23
The timing of HANDLER is shown in the diagram below:
Each time the trigger signal goes low, all output signals will go high.
If the conditions for above U_H_Lim/Pass/D_L_ Lim are met, the
corresponding pin levels will go low. When the STOP signal is received,
all output signals will go high and return to the normal operation mode.
Pin
Description
1
Floating, not connected
2
Pin 2 is designed for sorting "U_H_Lim" signals, which occur when the level is active low
and the sorting signal will remain active until the next Start signal occurs;
3
Pin 3 is designed for sorting "Pass" signals, which occur when the level is active low and the
sorting signal will remain active until the next Start signal occurs;
4
Pin 4 is designed for sorting "D_L_ Lim" signals, which occur when the level is active low
and the sorting signal will remain active until the next Start signal occurs;
5
Floating, not connected
6
Pin 6, STOP, is designed for measuring STOP signals, with the measurement ceasing when the
level is active low;
7
Pin 7, START, is designed for remote start (triggering) of signals, and when the level is active
low, a single low level can only start the signal once;
8
Pin 8 is externally connected to power sources ranging from +12V — +24V
9
Pin 9 is externally connected to the ground