Battery:

 Your system is supplied with a 12V 7AH Lead Acid Maintenance 

Free Battery and a Z-Shape steel mounting bracket with screw. With the 
battery terminals at the bottom facing the center, position battery in the right 
bottom of your control board. There are 2 plastic locating pegs molded into the 
control board box. You MUST mount battery upside down so as the steel 
mounting bracket, when installed does not contact between the battery power 
terminals.  

230vac-18vac Transformer:

 Transformer can be relocated to around 100m 

from control box using a transformer kit (in a protective electrical box with 
mains lead and plug) or positioned inside the control box if mains power is 
available at the gate.

 

In either option you 

MUST

 install transformer via a RCD 

to avoid injury from shock as per local government electrical requirements. 
Always switch off mains power when any works is being carried out on or 
around gate installation. We recommend a minimum 1.5mm x 2 core direct 
burial garden lighting cable up to 50m and a larger 2.5 to 4 mm cable is 
commonly used to around 100m. Connect mains power supply to the 2 x 
orange wires (230Vac) at the transformer. Connect 2 x white wires (16Vac) to 
control board block 1 (AC input). As the input is AC, the polarity of the cables 
need not be observed. Disregard the purple and black wires (if fitted) as these 
are for our 24VAC sliding gate control board D2 only. Protect the wire ends so 
as not to make contact with the transformer. 

DIP SWITCH setting on the control board: 

[1] 

ON 

 

= Delay

 

Close motor A (MT A) for 2 seconds after MT B 

 

 

 

 

- used in conjunction with solenoid lock 

[1] 

OFF 

 

= Gate(s) open/close at same time 

[2] 

ON 

 

= Small Reverse before opening used with 12V lock 

[2] 

OFF 

 

= Gates open immediately without small reverse  

 

 

movement 

[3]

 OFF

 

&

 [4] 

OFF  = Light ON (gate open) & cut off 1 min. after gate closed               

[5] 

ON 

 

Single Gate Operation 

(MT A) for external Push  

 

 

 

 

Switch 

[6] 

OFF 

 

= Not in use 

[7] 

OFF &

 [8] 

OFF

  

=

 

Disable Auto Close 

 

 

[7] 

OFF &

 [8] 

ON   = 030 sec. Auto Close (Pre-wired to External Switch)

 

[7] 

ON & 

[8] 

OFF   = 060 sec. Auto Close 

 

[7] 

ON &

 [8] 

ON  

= 120 sec. Auto Close 

Solar Power:

 The system can be solar powered via an optional solar systems 

voltage regulator connected directly to the battery. The 12Vdc 7Ah (amp-hour) 
battery supplied may not be suitable for heavy gates or frequent use. Add 
another 7Ah battery (in Parallel) giving a total of 14Ah. You can install this in 
the lid of the control box using the locating pegs.  

Summary of Contents for D1

Page 1: ...gate operates in proper order and is kept dry and insect free Mount the Control box as close to the motor s maximum 10m cable as possible connected with minimum 1 5mm 2 core electrical cable to reduce any voltage drop which will affect the performance of the system 2 5mm to 4mm house cable is commonly used 1 Make sure all wiring works are correct and in good condition before supplying the mains po...

Page 2: ...mains power supply to the 2 x orange wires 230Vac at the transformer Connect 2 x white wires 16Vac to control board block 1 AC input As the input is AC the polarity of the cables need not be observed Disregard the purple and black wires if fitted as these are for our 24VAC sliding gate control board D2 only Protect the wire ends so as not to make contact with the transformer DIP SWITCH setting on ...

Page 3: ...le and bottom so care must be taken when setting each DIP switch Match the new remote DIP settings to the working current remote DIP switch positions Check the signal transmission by pressing your new remote Changing Remote Codes Positioned inside your gate opener control box is the remote Receiver box with 5 wires connecting to your control board Open this up to view the code DIP switches which i...

Page 4: ...n low speed until gate s are fully opened Check that the LED lights at block 2 are green If red LED is observed disconnect power then reverse arm wire in question and start setup again from step 1 4 Both the motor will stop automatically when the gate is hard stopped High current cut off by the circuit board is automatically achieved 5 Press remote transmitter again and let the motor close high sp...

Page 5: ...ilure the arms will open simultaneously but closes sequentially i e 1 x arm starts after the other finishes This ensures that the battery will be loaded on only 1 arm at any one time The cycle will be 20 30 slower then if powered with transformer External auto close switch The switch installed at the bottom of the control panel is hard wired as 30 sec Auto Close only You must place 7 and 8 to OFF ...

Page 6: ... from being forced open when fully closed Connect to lock at block 3 DIP switch 2 is placed to ON to allow lock tongue to release freely a second before gate performs an open cycle Loop Detector Free Exit Function Connect the Loop Detector signal cables to Block 6 In the Free Exit Mode a command via the loop detector or underground motion sensor will cause the gate the open If another command is m...

Page 7: ...to the fact that the Lamp Photocell is exposed to significant lighting When connected to Pillar Lights this design prevents the Pillar Light from turning ON during the Day If you wish that the Pillar Lights be turned on irrespective of the ambient lighting use a Dark Tape to cover the Lamp Photocell or turn the Photocell inwards when mounted in the Control Box Lamp Relay Activated when Lamp Photoc...

Page 8: ...setup obstructions Problem The gate does not fully open and close or stops half way Ensure there is no obstruction to the movement of the gate This could also be high resistance such as poor gate installation or high winds activating the anti obstruction sensing This can be verified by releasing the gate to Emergency release mode Manual push the gate open and close to detect any obstruction Ensure...

Page 9: ...FUSE Connect Keypad and Solar Regulator observe Polarity 12 Vdc Relay To Activate 1 Gate To Activate 2 Gate AC Transformer MT B IR BEAM MT A LOCK LAMP RELAY NC P SW 1 2 For Single Arm Use only MOTOR A and Set DIP 5 to ON Loop Detector IR Beam LIGHT SENSOR EASYSYSTEMS D1 SWING GATE CONTROL BOARD version 1 3 0 Warning Insure you have sealed all means of entry to the control box by insects and water ...

Reviews: