Item
Symbol
Value
Unit
Item
Symbol
Value
Unit
Rated heat output (*)
Prated
12
kW
Seasonal space heating
energy efficiency
ηs
127
%
Tj = -7
℃
Pdh
10.9
kW
Tj = -7
℃
COPd
2.02
-
Tj = 2
℃
Pdh
7.0
kW
Tj = 2
℃
COPd
3.05
-
Tj = 7
℃
Pdh
4.2
kW
Tj = 7
℃
COPd
4.49
-
Tj = 12
℃
Pdh
2.5
kW
Tj = 12
℃
COPd
5.97
-
Tj = bivalent temperature
Pdh
10.9
kW
Tj = bivalent temperature
COPd
2.02
-
Tj = operating limit
Pdh
10.3
kW
Tj = operating limit
COPd
1.73
-
For air-to-water heat pumps:
Tj = -15
℃
Pdh
-
kW
For air-to-water heat pumps:
Tj = -15
℃
COPd
-
-
Bivalent temperature
T
biv
-7
°C
For air-to-water heat pumps:
Operation limit temperature
TOL
-10
°C
Cycling interval capacity for
heating
P
cy ch
-
kW
Cycling interval efficiency
COP
cy c
Degradation co-efficient (**)
C
dh
0.9
--
Heating water operating limit
temperature
W
TOL
60
°C
Off mode
P
of f
0.019
kW
Standby mode
P
sb
0.019
kW
Thermostat-off mode
P
to
0.078
kW
Crankcase heater mode
P
ck
0.014
kW
Sound power level, indoors/
outdoors
L
WA
45 / 67
dB
Annual energy consumption
Q
HE
7833
kWh
Declared load profile
Water heating energy
efficiency
η
wh
-
%
Daily electricity consumption
Q
elec
-
kWh
Daily fuel consumption
Q
f uel
-
kWh
Annual electricity consumption
AEC
-
kWh
Annual fuel consumption
AFC
-
GJ
Contact details
Technical parameters
variable
Capacity control
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh,
and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
Air-to-water heat pump:
Declared capacity for heating for part load at indoor temperature 20 °C
and outdoor temperature Tj
Declared coefficient of performance or primary energy ratio for part load at
indoor temperature 20 °C and outdoor temperature Tj
Power consumption in modes other than active mode
Supplementary heater
-
For heat pump combination heater:
For air-to-water heat pumps:
Rated air flow rate, outdoors
Other items
For water- or brine-to-water
heat pumps: Rated brine or
water flow rate, outdoor heat
exchanger
_
-
m
3
/h
_
6500
m³/h
Electrical
Rated heat output (**)
Psup
kW
Outdoor unit: ETH-10VB
Indoor unit: ETH-KH160
YES
NO
NO
NO
NO
Model(s):
Water-to-water heat pump:
Brine-to-water heat pump:
Low-temperature heat pump:
Equipped with a supplementary heater:
Heat pump combination heater:
Type of energy input
Parameters are declared for medium-temperature application.
YES
2.0
-
-
Declared climate condition:
AVERAGE
EAS ELECTRIC
Pol. Industrial San Carlos, Parcela 13 03370 Redován (Alicante)
www.easelectric.es
V.2
2