http://www.e2a.net
Easy2Access A/S Easy-809 EU G2 Fingerprint lock
6
1) Other PIN codes can be deleted s soon as one PIN code is done. If you want to quit, just
press any non-numeric button at the outside keypad.
2) The PIN codes for Administrator 01 and 02 are Administrator PIN codes. Neither of them
can be deleted individually, but they can be done by resetting the lock. Regarding how to
reset the lock, please contact the local dealer or the manufacturer.
Setting the Matching Mode
There are three choices for how the Polysecu
®
LP808 will verify enrolled users for
access to unlock the door:
•
1:N
…When this is chosen, all users enrolled at this lock will only need to
match their enrolled Fingerprint or PIN Code to successfully unlock the door.
•
1:1
…When this is chosen, all users enrolled at this lock must enter their User
ID, then verify their enrolled Fingerprint to successfully unlock the door.
•
PIN code & Fingerprint
…When this is chosen, all enrolled users at this lock
must enter their PIN codes, then verify their enrolled Fingerprints to
successfully unlock the door.
1.
1:N (one to many)
Enter
#3 (green LED flashes one time) + Administrator PIN code + #
(red LED flashes one
time
and green LED flashes three times)
+ 0
When the green LED turns on and one long beep is heard, the lock is on
1:N
opening mode. If the
red LED flashes three times, the setting fails.
2.
1:1 (one to one)
Enter
#3 (green LED flashes one time) + Administrator PIN code + #
(red LED flashes one
time
and green LED flashes three times)
+ 1
When the green LED turns on and one long beep is heard, the lock is on
1:1
unlocking mode. If
the red LED flashes three times, the setting fails.
3.
PIN code & Fingerprint
Enter
#3 (green LED flashes one time) + Administrator PIN code + #
(red LED flashes one
time
and green LED flashes three times)
+ 2
When the green LED turns on and one long beep is heard, the lock is on
PIN code & Fingerprint