E8 D1 Manual
5 of 9
SINGLE Gate Operation:
1.
DIP
switch
5
set to
ON
position and connect
motor wires to “MT A”
2.
Parallel the receiver output for 1 side and 2 side
and wire into D1
block 7 terminal 3 (single open). Receiver Common is wired to block 7
terminal 2 (COM).
Note:
Do NOT have connection on block 7 terminal 2 (dual open) as this
will confuse the board and Motor B will not cut off.
3. Set the ARM in the CLOSE position and then power up the board.
4. Press the remote transmitter and observe GREEN Led indicating
Opening cycle on D1 board. Gate is running on Slow Speed. If it is
RED then switch OFF power and reverse the motor wire polarity to
change the direction of the motor. Return to step 3.
5. Board auto cutoff when high amp. GREEN Led will go off.
6. Press transmitter again. Gate should close. Observe the RED Led
indicating Closing cycle
7. In the 1 Arm operation, gate when fully closed (at high speed) the first
time, may reopen. This is ok.
8. Press the Transmitter again. Observe the RED Led indicating closing
cycle.
9. When the gate is stopped, the RED Led will go off.
12Vdc power only used:
When the system is running on battery only (in the
event of AC failure), the arms will open simultaneously but closes sequentially
i.e. 1 x arm starts after the other finishes. This ensures that the battery will be
loaded on only 1 arm at any one time. The cycle will be 20-30% slower then if
powered with transformer.
External auto-close switch:
The switch installed at the bottom of the control
panel is hard wired as
30 sec Auto Close
only. You must place 7 and 8 to
OFF to use the switch. There are 3 x male connectors on the back of the
switch under the control board. Line up the
“0” on the switch to its adjacent
male connector and connect the red female (black wire) tab from the control
board. Use the middle male connector with the second red female tab.
“0” means the 30 sec auto close is OFF
“1” means the 30 sec auto close is ON
Optional 12V devices:
One number of 12Vdc Output (parallel to the Battery),
protected with a 1 Amp in-line fuse has been pre-wired in your control panel.
Connect the Positive (+12V) of the optional device to the wire connector with
the red cable and the (Com) to the connector with the black cable.
Keypad Output to Open the Gate:
Connect keypad to block 7 on the control
board with keypad signal to 1 (2 arrows) and keypad common to terminal 2 (2
arrows). This will activate both arms on double swing setup. If double gate
setup and you want
only 1 gate
to open (pedestrian access) connect signal to
terminal 3.