670
02/16 MN05013001Z EN
Digital inputs 24 V DC
ES4P…
Number
14
Status indication
LCD display (if
provided)
Potential isolation
To power supply
No
Between each other
no
to the outputs
yes
to PC interface, memory card, easyLink
No
to network easyNet
yes
Rated operational
voltage
U
e
V DC
24
At signal ”0”
U
e
V DC
< 5
At signal ”1”
U
e
V DC
> 15.0
Input current at signal "1"
IS1 to IS14
mA
5.7 (at 24 V DC)
Hardware delay time from 0 to 1
Debounce ON
ms
24
Debounce OFF
ms
0.06 (IS1, IS2)
0.17 (IS3 to IS14)
Hardware delay time from 1 to 0
Debounce ON
ms
24
Debounce OFF
ms
0.08 (IS1, IS2)
0.22 (IS3 to IS14)
Cable length (unscreened)
m
100
Single cable length of test signal
output to the device input (shielded)
m
1000