottom cable entry provides installation flexibility and e...

Page 12: ...ith this optional cabinet Eaton offers a complete one stop shop for power protection and distribution solutions that is easy to design install custom ize and manage while deliver ing pay as you grow s...

Page 13: ...13 www eaton com powerquality 1 800 356 5794 Typical application of 9390 Integrated Distribution Cabinet distributing power to IT racks 480V input and 208 120V output with BIB...

Page 14: ...r from the UPS when using maintenance bypass to supply the load Features Line and match design Two three or four breaker maintenance bypass No internal transformers Smallest cabinet ships bolted to UP...

Page 15: ...for 42 pole panelboard IAC D with dead front removed Distribution breakers electronic adjustable with 250A sensors 100 250A with 100A sensors 40 100A IAC D Distribution Cabinet Two UPS parallel config...

Page 16: ...EMS The EMS pro vides state of the art monitoring and alarming provisions that allow you to monitor power con sumption and quality manage and plan power needs and react quickly to any potential proble...

Page 17: ...e out fan trays Input Output connections DC connections Bottom cable entry area Modular static switch assembly Redundant power supplies 160 kVA X Slot communication bays System control and interface b...

Page 18: ...es Space savings Ease of installation small footprint no floor load con cerns no burden on tem perature control systems no hazardous materials Reliability flywheel systems can be used in conjunction w...

Page 19: ...stribution Quantity 2 maximum Voltage 208 120V Main breaker 225A 65 kAIC Circuits 84 maximum Distribution in lieu of panelboards breakers Quantity 6 maximum Voltage 208 120V Size 250A 65 kAIC adjustab...

Page 20: ...SNMP X Card with an Environment Monitoring Probe Two commu nications bays standard Maximum of four communication bays with the communication expansion option The following connectivity options can be...

Reviews: