background image

Questions?/Des questions?/¿Preguntas? 1-800-334-6871 [email protected]

1

PACKAGING CONTENTS/CONTENU DE L’EMBALLAGE/CONTENIDO DEL PAQUETE

Instruction Manual/Instrucciones

in wet locations.

•  Suitable for wall mount or eave mount only. NOT suitable for ground mount installation.
•  Fixture should be installed by persons with experience in household wiring or by a 

qualified electrician. The electrical system, and the method of electrically connecting 

the fixture to it, must be in accordance with the National Electrical Code and local 

building codes.

•  Do not allow sensor head to touch light housing – maintain at least 

1 in. space between fixture and sensor.

•  Keep away from flammable objects. Do not position fixture within 2 in.

of any combustible materials.

•  MINIMUM 90°C SUPPLY CONDUCTORS.
•  For proper operation and protection against damage, the motion sensor head 

adjustment knobs must be facing the ground.

•  This device complies with Part 15 of the FCC Rules. Operation is subject to the 

following two conditions: (1) This device may not cause harmful interference, and (2) 

this device must accept any interference received, including interference that may cause 

undesired operation. Under Part 15   of the FCC Rules, any changes or modifications to 

the motion detector described in this instruction sheet that are not expressly approved 

by Eaton could void the user’s authority to operate the equipment.

   NOTE:

 This equipment has been tested and found to comply with the limits for  

 

  a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are  

 

  designed to provide reasonable protection against harmful interference in a  

 

  residential installation. This equipment generates, uses and can radiate radio  

 

  frequency energy and if not installed and used in accordance with the instructions,  

 

  may cause harmful interference to radio communications. However, there is no  

 

  guarantee that interference will not occur in a particular installation. If this  

 

  equipment does cause harmful interference to radio or television reception, which  

 

  can be determined by turning the equipment off and on, the user is encouraged to  

 

  try to correct the interference by one or more of the following measures:

       - Reorient or relocate the receiving antenna.

       - Increase the separation between the equipment and receiver.

       - Connect the equipment into an outlet on a circuit different from that to which the  

         receiver is connected.

       - Consult the dealer or an experienced radio/TV technician for help.
        

 

WARNING: FCC Regulations state that any unauthorized changes or 

         modifications to this equipment not expressly approved by the manufacturer  

         could void the user’s authorization to operate this equipment.
SAVE THESE INSTRUCTIONS.

FOR BEST RESULTS

•  Install the motion sensor/transmitter 8-12 feet 

  above the ground. (Motion sensor is less sensitive 

  above 12 feet.)
•  Locate motion sensor so motion moves across 

  detection zone (Fig. 1).
•  Locate sensor away from heat producing sources to

ITEMS REQUIRED

 

(Purchase separately)

•  Phillips screwdriver
•  Outdoor weatherproof silicone caulking
•  (2) 100 watt (MAX) PAR 38 floodlight bulbs

NOTE:

 This fixture was designed to work with up to 150 watt maximum PAR halogen flood 

bulbs. For improved energy efficiency, lower wattage PAR halogen flood bulbs may be used. 

Compact Fluorescent (CFL) bulbs contain electronics which may interfere with the motion 

sensing function of your fixture and are not recommended. To meet ENERGY STAR

®    

requirements, maximum lamp wattage can not exceed 250 watts.

HOW IT WORKS

Your motion activated floodlight senses heat images from 

objects such as people, large animals and automobile engines. 

When motion is detected, the lights will automatically turn 

on. Once motion has stopped, the lights will turn off after a 

preselected time delay. Your motion activated floodlight may 

also be used as a standard floodlight.

IMPORTANT SAFETY INSTRUCTIONS

  When using product, basic precautions should always be followed, including the following:

•  Heed all warnings, including below warnings AND those included on product.
•  Save these instructions and warnings.
•  For outdoor use only.
•  cULus LISTED for wet location.
•  Disassembly of your fixture will void the warranty.
•  Your fixture is prewired and preassembled for easy installation.

•  Read and follow these instructions.
•  To reduce the risk of a burn during relamping, disconnect power supply to the unit 

before relamping.

•  Bulb gets HOT quickly! 
•  Always replace bulb with the same wattage or lower wattage than marked. Installing 

a bulb of a higher wattage could create a fire hazard. Use of a higher wattage bulb  

will void the warranty (maximum 150 watt halogen bulb). 

CAUTION

•  Connect fixture to a 120 volt, 60 Hz power source. Any other connection voids 

the warranty.

•  Mount fixture to a grounded, recessed-mounted standard junction box marked for use 

MS245R (Bronze)

 ENGLISH

Up to 

70 feet

270 degrees

1

WARNING

A.

  Motion detector 

  and light fixture
  Detector de movimiento 

  y accesorio
  Luminaire avec détecteur de 
 mouvement

B.

  (2) Lampholder gaskets

  (2) Juntas obturadoras 

   del receptáculo
   (2) Joints statiques de douille

D.

  (2) #6 and (2) #8 mounting screws 

   (use the size that fits your junction box)
   (2) Tornillos #6 y (2) tornillos #8 de montaje (utilice el  

   tamaño que mejor se adecue a su caja de conexión) 
  

(2)  vis nº 6 et (2 )vis nº 8 pour boîte de jonction (choisissez  

   la dimension convenant à votre boîte de jonction) 

C.

   (3) Wire nuts

   (3) Conectores del cables 
  

(3) Capuchons de connexion

E.

  (2) Reflectors

   (2) Reflectores
   (2) réflecteurs

MS245RW (White)

Summary of Contents for All-Pro MS245RW

Page 1: ...ser s authorization to operate this equipment SAVE THESE INSTRUCTIONS FOR BEST RESULTS Install the motion sensor transmitter 8 12 feet above the ground Motion sensor is less sensitive above 12 feet Lo...

Page 2: ...Set dial to desired time setting The higher the time setting the longer the lamps will be ON Maximum time is 12 minutes SELECTING YOUR DESIRED FEATURE TROUBLESHOOTING E A 4 6 Round 1 1 2 in Octagonal...

Page 3: ...d montage du luminaire annule la garantie Le luminaire est c bl et assembl pour faciliter son installation Lisez et suivez ces instructions Mettez l alimentation lectrique du luminaire hors tension av...

Page 4: ...ol 4 Marchez dans la zone de d tection jusqu o vous souhaitez que les mouvements soient d tect s 5 R glez l angle du d tecteur jusqu l obtention des r sultats souhait s REMARQUE Pour une port e maxima...

Page 5: ...TOUTEFOIS S Y LIMITER TOUTE GARANTIE DE QUALIT MARCHANDE ET POUR UN USAGE PARTICULIER Eaton garantit ses clients pendant une p riode de trois ans compter de la date d achat que ses produits Eaton sont...

Page 6: ...l sensor lejos de objetos m viles como por ejemplo rboles arbustos grandes y tr fico callejero MONTAJE Y CABLEADO DEL ACCESORIO ADVERTENCIA Riesgo de choque el ctrico Antes de la instalaci n o reparac...

Page 7: ...S ACCIDENTALES O RESULTANTES SIN IMPORTAR LA ACCI N LEGAL YA SEA POR CONTRATO RESPONSABILIDAD ESTRICTA O DE FORMA EXTRACONTRACTUAL INCLUYENDO LA NEGLIGENCIA NI POR TAMPOCO DE LA P RDIDA DE GANANCIAS E...

Reviews: