•  NOT suitable for ground mount installation.
•  Fixture should be installed by persons with experience in household wiring or by a 

qualified electrician. The electrical system, and the method of electrically connecting 

the fixture to it, must be in accordance with the National Electrical Code and local 

building codes.

•  Do not allow sensor head to touch light housing – maintain at least 

1 in. space between fixture and sensor.

•  Keep away from flammable objects. Do not position fixture within 2 in.

of any combustible materials.

•  For proper operation and protection against damage, the motion sensor head 

adjustment knobs must be facing the ground.

•  This device complies with Part 15 of the FCC Rules. Operation is subject to the 

following two conditions: (1) This device may not cause harmful interference, and (2) 
this device must accept any interference received, including interference that may cause 
undesired operation. Under Part 15   of the FCC Rules, any changes or modifications to 
the motion detector described in this instruction sheet that are not expressly approved 
by Eaton could void the user’s authority to operate the equipment.

         WARNING: FCC Regulations state that any unauthorized changes or  
         modifications to this equipment not expressly approved by the manufacturer  
         could void the user’s authorization to operate this equipment.

SAVE THESE INSTRUCTIONS.

FOR BEST RESULTS

•  Install the motion sensor/transmitter 8-12 feet 

  above the ground. (Motion sensor is less sensitive 

  above 12 feet.)
•  Locate motion sensor so motion moves across 

  detection zone (Fig. 1).
•  Locate sensor away from heat producing sources to

  prevent false triggering. Also be very careful not to 

  include objects such as windows, white walls and

  water in the detection zone.
•  Locate sensor away from moving objects such as trees, large shrubs and street traffic.
•  Do not install more than one motion activated floodlight on one wall switch or the same  

  circuit sincethis may cause interference between fixtures.

MOUNTING AND WIRING YOUR FIXTURE

 WARNING: Risk of electric shock. Disconnect power at fuse or circuit breaker before 

installing or servicing.
NOTE:

 Fixture can be wall or eave mounted.

NOTE:

 Coverplate mounts to recessed mounted standard junction boxes (Fig. 2). Junction box 

must be at least 1-1/2 inch in depth for proper installation for recessed mount application.

1. 

Turn off power at main fuse/breaker box.

2. 

Match up screw holes on the floodlight coverplate 

PACKAGING CONTENTS/CONTENIDO DEL PAQUETE

ITEMS REQUIRED

 

(Purchase separately)

•  Phillips screwdriver
•   Hammer
•  Outdoor weatherproof silicone caulking
•  (2) 150 watt (MAX) PAR 38 floodlight bulbs

NOTE:

 This fixture was designed to work with up to 150 watt maximum PAR halogen flood 

bulbs. For improved energy efficiency, lower wattage PAR halogen flood bulbs may be used. 

Compact Fluorescent (CFL) bulbs contain electronics which may interfere with the motion 

sensing function of your fixture and are not recommended. 

HOW IT WORKS

Your motion activated floodlight senses heat images from 

objects such as people, large animals and automobile engines. 

When motion is detected, the lights will automatically turn 

on. Once motion has stopped, the lights will turn off after a 

preselected time delay. Your motion activated floodlight may 

also be used as a standard floodlight.

IMPORTANT SAFETY INSTRUCTIONS

  When using product, basic precautions should always be followed, including the following:

•  Heed all warnings, including below warnings AND those included on product.
•  Save these instructions and warnings.
•  For outdoor use only.
•  cULus LISTED for wet location.
•  Disassembly of your fixture will void the warranty.
•  Your fixture is prewired and preassembled for easy installation.

•  Read and follow these instructions.

•  To reduce the risk of a burn during relamping, disconnect power supply to the unit 

before relamping.

•  Always use or replace bulb with the same wattage or lower wattage than 

required. Installing a bulb of a higher wattage could create a fire hazard and will  

void the warranty.

CAUTION

•  Connect fixture to a 120 volt, 60 Hz power source. Any other connection voids 

the warranty.

•  Mount fixture to a grounded, recessed-mounted standard junction box marked for use 

in wet locations.

MS34 (Black)

MS34W (White)

 ENGLISH

Up to

50 feet

110 degrees

D.

  (2) #6 and (2) #8 mounting screws 

   (use the size that fits your junction box)
   (2)  vis nº 6 et (2 )vis nº 8 pour boîte de jonction

  

(choisissez la dimension convenant à votre   

   boîte de jonction)
   (2) Tornillos #6 y (2) tornillos #8 de montaje

  

(utilice el tamaño que mejor se adecue a 

   su caja de conexión) 

A.

  Motion detector 

  and light fixture
  Luminaire avec détecteur de 
 mouvement
  Detector de movimiento 

  y accesorio

B.

  Coverplate gasket

  Joint de plaque de recouvrement
  Junta de la placa de cubierta

C.

  (2) Lampholder gaskets 

  (2) joints statiques pour douille
   (2) Juntas obturadoras 
    del receptáculo

E.

  (3) Wire nuts

   (3) capuchons de connexion
   (3) Conectores del cables

WARNING

1

Summary of Contents for HALO MS34

Page 1: ...d mount application 1 Turn off power at main fuse breaker box 2 Match up screw holes on the floodlight coverplate PACKAGING CONTENTS CONTENIDO DEL PAQUETE ITEMS REQUIRED Purchase separately Phillips screwdriver Hammer Outdoor weatherproof silicone caulking 2 150 watt MAX PAR 38 floodlight bulbs NOTE This fixture was designed to work with up to 150 watt maximum PAR halogen flood bulbs For improved ...

Page 2: ...g objects such as trees traffic etc Reposition the sensor Light continuously blinks ON and OFF at night The light given from the unit s own lamp is affecting the photo eye in sensor Light could be reflecting off of nearby surface Re aim the lamp Reposition motion sensor Light is ON during the day The switch on the bottom of the motion sensor is in the test T mode Refer to OPERATING YOUR FIXTURE Th...

Page 3: ...ion ou altération apportée à cet équipement n étant pas expressément approuvée par le fabricant peut annuler le droit de l utilisateur à faire fonctionner cet équipement CONSERVEZ CES INSTRUCTIONS POUR DES RÉSULTATS OPTIMAUX Installez le détecteur de mouvements ou le trans metteur de 2 4 m à 3 7 m 8 à 12 pi au dessus du sol Le détecteur de mouvements est moins sen sible au dessus de 3 7 m ou 12 pi...

Page 4: ... EATON FAISANT L OBJET DE LA RÉCLAMATION AU TITRE DE LA PRÉSENTE GARANTIE AUCUN FRAIS DE MAIN D OEUVRE NE SERA REMBOURSÉ POUR ENLEVER OU INSTALLER UN LUMINAIRE Pour faire une réclamation au titre de la garantie veuillez appeler Eaton au 1 800 334 6871 en choisissant l option 2 pour le Service à la clientèle ou envoyer un courriel à Consumer Products eaton com et fournir les renseignements ci après...

Page 5: ...ERTENCIA Riesgo de choque eléctrico Antes de la instalación o reparación desconecte la alimentación eléctrica en el fusible o interrupto automático GUARDE ESTAS INSTRUCCIONES Hasta 50 pies 110 grados 1 ADVERTENCIA PARA OBTENER LOS MEJORES RESULTADOS Instale el sensor de movimiento transmisor a 2 45 3 65 m 8 12 pies de altura sobre el suelo por encima de 3 65 m 12 pies el sensor de movimiento es me...

Page 6: ... en la zona de detección Asegúrese de que el sensor no esté reaccionando a objetos móviles tales como árboles tráfico etc COMPRUÉBELO USTED MISMO Cubra la lente del sensor con la cinta aislante negra para evitar que detecte movimiento y también cubra la foto celda en la base de la cabeza del detector Si la luce permanecen apagado hay algo en el área de detección que está activando el sensor Cambie...