28

OVERALL DIMENSIONS

WARRANTY:  Eaton warrants all products against defects in mate-
rial and workmanship for a period of one (1) year  from the date of
shipment to Buyer. This is a limited warranty limited to its terms. This
warranty is void if the product has been altered, misused, taken apart
or otherwise abused. ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED, ARE EXCLUDED, INCLUDING BUT NOT LIMITED TO
THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FIT-
NESS FOR PURPOSE.

BUYERS' REMEDIES:  Eaton's obligations and liabilities under the
foregoing warranty are limited to repair or replacement of the product
without charge. To receive the required Return Goods Authorization
number (RGA), contact your local Durant distributor or Durant Repair
Department at 800-540-9242. A charge is made for repairing after
the expiration of the warranty. IN NO EVENT SHALL EATON BE
LIABLE FOR CLAIMS BASED UPON BREACH OF EXPRESS OR
IMPLIED WARRANTY OR NEGLIGENCE OR ANY OTHER DAM-
AGES WHETHER DIRECT, IMMEDIATE, FORESEEABLE, CON-
SEQUENTIAL OR SPECIAL OR FOR ANY EXPENSES INCURRED
BY REASON OF THE USE OR MISUSE, SALE OR FABRICATION
OF PRODUCTS WHICH DO OR DO NOT CONFORM TO THE
TERMS AND CONDITIONS OF THIS CONTRACT.

INDEMNIFICATION:  Buyer agrees to hold Eaton harmless from,
defend, and indemnify Eaton against damages, claims and ex-
penses arising out of subsequent sales of Durant products or
products containing components manufactured by Eaton and based
upon personal injuries, deaths, property damage, lost profits, and
other matters for which Buyer, its employees or sub-contractors are
or may be to any extent liable, including without limitation penalties
imposed by the Consumer Product Safety Act (P.L.92-573) and
liability imposed upon any person pursuant to the Magnuson-Moss
Warranty Act (P.L.93.637), as now in effect or as amended hereafter.
The warranties and remedies provided for herein are available to
Buyer and shall not extend to any other person.

COMPLIANCE WITH OSHA:  Eaton offers no warranty and makes
no representation that its products comply with the provisions or
standards of the Occupational Safety and Health Act of 1970, or any
regulations issued thereunder. In no event shall Eaton be liable for
any loss, damages, fines, penalty or expense arising under said
ACT.

This manual constitutes proprietary information of Eaton Corp., and
is furnished for the customers' use in operating the Ambassador
Series Count Control. Reproduction of this material for purposes
other than the support of the Ambassador Series Control or related
products is prohibited without the prior written consent of Eaton
Corp., Watertown, WI.

In the construction of the Control described herein, the full intent of
the specifications will be met. Eaton Corp., however reserves the
right to make, from time to time and without proper written notice,
such departures from the detail specifications as may be required to
permit improvements in the design of the product.

The information included herein is believed to be accurate and
reliable, however no responsibility is assumed by Eaton Corp., for its
use; nor for any infringements of patents or other rights of third
parties which may result from its use.

This equipment is capable of generating  radio frequency energy.  If
not installed and used in accordance with the instructions, this unit
may interfere with radio communications.

1

12

2

3

4

5

6

7

8

9

10

11

1

2

3

4

5

6

7

8

9

10

5.60" 

±

 .03"

(142.24MM 

±

 .76MM)

2.946" 

±

 .015"

(74.83MM 

±

 .38MM)

PANEL CUTOUT

MAX. PANEL

THICKNESS

.500 (12.7MM)

2.677" 

±

.028

(68.00MM 

±

.70MM)

2.946" 

±

 .015"

(74.83MM 

±

 .38MM)

2.677" 

±

.028

(68.00MM 

±

.70MM)

RST
CLR

RUN
PGM

PRNT

EXIT

ENT

SEL

Durant

®

Gasket

Summary of Contents for Durant AMBASSADOR Series

Page 1: ...duction 3 Front Panel Features 4 Run Mode Operation 5 Programming 12 Scale Factors 13 Rear Terminal Description 15 Wiring 18 Serial Communications 24 Diagnostics and Troubleshooting 26 Specifications...

Page 2: ...hod eventtimemeasure ment and can calculate and scale the rate so that even a low count speed 1 Hz can yield accurate rates in engineering units ft sec gal min etc The rate feature operates simulta ne...

Page 3: ...et output The main counter counts in the opposite direction if it is programmed to reset to preset BATCH COUNTER Counts up when main counter reaches the main preset Every two milliseconds the batch co...

Page 4: ...ues Reset Clear Key In the run mode this key can be programmed to reset count values In the preset editing mode this key zeros pre sets that are being changed In the program mode it zeros numeric data...

Page 5: ...formation to the operator and does not affect the operation of the control If power is removed and restored the unit will power up with the display that was last selected RUN MODE MENUS The keystroke...

Page 6: ...rn to the last run mode menu ENTERING THE PROGRAM MODE Press OVERVIEW OF MAIN MENUS Select count mode reset to zero or reset to preset and auto recycle op erations Select the input function to be per...

Page 7: ...igit HELP programs decimal point SEL selects decimal point position HELP SEL selects decimal point position HELP Select Count Input mode using the UP and DOWN cursors to scroll thru this menu CONTACT...

Page 8: ...INPUT 1 STOP CNT INPUT 1 LOCK PGM INPUT 2 DISABLED INPUT 3 DISABLED INPUT 4 DISABLED Output Control Reset Counter Edge triggered Reset Counter Level sensitive Reset Batch Edge triggered Reset Totaliz...

Page 9: ...1 D0 Drop Outoutput Enter output pulse time XX XX seconds SEL SEL SEL MAIN MENU SUB MENU VIEW MENU EDIT MENU Selection repeats as for P1 above Selection repeats as for P1 above Selection repeats as fo...

Page 10: ...KIP or SEND for each data block to be transmitted when requested by the host computer RST KEY DISABLED USER PROGRAM SEL PROGRAM OPTIONS SEL RST KEY DISABLED RST KEY RS C EDG RST KEY RS C LVL RST KEY R...

Page 11: ...als SOLID ST C x2 DIR same as above except counts occur on both edges of input signal for increased resolution RESET TO ZERO the main counter resets to zero when a main counter reset occurs The normal...

Page 12: ...nd transistor output 2 sub menus SERial PORT SER PORT ID enter the desired two digit serial ID number DESCRIPTION OF PROGRAM OPTIONS 00 99 decimal All communications to the control must contain this n...

Page 13: ...the count scaler required to indicate material usage in 1 100 s of feet XXXX XX 100 CS 0 83333 120 Select the XXXX XX position on the counter decimal point menu RATE SCALING The 1 Tau rate meter calc...

Page 14: ...C Common when picked up For maxi mumnoiseimmunity thegroundterminalmustbeconnected to a good earth ground All shielded signal cables should be connected to earth ground or ground on the counter 5 6 an...

Page 15: ...nput signal On input B requires a current sourcing input signal Switch 3 Input A threshold level Off high threshold level use with DC sensors On low threshold level use with mag pickups Turn switch 1...

Page 16: ...act Count Input 1 12 2 3 4 5 6 7 8 9 10 11 13 14 15 16 17 18 19 20 21 22 Dotted lines indicate which inputs may be wired in this manner Typically a separate sensor is used for each input Control input...

Page 17: ...d in the same manner Do not connect Term 1 if sensor is powered from another power supply Wire colors shown correspond to Cutler Hammer inductive proximity and photo sensors Dip switches 1 and or 2 ON...

Page 18: ...or a single channel encoder All dip switches OFF This wiring example shows the load being controlled from the normally open contacts of Relay 1 Wiring for the normally closed contacts 8 9 would be don...

Page 19: ...I code with the RS 485 serial specifi cation and Opto 22 compatible protocol This allows bi directional communications and addressing of multiple con trols on a single two wire communication bus Each...

Page 20: ...ERIAL COMMAND RESPONSE FORMAT responds by sending an ASCII N not acknowledged followed by a one character error code and a carriage return Error Codes 00 Power up Error When power is applied to the un...

Page 21: ...store lock commands when power is removed The host must re issue the desired lock command after power is re applied Lock inputs are not affected by serial lock commands If both a lock input and a seri...

Page 22: ...by a two or three digit number representing the desired sub menu see diagram on pages 22 and 23 for sub menu numbers The counter responds by transmitting a number representing the current option selec...

Page 23: ...102 103 104 105 106 107 108 RESET TO AUTO CYC ZERO P1 DISABLED P1 0 11 12 110 111 120 121 INPUTS PROGRAM INPUT 1 INPUT 2 INPUT 3 INPUT 4 Next item is PROGRAM SER PORT on next page OUT MODE PROGRAM RE...

Page 24: ...ATE SER PORT ID BAUD PARITY Tx DELAY 0 002 0 100 SEND SKIP SEND SKIP SEND SKIP SEND SKIP SEND SKIP READ RPI 40 41 42 43 50 51 52 53 54 410 411 412 413 420 421 422 430 431 500 501 530 531 510 511 520 5...

Page 25: ...ess the front panel reset key This will reset all user programmable options to the factory default settings and rerun all tests 3 If the same error occurs again there is a malfunction within the count...

Page 26: ...ts peak to peak If it is less the sensor is defective or the target is too far from the sensor or the target is not moving fast enough III Error Message On Display The message ERROR followed by a sing...

Page 27: ...eed Mode Solid state Contact Inp A Inp B high speed low speed Add Sub 20 kHz 40 Hz Add Add 20 kHz 40 Hz Count Direction 15 kHz 40 Hz Count x 2 Direction 7 5 kHz N A Quadrature 6 5 kHz N A Quadrature x...

Page 28: ...xx Medium Duty single channel Shaft Encoder 38151 xxxx Medium Duty quadrature Shaft Encoder 48370 xxxx Heavy Duty single channel Shaft Encoder 48371 xxxx Heavy Duty quadrature Shaft Encoder ES9513 RS...

Page 29: ...posed upon any person pursuant to the Magnuson Moss WarrantyAct P L 93 637 asnowineffectorasamendedhereafter The warranties and remedies provided for herein are available to Buyer and shall not extend...

Page 30: ...Printed in U S A Durant 901 South 12th Street Watertown WI 53094 920 261 4070 800 540 9242 FAX 920 261 9097...

Reviews: