1. TECHNICAL DATA
EASYWAY 110
Power supply voltage
Vac
230 50/60Hz
Main power supply 230 Vac
W
230
Input current to the 230 Vac line
A
1
Motor type
Vdc
24
Max. motor power
W
180
Max. motor current
A
6
Thrust
N
300
Max. initial torque
Nm
15
Continuous work time
Minutes
20
Max. gate weight
Kg
400
Lubrication
Type
Permanent lubricant
Limit switches
Type
Magnetic - Hall effect switch
Acoustic pressure level
dB
LpA-70
Protection class
IP
55
Operating temperature
°C
From -20 to +70
Motor dimensions
mm
335 X 170 H 300
Weight
Kg
7
1.1 Limitations of use
The motoreducer installation area needs to provide space required for conducting maintenance and
manual release.
27