Easysystems D1 Manual Download Page 4

E8 D1 Manual 
 

4 of 9 

of the system. Use a suitable electrical junction box to protect cable joints 
from moisture damage.  

Check Motor Rotation Direction: 

After power supply has been connected to 

the Control Panel, make sure the gate swings in the correct direction. The 
system will initiate an OPEN signal (green LED on board) the first time the 
remote is pressed. The second time the remote is pressed the system initiates 
a CLOSE function (red LED on board). Both gates should either OPEN or 
CLOSE in tandem.  

This is important as wrong direction will cause the system work in the reverse 
manner. 

Hint:

 Check the LED lights above Block 2. Green indicates an OPEN cycle 

and Red a CLOSING cycle. To reverse the direction of the motor, reverse the 
wire polarity at the Control Panel. 

Setting the System: 

Double Gate Operation 

1.  Unplug AC power 

and

 Battery (or solar positive wire if fitted) and make 

sure the gate(s) are 

completely CLOSED

.

 

2.  After 30 seconds reconnect power to the system until short clicking 

from board can be heard.

 

3.  Press remote transmitter for gate(s). Let the motor open (low speed) 

until gate(s) are fully opened. Check that the LED lights at block 2 are

 

green

. If red LED is observed, disconnect power then reverse arm wire 

in question and start setup again from step 1.

 

4.  Both the motor will stop automatically when the gate is hard stopped. 

High current cut-off by the circuit board is automatically achieved.

 

5.  Press remote transmitter again and let the motor close (high speed) 

until both gates are fully closed. LED lights at block 2 are

 Red

.

 

Both the 

motor will stop automatically when the gate is hard stopped. High 
current cut-off by the circuit board is automatically achieved.

 

The system has now stored the range between opening and closing time. 
The microprocessor will automatically adjust the low speed and high speed 
opening / closing of the system.  

Setup is now complete.

 

6.  Test each cycle a few times to make sure the microprocessor has 

stored the correct range.

 

Note that :

 

7.  The gate will auto reverse when the system detects obstruction (high 

amp) during closing operation.

 

8.  The gate will stop when the system detects obstruction (high amp) 

during opening operation.

 

To Reset :

 

9.  To 

RESET 

the Memory, remove all power sources (Mains and Battery). 

Wait for 30 seconds. System will reset the open / close calibration. 
Repeat Step #1 

– 5 to set the memory.

 

Summary of Contents for D1

Page 1: ...gate operates in proper order and is kept dry and insect free Mount the Control box as close to the motor s maximum 10m cable as possible connected with minimum 1 5mm 2 core electrical cable to reduce any voltage drop which will affect the performance of the system 2 5mm to 4mm house cable is commonly used 1 Make sure all wiring works are correct and in good condition before supplying the mains po...

Page 2: ...mains power supply to the 2 x orange wires 230Vac at the transformer Connect 2 x white wires 16Vac to control board block 1 AC input As the input is AC the polarity of the cables need not be observed Disregard the purple and black wires if fitted as these are for our 24VAC sliding gate control board D2 only Protect the wire ends so as not to make contact with the transformer DIP SWITCH setting on ...

Page 3: ...le and bottom so care must be taken when setting each DIP switch Match the new remote DIP settings to the working current remote DIP switch positions Check the signal transmission by pressing your new remote Changing Remote Codes Positioned inside your gate opener control box is the remote Receiver box with 5 wires connecting to your control board Open this up to view the code DIP switches which i...

Page 4: ...n low speed until gate s are fully opened Check that the LED lights at block 2 are green If red LED is observed disconnect power then reverse arm wire in question and start setup again from step 1 4 Both the motor will stop automatically when the gate is hard stopped High current cut off by the circuit board is automatically achieved 5 Press remote transmitter again and let the motor close high sp...

Page 5: ...ilure the arms will open simultaneously but closes sequentially i e 1 x arm starts after the other finishes This ensures that the battery will be loaded on only 1 arm at any one time The cycle will be 20 30 slower then if powered with transformer External auto close switch The switch installed at the bottom of the control panel is hard wired as 30 sec Auto Close only You must place 7 and 8 to OFF ...

Page 6: ... from being forced open when fully closed Connect to lock at block 3 DIP switch 2 is placed to ON to allow lock tongue to release freely a second before gate performs an open cycle Loop Detector Free Exit Function Connect the Loop Detector signal cables to Block 6 In the Free Exit Mode a command via the loop detector or underground motion sensor will cause the gate the open If another command is m...

Page 7: ...to the fact that the Lamp Photocell is exposed to significant lighting When connected to Pillar Lights this design prevents the Pillar Light from turning ON during the Day If you wish that the Pillar Lights be turned on irrespective of the ambient lighting use a Dark Tape to cover the Lamp Photocell or turn the Photocell inwards when mounted in the Control Box Lamp Relay Activated when Lamp Photoc...

Page 8: ...setup obstructions Problem The gate does not fully open and close or stops half way Ensure there is no obstruction to the movement of the gate This could also be high resistance such as poor gate installation or high winds activating the anti obstruction sensing This can be verified by releasing the gate to Emergency release mode Manual push the gate open and close to detect any obstruction Ensure...

Page 9: ...FUSE Connect Keypad and Solar Regulator observe Polarity 12 Vdc Relay To Activate 1 Gate To Activate 2 Gate AC Transformer MT B IR BEAM MT A LOCK LAMP RELAY NC P SW 1 2 For Single Arm Use only MOTOR A and Set DIP 5 to ON Loop Detector IR Beam LIGHT SENSOR EASYSYSTEMS D1 SWING GATE CONTROL BOARD version 1 3 0 Warning Insure you have sealed all means of entry to the control box by insects and water ...

Reviews: