General maintenance
If the product is installed in public spaces and is
accessible to everyone, observe local and national
requirements (e.g. Norway NEK400 part 6.1) in addition to
the procedures below.
— Ensure that the charger does not have any signs of
mechanical damage.
— Visually inspect the Type 2 socket for wear and tear
at regular intervals according to local regulations. If
the pins are discoloured or damaged, please contact
your authorised electrician.
Cleaning
The charger does not require cleaning to operate
properly. Nevertheless, if the product needs to be
cleaned for cosmetic reasons, this is possible.
— Use a damp cloth and an all-purpose household
cleaner. Avoid using strong chemicals that contain oil
or alcohol, as this may discolour the plastic.
— Do not use running water or high pressure water jets.
Insulation testing (authorised electrician only)
When carrying out periodic insulation testing
of a charging circuit, it is recommended that
you remove the Chargeberry from its backplate
before measuring between all phases joined
together towards earth. Testing the circuit
insulation with the Chargeberry installed in
the backplate may damage the electronics or
impact the reading negatively.
Maintenance
Practical details
Warranty
The device is free from material defects and is in
accordance with laws and regulations for consumer
protection in the country where the product is
purchased. All correctly installed Easee hardware is
covered by our 3 years limited warranty. If your charger
needs to be repaired within this warranty period, please
contact your Easee supplier. Further information can be
found at
easee.support
.
Safety
The product shall be installed according to local
regulations for low voltage electrical installations.
The product is designed and tested according to the
EN 61851 standards for electric vehicle conductive
charging system. It includes a built-in RCD able to safely
break the circuit in the event of a 30 mA AC or 6 mA DC
fault in accordance with IEC 61008 and IEC 62955.
Standards
Hereby, Easee AS declares that this product, Easee EV
Charging Robot E01-CB, is in compliance with the Low
Voltage Directive 2014/35/EU, Radio Equipment Directive
2014/53/EU, EMC Directive 2014/30/EU and RoHS
Directive 2011/65/EU.
The full text of the EU Declaration of Conformity is
available at the following internet address: