background image

All  statements,  technical  information  and  recommendations  contained  herein  are  based  on  information  and  tests  we  believe  to  be  reliable.  The  accuracy  or 

completeness thereof are not guaranteed. In accordance with Crouse-Hinds “Terms and Conditions of Sale,” and since conditions of use are outside our control, 

the purchaser should determine the suitability of the product for his intended use and assumes all risk and liability whatsoever in connection therewith.

       Eaton’s Crouse-Hinds Business                                                                                                 IF 1744
      1201 Wolf Street Syracuse, NY 13208  •  U.S.A.                                                                       Revision 1
       Copyright© 2015                                                                                                                  New 02/15

 

Pendant Mounting (Cable)

1. 

Remove cover from enclosure and let hang by safety chain. 

2.  Remove fixture from conduit and set aside.

3.  Install conduit T onto conduit and install pipe nipple into vertically facing T 

leg.

4.  Install gland into horizontal facing pipe nipple. 

5.  Install conduit T onto conduit and install pipe nipple into vertically facing T 

leg.

6.  Install glands into horizontal facing pipe nipples. 

7. 

Install glands into sensor hubs.

8.  Locate installation location and secure the L-brackets to the wall with 

customer supplied hardware.

9.  Secure L-brackets to the enclosure with included hardware. Torque the 

hardware to 25 in-lbs. (The enclosure provides 4 thru holes at the corners 

for mounting L-brackets.) Note: Sensor lens must face down when 

installed and have an unobstructed view.

10.  Once wired (see wiring instructions), replace the cover and torque the 

provided cover screws with 0-rings until fully seated.

11.  Re-install fixture to conduit T.

Stanchion Mounting

1. 

Remove cover from enclosure and let hang by safety chain. 

2.  Remove Stanchion mount from pole and set aside.

3.  Install conduit T onto top of pole and install pipe nipple into vertically 

facing T leg.

4.  Install gland into horizontal facing pipe nipple. 

5.  Install conduit T onto pipe nipple and install pipe nipple into vertically 

facing T leg.

6.  Install glands into horizontal facing pipe nipples. 

7. 

Install glands into sensor hubs.

8.  Locate installation location and secure the U-bolts and Stanchion Mount 

Brackets to the Stanchion pole using included hardware. Torque the 

hardware to 138 in-lbs.

9.  Secure the L-brackets to the Stanchion Mount Brackets using the included 

hardware. Torque the hardware to 25 in-lbs.

10.  Secure L-brackets to the enclosure with included hardware. Torque the 

hardware to 25 in-lbs. (The enclosure provides 4 thru holes at the corners 

for mounting L-brackets.) Note: Sensor lens must face down when 

installed and have an unobstructed view.

11.  Once wired (see wiring instructions), replace the cover and torque the 

provided cover screws with 0-rings until fully seated.

12.  Re-install Stanchion mount to conduit T.

WIRING INSTRUCTIONS

120/277 VAC

Note: 

The FSP-211 must be grounded to ensure signal integrity, not for safety 

ground.

OPERATING INSTRUCTIONS

For detailed operating instructions consult WattStopper FSP-211 data sheet.

For instructions for selecting custom settings consult WattStopper FSIR-100 

Wireless IR Commissioning Tool data sheet.

Summary of Contents for Crouse-Hinds IF 1744

Page 1: ...nd torque the provided cover screws with 0 rings until fully seated Pendant Mounting Conduit 1 Remove cover from enclosure and let hang by safety chain 2 Remove fixture from conduit and set aside 3 Install conduit T onto conduit and install pipe nipples onto conduit T 4 Mount enclosure to horizontal facing pipe nipple Note Sensor lens must face down when installed and have an unobstructed view 5 O...

Page 2: ... replace the cover and torque the provided cover screws with 0 rings until fully seated 11 Re install fixture to conduit T Stanchion Mounting 1 Remove cover from enclosure and let hang by safety chain 2 Remove Stanchion mount from pole and set aside 3 Install conduit T onto top of pole and install pipe nipple into vertically facing T leg 4 Install gland into horizontal facing pipe nipple 5 Install...

Page 3: ... colgante Conducto 1 Retire la tapa de la carcasa y deje que cuelgue de la cadena de seguridad 2 Retire el accesorio del conducto y colóquelo a un lado 3 Instale el conducto en T en el conducto e instale las boquillas del tubo en el conducto en T 4 Monte la carcasa de manera horizontal mirando hacia la boquilla del tubo Nota Cuando se instalen las lentes del sensor éstas deben mirar hacia abajo y ...

Page 4: ...je del poste al polo del poste utilizando la tornillería incluida Ajuste la tornillería a 138 pulg libras 9 Asegure los soportes en L a los soportes del montaje del poste usando la tornillería incluida Ajuste la tornillería a 25 pulg libras 10 Asegure los soportes en L a la carcasa con la tornillería incluida Ajuste la tornillería a 25 pulg libras La carcasa proporciona 4 orificios pasantes en las...

Page 5: ... leur joint torique jusqu à ce qu il soit complètement en place Fixation suspendue conduit 1 Retirer le couvercle du boîtier et le laisser suspendu à une chaîne de sécurité 2 Retirer le luminaire du conduit et le mettre de côté 3 Installer un T de conduit sur le conduit et un mamelon de tuyauterie sur le T 4 Installer le boîtier sur un mamelon face à l horizontale Remarque une fois le détecteur in...

Page 6: ...ier et le laisser suspendu à une chaîne de sécurité 2 Retirer la fixation du poteau et la mettre de côté 3 Installer un T de conduit sur le dessus du poteau puis un manchon de raccordement dans une branche du T faisant face à la verticale 4 Installer un manchon de raccordement dans un mamelon faisant face à l horizontale 5 Poser un T de conduit sur le manchon de raccordement et installer un mancho...