Effective.June.2007

 

 

Page 3

RS-485 PONI

66A2070 Rev. B

3d. Mounting to an MP-4000

To mount an RS-485 PONI onto the MP-4000, use the 

U-shaped mounting bracket and #6 32 x ¼” pan head 

screws supplied with the MP-4000. Use this bracket only 

when a URTD is not mounted to the MP-4000. If a URTD is 

mounted on the MP-4000, the RS-485 PONI can piggy back 

directly on the URTD. The machine screws supplied with 

the RS-485 PONI are then used to screw into the molded 

plastic mounting-holes of the URTD. Refer to the MP-4000 

Instruction Book IB02602002E for additional information. To 

order this mounting bracket use part number 7066C H0.

Figure 6: Mounting to an MP-4000

3e. Mounting to an ATC-400

To mount the RS-485 PONI to the rear of the ATC-400, use the 

stacking screws that are shipped with the RS-485 PONI. On the 

rear panel of the ATC-400, there are two treaded holes that are 

to be used for attaching PONI type devices. Refer to Figure 7.

Figure 7: Mounting to an ATC-400

Mount the RS-485 PONI with the label facing up, the RS-485 

connector on the left and the ribbon cable on the right, as 

you are facing the rear panel of the ATC-400.

Attach the ribbon cable from the RS-485 PONI to the 

receptacle of the IQ device, as shown in Figure 3 on Page 2, 

and firmly tighten the screws on the plug lock assembly.

3f. Mounting to an IQ Transfer II

To mount the RS-485 PONI to the rear of the IQ Transfer II 

use the stacking screws that are shipped with the RS-485 

PONI. On the rear panel of the IQ Transfer II, there are two 

sets of threaded holes that are to be used for attaching PONI 

type.devices .

Use either set for mounting the RS-485 PONI. Refer to 

Figure 8. Mount the RS-485 PONI with the label facing up, 

the RS-485 connector on the left and the ribbon cable on the 

right, as you are facing the rear panel of the IQ Transfer II.

Attach the ribbon cable from the RS-485 PONI to the 

receptacle of the IQ device, as shown in Figure 3 on Page 2, 

and firmly tighten the screws on the plug lock assembly.

Figure 8: Mounting to an IQ Transfer II

Simplified Wiring Rules

The RS-485 PONI provides the user with a half-duplex 

EIA/RS-485 network connection. EIA/RS-485 is a multi-drop 

industrial-grade communications standard.

It is a “balanced differential” signal which uses a twisted-pair 

containing the “A” and “B” signals and a common. For this 

reason, it is very important to carry all three conductors to 

help ensure a high-quality communications network.

Summary of Contents for Cutler-Hammer

Page 1: ...66A2070 Rev B For more information visit www eaton com Effective June 2007 Instruction Leaflet 66A2070 INSTRUCTIONS FORTHE RS 485 PONI Cutler Hammer...

Page 2: ...ommunications Protocol 5 Function Codes 5 Control of Host Product 5 Register Access Configurations 6 Energy Format 6 Exception Codes 6 INCOM Protocols 6 Supported Diagnostic Sub Functions 6 Troublesho...

Page 3: ...ud rates are selectable for networking flexibility Addresses 0 99 are selectable by way of two rotary switches Status light provides indication of proper operation and also functions as an error indic...

Page 4: ...00 s style s 66D2040Gxx do not have external power supply fuses These new style meters do not require the Amp fuse included 3b Mounting to the IQ DP 4000 or IQ Data Plus II Mounting to the IQ DP 4000...

Page 5: ...the ATC 400 Attach the ribbon cable from the RS 485 PONI to the receptacle of the IQ device as shown in Figure 3 on Page 2 and firmly tighten the screws on the plug lock assembly 3f Mounting to an IQ...

Page 6: ...485 PONI to host devices where the mounting surfaces are tied to the chassis ground the Chassis ground connection on the RS 485 PONI should not be connected Using the metal screws provided will ensur...

Page 7: ...NI to an host product is listed in Figure 11 on Page 6 The Modbus master reads the INCOM product response to a pass through query using either function code 03 or 04 beginning at register 424833 61001...

Page 8: ...ction in the query is not supported by the RS 485 PONI exception code 01 is returned in the response If the data object register is illegal exception code 02 is returned in the response If the data va...

Page 9: ...PONI address Error Detection Using Status LED If the status light blinks twice in rapid ON OFF cycles followed by a 1 5 second OFF period this is an indication that the product is not being recognize...

Page 10: ...011 1998 Radiated and Conducted Emissions System Ratings Operating Temperature 20 C to 60 C Storage Temperature 20 C to 70 C Altitude 3 048 m 10 000 ft Operating Humidity 5 to 90 max non condensing En...

Page 11: ...6177 1220 1820 10 peak IB demand A 404643 406179 1222 1822 10 peak IC demand A 404645 406181 1224 1824 10 peak IG demand A 404647 406183 1226 1826 10 peak IN demand A 404649 406185 1228 1828 10 power...

Page 12: ...727 406263 1276 1876 1 x x lead KVARh 404729 406265 1278 1878 1 x x lag KVARh 404731 406267 127A 187A 1 x x net KVARh 404733 406269 127C 187C 1 x x x Energy 32 bit apparent KVAh 404735 406271 127E 187...

Page 13: ...4 Device Alarmed 21 Phase C Alarm 5 Device On 22 Neutral Alarm 6 Device Off 23 Ground Earth Alarm 7 Device Ready 24 Phase AB Alarm 8 Device Starting 25 Phase BC Alarm 9 Device Running 26 Phase CA Alar...

Page 14: ...0 Secondary status unknown Reserved 9 27 1 Secondary status is not applicable 2 Device in program mode 3 Device in test mode 4 Device disabled 5 Device disarmed 28 Product Specific Code 28 6 Controlle...

Page 15: ...izing 92 Multiple External Conditions 131 Starts Per Hour 93 Motor Bearing Temperature 132 Preferred Source 94 Load Bearing Temperature 133 Plant Exerciser 95 Auxiliary Temperature 134 Neutral Ground...

Page 16: ...y Moon Township PA 15108 4312 USA www eaton com 2005 2007 Eaton Corporation All Rights Reserved Publication No 66A2070 Rev B June 2007 Cutler Hammer Contact Information Power Quality Technical Support...

Reviews: