background image

 

IOM 570 06/2011

  

                                          REV A. 

 

Page 6 of 8 

E

aton Hydraulics LLC, Filtration Division, 44 Apple Street, Tinton Falls, NJ 07724, www.eaton.com/filtration, Phone 732-212-4700

 

Installation, Operation & Maintenance Manual 

Model 570 Duplex Basket Strainer

 

 

 

Summary of Contents for 570

Page 1: ...N A duplex strainer is a device installed in a pipeline to remove dirt and other unwanted debris from fluids Straining is accomplished by directing the fluid through sized openings in a basket Duplex strainers are installed where fluid flow cannot be interrupted while the basket is removed for cleaning Duplex strainers are designed to withstand the rated pressure of the piping system For additiona...

Page 2: ...ft eye is used to lift ONLY the cover 1 Position the strainer in the line so that the fluid enters the connection marked inlet and be sure sufficient headroom is provided for easy removal of cover and baskets 2 Support the strainer in the line as follows Using the bosses on the bottom of the strainer place the unit on concrete or steel pads DO NOT support the strainer or the piping coming to and f...

Page 3: ... pressure equalizer valve 4 Slowly introduce fluid to be strained CAUTION Start system GRADUALLY This eliminates sudden shock to strainer and other equipment in the line CAUTION Recheck Operation procedure to ensure that both valve discs are sealing the same chamber There should be NO SIGNIFICANT AMOUNT OF FLOW from vent in chamber that is isolated NOTE The valve discs or gates are not designed or...

Page 4: ...d drain fluid through bottom drain to a lever below the basket seat 4 Remove dirty baskets and clean or exchange them BASKET REPLACEMENT 1 Place new or clean basket squarely on basket seat 2 Be sure basket handle is sufficiently high to be compressed by body cover 3 Inspect body cover gasket and seal surface clean seat or replace gasket as necessary Always keep spare body cover gaskets in stock 4 ...

Page 5: ... after inlet and outlet pipeline valves are closed both cover vents are open and there is no flow of air or fluid through the vents Location of Leak Correction Spindle mounting header joint Replace spindle mounting 0 ring and or spindle mounting gasket Spindle mounting sight holes Replace O ring on O ring nut Excessive leakage past the valve discs Replace valve seat Repair or replace valve disc HO...

Page 6: ... REV A Page 6 of 8 Eaton Hydraulics LLC Filtration Division 44 Apple Street Tinton Falls NJ 07724 www eaton com filtration Phone 732 212 4700 Installation Operation Maintenance Manual Model 570 Duplex Basket Strainer ...

Page 7: ...ion 2 Short Basket 2 Long Basket 2 Header Cover Gasket 3 Body Cover Gasket 8 O ring 4 O ring Spindle Mounting 2 Snap Ring 2 Basket Flange Gasket Mesh lined baskets only When ordering spare parts be sure to specify all nameplate data as well as description and quantity of parts Always use genuine Eaton replacement parts for guaranteed fit and performance Visit our web site www eaton com filtration ...

Page 8: ... 49 2486 809 0 Fax 49 2486 809 800 Eaton China No 3 Lane 280 Linhong Road Changning District 200335 Shanghai P R China Voice 86 21 5200 0099 Fax 86 21 5200 0400 WARRANTY All products manufactured by Seller are warranted against defects in material and workmanship under normal use and service for which such products were designed for a period of eighteen 18 months after shipment from our factory or...

Reviews: