background image

6

 

 

 

 

 

EM

-

Ocean Water Softener

 

Connecting the Softener

 

Once you have completed the installation of the valves, set them as follows:  

 

You can now safely return the stop cock to the open position. Using the hoses provided (if you ordered 
our installation kit) connect the straight end of the hose having first inserted the washer provided to the 
softener inlet and outlet valves. 

 

Connect the angled end to the softener. The Softener inlets and outlets should be indicated either with 
the words inlet or outlet or with an embossed directional arrow on the Softener tails. Normally the       
Softener tails are in a configuration of three with the centre normally being the waste outlet. 

 

Waste Pipe Installation

 

Connect the waste pipe to the waste outlet on the Softener and run the hose to either an up stand or  
outside drain. A minimum air gap of 20mm must exist at the end of 
the drain line. Softened water will have no 
adverse effect on a  septic tank. Should you 
need to extend the drain hose this can be 
done by connecting to a 15mm copper tube 
for a maximum run of 8 meters with a      
minimum daytime pressure of 40 psi.

 

The drain pipe can run uphill to a maximum 
of 1 meter with a minimum water pressure of 
40 psi. 

 

Overflow Connection

 

The overflow connection is the white ½

” 

hose spigot on the rear or side of the cabinet. The  overflow 

must be run downhill through an outside wall without kinks or restrictions. It is recommended the overflow 
hose be visible when it exits the outside wall. 

 

Electrical connection 

 

Connect the transformer provided to a continuous electric supply with the power off. Plug the flying lead 
from the transformer into the electrical connection on the controller. Ensure the flying lead cannot get 
caught on the camshaft or any moving parts on the machine. 

 

Preparing the Softener to go into service

 

Put approximately 5 litres of water into the brine tank. You may also at this point put a quantity of salt into 
the tank. Do not allow the salt level in the brine tank to exceed the height of the overflow. The amount of 
salt used will depend on the type and model of Softener you have, the hardness of your water and the 
number of appliances/showers/baths taken in your property.  You should keep the salt level above the 
water level and check the salt level on a regular basis until a usage pattern has been established. 

 

• 

Softener Inlet and Outlet valve 

CLOSED

 

• 

Bypass valve 

OPEN

 

 

 

waste

 

Inlet and outlet 

(marked)

 

Softener tails image

 

 

Ensure that the drain hose is not kinked or obstructed in any way as this will lead to an 

overflow of the softener

.

 

Summary of Contents for EM-Ocean

Page 1: ...1 EM Ocean Water Softener Installation and Operating guide...

Page 2: ...eding with your installation INDEX Contents of your box page 2 What to expect from your water softener page 3 Before you start page 4 Typical water softener configuration page 5 Connecting the softene...

Page 3: ...e process water is drawn from the brine tank and flushed through the system At the end of the cycle water is put back into the brine tank in order for the salt to dissolve ready for the next time the...

Page 4: ...r facility and or an outside tap The distance between the drain and the Softener should be as short as possible Ensure that both the drain and overflow will not freeze or reach a temperature above 40...

Page 5: ...22mm pipework position Typical Softener Installation Valve Configuration when using a 15mm fitting kit Typical softener installation valve configuration when using a 22mm fitting kit pipework position...

Page 6: ...water pressure of 40 psi Overflow Connection The overflow connection is the white hose spigot on the rear or side of the cabinet The overflow must be run downhill through an outside wall without kinks...

Page 7: ...y programming instructions that apply to your particular machine and perform a manual regeneration A manual regeneration is performed at this stage to allow you to confirm that the unit has no leaks f...

Page 8: ...ill show you the total amount of treated water the softener can achieve before regeneration If you need to change this amount you will need to do follow this calculation Softener resin capacity x 50 f...

Page 9: ...mption and the size of property number of bathrooms The salt level should always be above the water level Check there is no sign of damage or leaks Programming the valve in case of memory loss Should...

Page 10: ...time on each option by using the up and down arrows to select the minutes and seconds required Once finished press RETURN until the main display shows Step 2 System set up Change override days default...

Page 11: ...of the layout applicable to your property Troubleshooting You will find fitting videos which will assist in your water softener installation and advice and information on common problems that can airs...

Page 12: ...door delivery service Repeat ordering so you never run out of salt Water softeners Water filters under sink and whole house filters Reverse Osmosis systems domestic and commercial Our Made in the UK h...

Reviews: