background image

EasyIO FT Series – User Reference v1.0 

 

Disclaimer 
 

Confidentiality Notice 

The information contained in this document is confidential information of EasyIO Holdings Pte Ltd. Such 
information and the software described herein, is furnished under a license agreement and may be used 
only in accordance with that agreement. 
The  information  contained  in  this  document  is  provided  solely  for  use  by  EasyIO  Holdings  Pte  Ltd 
employees, licensees, and system owners; and, except as permitted under the below copyright notice, is 
not to be released to, or reproduced for, anyone else. 
While every effort has been made to assure the accuracy of this document, EasyIO Holdings Pte Ltd is not 
responsible  for  damages  of  any  kind,  including  without  limitation  consequential  damages,  arising  from 
the  application  of  the  information  contained  herein.  Information  and  specifications  published  here  are 
current as of the date of this publication and are subject to change without notice. The latest product 
specifications can be found by contacting our corporate headquarters  or support channel.  
 

Trademark Notice 

 
EasyIO logo are registered trademarks of EasyIO Holdings Pte Ltd. 
 
CPT Tool is by Online Tools Inc. 
 
BACnet and ASHRAE are registered trademarks of American Society of Heating, Refrigerating and Air- 
Conditioning Engineers. All other product names and services, mentioned in this publication, that are 
known to be trademarks, registered trademarks, or service marks are the property of their respective 
owners. 
 

Copyright and Patent Notice 

This document may not, in whole or in part, be copied, photocopied, reproduced, translated, or reduced 
to any electronic medium or machine-readable form without prior written consent from EasyIO Holdings 
Pte Ltd 
 
Copyright © 2018 EasyIO Holdings Pte Ltd. All rights reserved 
 

Disclaimer 

The material in this manual is for information purposes only. The contents and the product it 
describes are subject to change without notice. EasyIO Holdings Pte Ltd makes no 
representations or warranties with respect to this manual. In no event shall EasyIO Holdings Pte Ltd be 
liable for any damages, direct or incidental, arising out of or related to the use of this manual. 
 

EasyIO Holdings Pte Ltd

 

101, Cecil Street #09-07 
Tong Eng Building 
Singapore 069533 
  

[email protected]

  

 

 

Summary of Contents for FT Series

Page 1: ...EasyIO FT Series User Reference v1 0 1 EasyIO FT Series User Reference...

Page 2: ...EasyIO FT Series User Reference v1 0 2 Document Change Log 16th Jan 2018 Document created...

Page 3: ...e headquarters or support channel Trademark Notice EasyIO logo are registered trademarks of EasyIO Holdings Pte Ltd CPT Tool is by Online Tools Inc BACnet and ASHRAE are registered trademarks of Ameri...

Page 4: ...receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the deale...

Page 5: ...umpers Configurations 8 Wiring diagram 9 Digital Output Wiring Connection 10 Analog Output Connection 11 Universal Input Connection 12 Network and Wireless 13 Login Details 14 Establish a connection f...

Page 6: ...ight freeRTOS V8 2 0 OS for premium performance Supports BACnet IP server over Wi Fi and TCom or premium performance with Niagara AX and N4 The Build in boot loader can be carried out remotely No more...

Page 7: ...ividual power supply for each controller If a single power supply is used to power up multiple EasyIO FW series make sure controller power supplies are connected with the same polarity Electrical Powe...

Page 8: ...ptions Options are referring to IO Input Output configurations FW Model UI AO DO EIA 485 Protocol Supported FT 04B 2 1 Voltage Only 1 1 Sedona BACnet IP server Jumpers Configurations Below image shows...

Page 9: ...EasyIO FT Series User Reference v1 0 9 Wiring diagram Below diagram shows the general wiring diagram for FT series according to its model...

Page 10: ...or general purpose isolated digital output connections relay output Pilot Duty rating is as below Pilot Duty 24 VAC 2 0A 24 VDC 2 0A Digital Output 1 2 Channels Type Relay Contacts SPST NO 48VA at 24V...

Page 11: ...g Output Connection EasyIO FT series has Analog Output connections Each Analog Output can only drive voltage The working range for voltage is 0 10V Universal Output 1 2 Channels Type Voltage 0 10VDC M...

Page 12: ...ternal register settings Universal Input 2 Channel Resistance 3K 50K 10 Ohm Thermistor 10K Type 3 10K Type 2 20K All 0 1 Deg C UI as Digital Input Voltage Free Contact a Resistance The working range o...

Page 13: ...the FT controller Access Point SSID FT xxxxxx where xxxxxx is the last 6 digit of the MAC address Mac Address label located at the bottom casing of each FT series controller The MAC address label is a...

Page 14: ...enable It has DHCP server enable The best approach to connect to a brand new FT series controller is by utilizing its DHCP server and run automatic IP address in your device This reduces the hassle of...

Page 15: ...escription SSID Access Point SSID name By default each SSID is named according to its MAX address You can change the SSID name to your preference PWD Access Point SSID password By default it is 123456...

Page 16: ...ller using the above chapter Establish connection for the first time In this chapter we will guide you to connect the FT Series controller to a Wi Fi network Once this chapter is completed your FT ser...

Page 17: ...please make sure you manage to connect to the FT controller using the above chapter Establish connection for the first time In this chapter we will guide you to connect to a EasyIO FT Series controlle...

Page 18: ...Series Sedona programming environment Proceed to create your Sedona program installing additional kits and etc LED Indicator Colour Behaviour Description 1 Constantly Blinking at 1 Hz Device Running...

Reviews: