5

6KG

L≤15m

12KG

L≤20m

9KG

L≤15m

18KG

L≤20m

Fig 8 and Fig 9 are the installation diagram

Fig 8

Fig 9

Tips:

in the place where there is no need to install pipes, try not to fog along the front

of the machine (the direction of the control panel), fog to the left, right or behind of
the machine. Please ensure each outlet of the fog with a length of no less than 1 meter
pipe extension(you can also increase a 45℃ elbow). Under the condition of no
pipeline, it is not allowed to be used for a long time, otherwise the equipment will be
easily damaged by the dripping of fog droplets and the short cycle of moisture will
lead to the failure of components. The worst result is cause accidents. It is
recommended that the equipment be separated from the humidifying room where the
humidity is higher than 85%RH.

5. Atomizing system

The indicator light is green when powered up

and is red when working. The

indicator light is green when the water is not enough or water lever is not reached.

Requirements for water quality: when the water temperature of the tank is
≥45℃,the atomizer is forced to start protection, not to run; when there is oily or
sticky substances in the water, the atomizer does not work or fog; when the water

Summary of Contents for EW-030HDA

Page 1: ... Configuration and technical parameters 2 3 Filter installation and cleaning 3 4 Installation instruction 3 5 Atomization system 5 6 Regular failure and failure elimination 7 7 Maintenance 9 8 Precautions 9 9 After sales service 10 Please read this carefully before using and keep it for reference Easywell Electronic Co Ltd ...

Page 2: ...o harm to human and animal through the high frequency resonance of ceramic chip it will make the water leaving the cover to create the water mist shape no need to heat or chemical to produce 1 to 5 um water particles floating in the air thereby to improve the air quality and improve the environment 2 Configuration and technical parameters Model EW 030HDA Mist capacity 30 L hour ...

Page 3: ...stem of the equipment more effectively and prevent the entry of impurities to affect the atomization system please install the water filter and ensure that every interface with no waster leakage and air leakage Clean the filter element according to the local actual water conditions generally 1 2 months or so to clean the filter element impurities or replacement Turn on the water filter bottle take...

Page 4: ...located in the position of the PVC pipe cross section level up 30 degrees or so the best diameter of the out put fog hole are 20 to 30mm the spacing between the outlet hole of the fog is depends on the length of the pipe for example if the single pipe length is 12m the spacing should be with 15 20cm Please also block off the end of the pipe so as to avoid water accumulation in the pipeline the lev...

Page 5: ...otherwise the equipment will be easily damaged by the dripping of fog droplets and the short cycle of moisture will lead to the failure of components The worst result is cause accidents It is recommended that the equipment be separated from the humidifying room where the humidity is higher than 85 RH 5 Atomizing system The indicator light is green when powered up and is red when working The indica...

Page 6: ...ace a new atomizer or atomized ceramic wafers energy exchange wafers The replacing method of atomizing plate is as follow see fig 11 图 11 Fig 11 Operation as following a Cut off the power drain the water from the tank and dry the water on the surface of the atomizer b Unscrew the pressure ring with the lock piece remove the old atomizer chip and keep the atomizer chamber clean c When install the n...

Page 7: ...cuit b Remove the foreign matter in the float c The pressure must reach 5KG Don t stop when adding water a The water float is displaced b There is foreign matter in the float c The float is damaged a Adjust it to the correct position b Remove the foreign matter c Replace the float No fog outlet a The voltage 5 lower than the standard b The water is too hard c Too dirty in the tank a Check the powe...

Page 8: ...r 2 Water tank cleaning clean the water tank regularly Turn off and uplog the machine before cleaning so as to avoid contact incident 3 Cleaning method Turn the fixing screw on the cover of the water tank and open the tank cover plate please pay attention to the circuit connection inside use a soft cotton close or brush to clean Dish soap is available see Fig 12 The scale and other foreign matter ...

Page 9: ...in out the water if the machine is out of working for long time 8 Please don t dig hole on the cover of the machine directly when install the water filter 9 The power supply must be cut off if the machine stop working over 48 hours and the water storage in the tank must be drained out entirely As if the storage water stocked too long time it will become ropy this will affect the function of the eq...

Page 10: ...e equipment We give 1 year warranty for the whole machine in the warranty period as a result of the failure problem of the product quality our after sales will give free maintenance The artificial damage and the damage caused by the irresistible force are not covered in the warranty We will charge a trend in the maintenance if the machine is not be operated correctly Please use clean water If the ...