ADJUSTMENTS AND REPLACEMENTS
Replacements
06DEC05
AR4366-1
Page
191 of 219
5
Remove:
•
4 SCREWS
•
MCPU/DIGITIZER BOARD
•
A3 MEMORY BOARD - keep
To Install:
1
Install the old A3 MEMORY BOARD on the new MCPU/DIGITIZER BOARD.
2
Reverse the steps in the removal procedure.
Postrequisites:
Caution
Dangerous Voltage
1
Energize the system.
Important
For systems with software version
≥
4.1,
you must have a “Session ID” for access to “Service
Functions” and “Diagnostics”. See SERVICE BULLETIN 843.
2
At the main menu, click:
•
[Service Functions]
•
[Diagnostics]
•
[Download to Circuit Boards]
•
[Download MCPU Application]
3
Wait for software to download.
4
Click:
•
[Shutdown]
•
[OK]