9
ONGUARD COMMAND CONSOLE INSTALLATION MANUAL
www.eaton.com/onguard
OnGuard Command Console
Installation Manual
SECTION III - Assembling the Console
2� Assemble front worksurface stiffener to support frames
with (2)
1
⁄
4
"
x ½" self-threading hex head screws�
C. Install and Connect the Lift Motor Components
1� Plug the power supply cable into the lift control box
receptacle� Loop the power supply cable into the “U”
shaped strain relief slot on control box� Then attach
control box to front worksurface stiffener with (2) #10 x
1 -
3
⁄
4
" self-threading screws, as shown in figure C�1�
2� Route the power cord from the control box into the left
support frame channel, and then through the center
worksurface support frame, as shown in figure C�2�
A x 2
D x 2
“U” Strain
Relief Slot
Route Cable Through
Channel Openings
Hardware required
Hardware required
C�1
C�2