5 Installation
5.4 Mounting
MICRO PANEL XV-152
12/2011 MN04802006Z-EN
www.eaton.com
47
3
If no sealing strip is glued in the groove (A) on the rear of the device front plate, insert the sealing
strip supplied in the groove (A) and cut it so that the join is tight.
4
Fit the supplied threaded pins in the retaining brackets beforehand.
5
Fit the device from the front into the mounting cutout.
6
Clip on the retaining brackets in the recesses provided for them on the device as shown below and
fix the device by tightening the threaded pins until the front of the MICRO PANEL is flush with the
surface of the control cabinet at the fixing points.
CAUTION
Poor sealing
Poor sealing resulting from the twisting of the sealing strip or due to a gap between
the ends of the sealing strip.
The join of the sealing strip must be positioned on the bottom of the device.
Do
not
twist the sealing strip when it is inserted.
Cut the sealing strip to a suitable length so that the join is tight.
Fig. 26 Groove for sealing strip (A)
Fig. 27 Threaded pin pre-fitted in a retaining bracket
CAUTION
Mechanical damage to the device
Tightening the threaded pins too tightly may damage the device.
Tighten threaded pins with a max. tightening torque of 0.2 Nm.