CABLE INSTALLATION
Install cable on pipe in the preferred/recommended
orientation(s), in either straight or spiral method ac-
cording to pipe heat requirements. Secure cable every
24" using 3/4" w. fiberglass tape, NST-2 (or equiva-
lent).
2 TSRP POWER CONNECTION KIT
Installation Instructions
CABLE TERMINATION
1. Terminate end of cable per end seal
directions, Page 4.
2. Mark pipe where stand-off will be
mounted and cut cable 10" beyond
mark.
3. Push heater cables through the bot-
tom opening of stand-off, allowing 6"
(152mm) tail to protrude from threaded
end.
4. Place stand-off on the pipe at 4 o’clock
or 8 o’clock position and fasten with
pipe clamps.
5. Slide the sealing grommet, beveled
end first, over the heater cable and
position inside stand-off throat.
6. Apply silicon around the heater cable
sufficient to fill all voids in sealing
grommet.
7. Slide the box adapter over heater cable
and tighten securely to stand-off.
8. Prepare heater cable for power
termination according to Cable
Stripping Procedure, Page 3.
9. Connect power in accordance
with Power Connection Procedure,
Page 5.
a
WARNING!
Do not place pipe clamps over
the heater cable.
CABLE CONTROL
The Easy Heat SR Cables for pipe tracing applications
can be controlled in several different ways. The sim-
plest control method is to connect power to the cable
at all times; the self regulating characteristic of the
cable will ensure that cable power is reduced if heat
is not required on the pipe. Alternately, a thermostat
can be used to control the cable and maintain the pipe
at an appropriate temperature. Contact Easy Heat for
additional information.
*ITEMS NOT INCLUDED IN KIT
*ITEMS NOT INCLUDED IN KIT
10”
(254mm)
*Fiberglass Tape
Stand-off
*Fiberglass Tape
Stand-off
Sealing Grommet
Box Adapter
Power Termination
Pipe Clamps
8 o’clock
4 o’clock