23.Vibration alarm(optional)
The vehicle default is without shock sensor and has no vibration alarm function. User can choose to equip
with shock sensor version.
Once the vehicle is equip with shock sensor and in arm status, any hit or force on the vehicle will trigger the
alarm and siren beeps 5 times, turn signal light flashes 5 times at the same time.
24.GPS tracker( optional)
The alarm is with GPS tracker output and can add a GPS tracker on it (only compatible with Easyguard GPS
tracker). User can track the vehicle via smartphone (only compatible with IOS & Android system smartphone)
or online tracking and more function via the smartphone. For more information about the GPS tracker, please
refer to the GPS user manual.
The alarm default setting is without GPS tracker, if user want to add one, please contact us.
25.Parameter time prolong setting
1.Enter parameter setting status:
In disarm status, close all car doors well, step on foot brake pedal, quick press lock button 5 times, siren
beeps 5 times at the same time, then the siren continue to beeps another 5 times, this means the system is
enter into parameter setting status.
2.Lock signal prolong setting
Do not step on foot brake pedal, press lock button once, siren beeps once, means lock signal prolong 1
second.
Do not step on foot brake pedal, press lock button twice, siren beeps twice, means lock signal prolong 2
seconds.
Do not step on foot brake pedal, press lock button 3 times, siren beeps 3 times, means lock signal prolong
3 seconds.
The rest can be done in the same manner
The device maximum support press lock button 8 times and siren beeps 8 times, means lock signal
prolong 8 seconds.
If press lock button more than 8 times, siren not beep and user need to follow with point 5 to exit the
parameter setting procedure.
3.Unlock signal prolong setting
Do not step on foot brake pedal, press unlock button once, siren beeps once, means unlock signal
prolong 1 second.
Do not step on foot brake pedal, press unlock button twice, siren beeps twice, means unlock signal prolong
2 seconds.
Do not step on foot brake pedal, press unlock button 3 times, siren beeps 3 times, means unlock signal
prolong 3 seconds.
The rest can be done in the same manner
The device maximum support press unlock button 8 times and siren beeps 8 times, means unlock signal
prolong 8 seconds.
If press unlock button more than 8 times, siren not beep and user need to follow with point 5 to exit the
parameter setting procedure.
5. Exit the parameter setting
Close the door well, step on foot brake pedal, quick press lock button on key fob 5 times, at the same time,
the horn beeps 5 times, then continue to beep another 5 times, this means the system save setting and exit
the parameter setting procedure.
Control module
Working Voltage: DC12V+/-2V
Static current: <20mA
Induction emit current: <45mA
Frequency: 433.92Mhz 125Khz
Technical Parameter:
Starting system
Working Voltage: DC12V+/-2V
ACC current: 30A
ON current: 30A
Starting current: 30A
Remote control
Working voltage: DC2-3.5V
Static current: <8uA
Battery specification: CR2032 Lithium battery
Working frequency: 433.92Mhz 125Khz
Code method: Rolling code (hopping code)
Touch password keypad:
Working voltage: DC5V
Working current: : <8mA
Static current: <10uA
4.Starting time( Cranking time) prolong setting
Do not step on foot brake, press start button on the remote control once, siren beeps twice, means starting
time is prolong 0.5 seconds and become 1.3 seconds( default starting time is 0.8 second)
Do not step on foot brake, press start button on the remote control twice, siren beeps 3 times, means starting
time is prolong 1 seconds and become 1.8 seconds
Do not step on foot brake, press start button on the remote control 3 times, siren beeps once, means starting
time is back to default starting time 0.8 second.
6. Back to factory default setting
In disarm status, close all doors well, step on foot brake pedal and quick press lock button on key fob for
10 times, siren beeps 10 times and continue to beep another 10 times. This means all prolong setting data is
change to factory default setting.
Important: No matter you want to do 1 prolong setting or more, you need to enter the parameter setting first,
and after you finish setting, please remember to exit the setting.
1.How to use password entry function to unlock car?
Please refer to a.use touch password to unlock the car door on page 38-39 in user manual.
2.How to revise password on the touch password key pad?
Please refer to c.password revision on page 39 in user manual.
-42-
©
EASYGUARD
Electronics
.
All
right reserved.
-41-
©
EASYGUARD
Electronics
.
All
right reserved.