E8 D1 Manual
4 of 9
of the system. Use a suitable electrical junction box to protect cable joints
from moisture damage.
Check Motor Rotation Direction:
After power supply has been connected to
the Control Panel, make sure the gate swings in the correct direction. The
system will initiate an OPEN signal (green LED on board) the first time the
remote is pressed. The second time the remote is pressed the system initiates
a CLOSE function (red LED on board). Both gates should either OPEN or
CLOSE in tandem.
This is important as wrong direction will cause the system work in the reverse
manner.
Hint:
Check the LED lights above Block 2. Green indicates an OPEN cycle
and Red a CLOSING cycle. To reverse the direction of the motor, reverse the
wire polarity at the Control Panel.
Setting the System:
Double Gate Operation
1. Unplug AC power
and
Battery (or solar positive wire if fitted) and make
sure the gate(s) are
completely CLOSED
.
2. After 30 seconds reconnect power to the system until short clicking
from board can be heard.
3. Press remote transmitter for gate(s). Let the motor open (low speed)
until gate(s) are fully opened. Check that the LED lights at block 2 are
green
. If red LED is observed, disconnect power then reverse arm wire
in question and start setup again from step 1.
4. Both the motor will stop automatically when the gate is hard stopped.
High current cut-off by the circuit board is automatically achieved.
5. Press remote transmitter again and let the motor close (high speed)
until both gates are fully closed. LED lights at block 2 are
Red
.
Both the
motor will stop automatically when the gate is hard stopped. High
current cut-off by the circuit board is automatically achieved.
The system has now stored the range between opening and closing time.
The microprocessor will automatically adjust the low speed and high speed
opening / closing of the system.
Setup is now complete.
6. Test each cycle a few times to make sure the microprocessor has
stored the correct range.
Note that :
7. The gate will auto reverse when the system detects obstruction (high
amp) during closing operation.
8. The gate will stop when the system detects obstruction (high amp)
during opening operation.
To Reset :
9. To
RESET
the Memory, remove all power sources (Mains and Battery).
Wait for 30 seconds. System will reset the open / close calibration.
Repeat Step #1
– 5 to set the memory.