8
EM
-
Ocean Water Softener
Programming
Programming the Valve.
The valve is pre programmed with the exception of the time of day.
When plugging the softener in initially, the screen will display the valve model
‘
F79
’.
After 10 seconds, the
valve will automatically show the set time of day screen.
Set Time of Day.
Adjust the hours by pressing the ˄ & ˅ buttons, press
CONFIRM
, then adjust the minutes by pressing ˄ & ˅
buttons, press
CONFIRM
and this will return you to the main screen.
Capacity setting.
The capacity will have a default setting based on 300ppm hardness. If you wish to change this, please follow
these instructions:
Using the ˄ & ˅ buttons, scroll to
‘
Advanced Settings
’.
Press
CONFIRM,
scroll down to
‘
Set residual water
’
and press
CONFIRM
. This will show you the total amount of treated water the softener can achieve before
regeneration.
If you need to change this amount, you will need to do follow this calculation –
Softener resin capacity x 50
for example:
10X50 = 1.66m3
Hardness
30
Press
CONFIRM
when finished
Commissioning the Softener
With the softener fully plumbed in and the valve programmed, you can start the commissioning;
Regeneration
When the softener is fully functional, the regeneration will happen at the pre
-
set time (see
programming the valve section on page 8).
To initiate an immediate regeneration press and hold the
RETURN
button until the valve motor starts
to turn. If, during a regeneration cycle you need to skip through the cycle, this can be done in the
following way:
To skip to the next stage quickly press the
RETURN
button and this will take it to the next stage of
the regeneration, this can be repeated to get to the end of the regeneration cycle.