background image

Measurement  

in mm

General

Product (mm): H: 110 x W: 110 x D: 27.5
Packaging (mm): H: 130 x W: 130 x D: 39
Operating temperature: -20 °C to +50 °C
Weight: 95 g
Material: PC/ABS
Colour: White
IP degree: IP40
Power supply: 5-32 V DC 100 mA
RJ12 connector
Integrated magnets for attaching the 
product to metal surfaces or to wall 
mount plate

Cabling

Cable length: 1.5 m
RJ12 custom made cable¹
Can be extended using an extension cable 
up to 15 m

Technical

Specifications

H:110

D:27.5

W:110

The product contains

Equalizer

Cable

(custom made)

Wall mount plate

Max transmitted power 

Radio: 

25 mW at 863–870 MHz.

WiFi: 

50 mW at 2.4–2.472 GHz.

Connectivity

Easee Link RF™ and Wifi

2

 P1 smart meter 

communication
Modbus RTU (RS-485) connection to 
energy meter

3

Monitor power consumption with 
the Easee App
RFID / NFC reader

RJ11/RJ12 uses the same connector. 

WiFi is required for normal operation and for future software 

updates. When offline or unstable, it will use Easee Link RF

TM

 as 

backup in small installations with one primary charger. Easee 
Link RF

TM 

via radio may be limited by walls, concrete or other 

obstacles.

Only for supported meters.

DISCLAIMER: THIS DOCUMENT IS A DRAFT, AND PROVIDED AS A COURTESY. PLEASE DO NOT SHARE.

Summary of Contents for 90501UK

Page 1: ...optimizes your charging It prevents the main fuse from turning off due to overload and allows the user to use all available electricity to charge their car by communicating with the Easee Charging Rob...

Page 2: ...see chargers through Easee LinkTM or WiFi Monitor the power consumption in your building through the Easee app Disclaimer The installation of the Equalizer home package must be done according to exist...

Page 3: ...Cable custom made Wall mount plate Max transmitted power Radio 25 mW at 863 870 MHz WiFi 50 mW at 2 4 2 472 GHz Connectivity Easee Link RF and Wifi2 P1 smart meter communication Modbus RTU RS 485 conn...

Page 4: ...D 66 Input voltage 180 264V 47 63 Hz N L Output voltage 24V dc 5 Effect 30VA 1 25A electricity limit 2 5A MTBP 50000 h at 70 load at 25 C IP classification IP40 Running temperature 10 C 45 C Double i...

Page 5: ...t Rogowski Coils must be fitted in the correct order to read incoming power line Accessibility to WiFi to facilitate latest software updates for the Equalizer Fuse 3 pool 10A not included Installation...

Page 6: ...n the backplate and complete the site Download the Easee Installer App by scanning this QR code At Site Overview Add Equalizer WiFi information Scan Equalizer with your phone s NFC reader Connect Equa...

Page 7: ...password it can t be an open Wi Fi Connected on 2 4 GHz Wi Fi 5 GHz does not work Firewalls or login portals blocking internet access Make sure that the Equalizer has good coverage for Wi Fi Change lo...

Page 8: ...r App go to Site Overview Site Structure Equalizer you can click on the product card and get the same visual image of the Equalizer that the customer gets via their Easee app Control Here you can conf...

Page 9: ...rging box until it lights up green Reconnect the Equalizer to the metre reader If the Equalizer does not appear in the Easee Installer App the signal is too weak Reposition Wi Fi or Equalizer to get a...

Page 10: ...er reader Red consistent Fault Troubleshooting Do you require assistance Make sure to have the serial number available for the Easee Home and Equalizer to receive more rapid assistance Easee Customer...

Page 11: ...DISCLAIMER THIS DOCUMENT IS A DRAFT AND PROVIDED AS A COURTESY PLEASE DO NOT SHARE Wiring scheme Power meter Power supply 24 V DC...

Page 12: ...publication may be reproduced or transmitted in any form or by any means electronic or mechanical including but not limited to copying recording retrieving data or computer networks without the writt...

Reviews: