background image

3

INM F892 Rev 1

20 21 22

17 18 19

14 15 16

11 12 13

23 24 25 26 27 28 29 30 31 32 33 34

Seg 1A

Seg 2A

Seg 3A

Seg 4A

Seg 5A

Seg 6A

Seg 7A

Seg 8A

Power A

1

2

3

4

Power B

Power Module A

Power Module B

F892-CA

Diagnostic Module

Inspect

Clamp

DIN

Clamps

Inspect

Clamps

70 71 72

67 68 69

64 65 66

61 62 63

73 74 75

76 77 78

79 80 81

82 83 84

Segment 1

Segment 2

Segment 3

Segment 4

Segment 5

Segment 6

Segment 7

Segment 8

DIN

Clamps

Inspect

Clamp

www.mtl-fieldbus.com

Relcom

Alm   G  SG

91 92 93 8

Shield Ground

Option

Shields

Rev: F.0

+

S

-

+

S

-

+

S

-

+

S

-

+

S

-

+

S

-

+

S

-

+

S

-

-

+

-

+

44 45 46

41 42 43

38 39 40

35 36 37

47 48 49 50 51 52 53 54 55 56 57 58

Seg 1B

Seg 2B

Seg 3B

Seg 4B

Seg 5B

Seg 6B

Seg 7B

Seg 8B

+

S

-

+

S

-

+

S

-

+

S

-

+

S

-

+

S

-

+

S

-

+

S

-

+

S

-

+

S

-

+

S

-

+

S

-

+

S

-

+

S

-

+

S

-

+

S

-

-

S

+

97 98 99

Diag Seg

94 95 96

Diag Seg

-

S

+

G

A2

A1

SG

 

 

 

    Figure 2 

- F892-CA Carrier

Carriers with date codes 0711 or earlier are only provided with a single row of eight 

connectors (top).  The Diagnostic Segment Connectors were introduced on carriers 

with date codes after 0726.  The Shield Ground Option was added with revision F.0 

(previous version did not carry a revision).  See sections 5.4, 5.6, and 5.8 for further 

details.
 

MECHANICAL

4 .1  Mounting Orientation

The F892-CA carriers are designed for mounting on a horizontally aligned DIN-rail on a 
vertical surface.  This method of mounting ensures optimum heat dissipation from the 
F801 Power Modules.

4 .2  Enclosure Requirements

4 .2 .1  General Requirements

The assembly may be mounted in hazardous (classified) areas – see Sections 8 & 9.  
The following conditions must also be satisfied to ensure safe and reliable operation.

a)  Prevent any form of pollution that could compromise the operation of the unit. 

For example, choose an unpolluted location or a suitable enclosure to protect the 
assembly.

b)  Provide an adequate level of mechanical protection. This can be achieved by 

selecting a protected location, a suitable enclosure, or a combination of both.

Summary of Contents for Crouse-Hinds F892

Page 1: ...MTL F892 8 Segment Redundant Fieldbus Power Supply for use with non proprietary cabled systems March 2022 INM F890 Rev 1 Instruction manual MTL fieldbus networks...

Page 2: ...ii INM F892 Rev 1 THIS PAGE IS LEFT INTENTIONALLY BLANK...

Page 3: ...5 5 ELECTRICAL CONNECTIONS 5 5 1 DC Power Requirements 6 5 2 Power A and Power B 7 5 2 1 Redundancy 7 5 2 2 Terminator 7 5 3 Alarm Connection 7 5 4 FInal Segment Connections 8 5 5 Field Segment Connec...

Page 4: ...incorporated into each Power Module A single F801 or F802 module may be used where redundancy is not required 2 DESCRIPTION For maximum reliability the module carrier contains no components and only...

Page 5: ...is lit Redundant 24V DC nom input power is connected to the F892 CA carrier using two part pluggable connectors Field wiring connections are available with either pluggable screw terminals F892 PS or...

Page 6: ...ith a single row of eight connectors top The Diagnostic Segment Connectors were introduced on carriers with date codes after 0726 The Shield Ground Option was added with revision F 0 previous version...

Page 7: ...at DIN rail to EN50022 and uses six built in DIN clamp tabs to hold it on the rail The F801 power modules must be removed from the carrier to obtain access to the DIN rail clamp screws 4 3 1 Mounting...

Page 8: ...To remove a Power Module support the module while unscrewing the four retaining screws at its base Lift the module off the carrier connector Note Earlier versions of the module carriers do not have l...

Page 9: ...vided allowing the use of bulk power supplies with a supply range of 19 2 30VDC Input power cabling and over current protection devices must be chosen to match the current consumption An F892 system o...

Page 10: ...Power Module B connector to allow the alarm circuit to function Power must be connected to Power B terminals if live replacement of Power Module A is necessary since Power B terminals feed the Power...

Page 11: ...so only one connection should be made from the Termblock to the F892 carrier Other systems such as the ABB 800xA or the Rosemount 3420 use the power supply carrier to make the interconnection between...

Page 12: ...r the jumper The carrier is delivered with the jumper installed as shown in figure 7b As indicated in the text on the jumper the screens are isolated To tie the 8 screens together and route them to th...

Page 13: ...eg S 98 Diag Seg S 96 Diag Seg 99 Diag Seg 6 TESTING 6 1 F801 Status and Alarm LEDs The F801 or F802 Power Modules are fitted with nine LEDs eight to indicate segment status and one to signify an Alar...

Page 14: ...11 INM F892 Rev 1 8 FM CONTROL DRAWINGS...

Page 15: ...ed in place of the missing F801 or F802 module 24VDC Power Supplies may be installed in the Non hazardous area Vmax 24VDC F801 30VDC F802 24VDC Power Supply A 24VDC Power Supply A This is a Chassis Gr...

Page 16: ...clause 4 2 of EN 60079 17 b This equipment has been designed to provide protection against all the relevant additional hazards referred to in Annex II of the directive such as those in clause 1 2 7 c...