Troubleshooting
11
2.
Hold the brush and stretch the belt until the brush can be slotted back
into the vacuum head housing. Rotate the brush to ensure free
movement of the belt. Replace the brush guard and tighten screws until
secure.
Troubleshooting
1.
Has the cleaner overheated?
Allow vacuum to cool and rest for 45 minutes
2.
Are the filters blocked?
See cleaning instructions on how to properly clean all filters
3.
Is there a working electricity supply to the vacuum?
Check with another electrical appliance or try another electrical
supply
4.
Is the hose or vacuum head blocked?
See “how to clear a blockage”
5.
Is the floor selector height set correctly?
See “floor care control selector”
6.
Is the brush rotating?
Check that the brush is rotating
WARNING! A thermal cutout switches off the cleaner to prevent
overheating if it is used when full or there is a blockage or dirty filters. If
this should happen, switch to OFF, unplug and troubleshoot. It will take
about 45 minutes for the cut out to automatically reset.