CABLE INSTALLATION

Install  cable  on  pipe  in  the  preferred/recommended 

orientation(s), in either straight or spiral method ac-

cording to pipe heat requirements. Secure cable every 

24"  using  3/4"  w.  fiberglass  tape,  NST-2  (or  equiva-

lent).

2     TSRP POWER CONNECTION KIT

 Installation Instructions

CABLE TERMINATION

1.  Terminate end of cable per end seal 

directions, Page 4.

2.  Mark  pipe  where  stand-off  will  be 

mounted  and  cut  cable  10"  beyond 

mark.

3.  Push  heater  cables  through  the  bot-

tom opening of stand-off, allowing 6" 

(152mm) tail to protrude from threaded 

end.

4.  Place stand-off on the pipe at 4 o’clock 

or 8 o’clock position and fasten with 

pipe clamps.

5.  Slide  the  sealing  grommet,  beveled 

end  first,  over  the  heater  cable  and 

position inside stand-off throat.

6.  Apply silicon around the heater cable 

sufficient  to  fill  all  voids  in  sealing 

grommet.

7.  Slide the box adapter over heater cable 

and tighten securely to stand-off.

8.  Prepare  heater  cable  for  power 

termination  according  to  Cable 

Stripping  Procedure, Page 3.

9.  Connect  power  in  accordance 

with  Power  Connection  Procedure,  

Page 5.

a

WARNING!

Do not place pipe clamps over 

the heater cable.

CABLE CONTROL

The Easy Heat SR Cables for pipe tracing applications 

can be controlled in several different ways. The sim-

plest control method is to connect power to the cable 

at  all  times;  the  self  regulating  characteristic  of  the 

cable will ensure that cable power is reduced if heat 

is not required on the pipe. Alternately, a thermostat 

can be used to control the cable and maintain the pipe 

at an appropriate temperature. Contact Easy Heat for 

additional information.